Loading...
HomeMy WebLinkAboutCONCRETE TEST - 21-00119 - Adams Elementary School - AdditionFile Name 21020CP09072021YK 345b909c5362d83b-1631021239447 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 21020 Cumulative Test Load Amount: 5.5 Project Name: Adam's Elementary Test Location: Interior slab around few spots inside the building Client: Madison School District Admixtures: Required 28 day Strength (psi): 3,500.0 Contractor: Mills Concrete Supplier: Idaho Materials Mix Number: 3325605 Ticket #: 9977 Date: 09/07/2021 Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 07:00 AM 9977 Interior slab around few spots inside the building 45 146.14 1.40 NA 62 3.75 6 max Remarks: I left the cooler along the wall on the east side of the extension building. Tested By: Yannick Kabwika Signature: Date: 09/07/2021 Reviewed By: E. Vail Signature: Date: 09/07/2021