HomeMy WebLinkAboutPLANS - 21-00707 - 85 Oak Ave - Solar PanelsCONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT PROJECT INFORMATION, VICINITY MAP www.bigdogenergy.comPV - 18/30/2021 MSPSUBACDCSLCMINVJBCBFMCMAIN SERVICE PANELSUB SERVICE PANELAC DISCONNECTDC DISCONNECTSOLAR LOAD CENTERMONITORING METERINVERTERJUNCTION BOXCOMBINER BOXFLEXIBLE METALLIC CONDUIT(E)(N)EXTINTEMTRMTVOCVMPISCNTSEXISTINGNEWEXTERIORINTERIORELECTRICAL METALLIC TUBINGRIGID METALLIC TUBINGVOLTAGE OPEN CIRCUITVOLTAGE AT MAX. POWERSHORT CIRCUIT CURRENTNOT TO SCALEIMPCURRENT AT MAX. POWERALL WORK TO COMPLY WITHTHE FOLLOWING CODE:NEC 2017 CODEIBC 2018 CODEPV-1 PROJECT INFORMATION,VICINITY MAPPV-2 SITE PLAN, AERIAL VIEWPV-3 ELECTRICAL LINE DIAGRAMAND NOTESPV-4 REQUIRED SIGNAGEADDITIONAL NOTESPLAN SET LEGENDABBREVIATIONSPROJECT INFORMATIONVICINITY MAPAPPLICABLE CODESSHEET INDEX30-340W PANASONICPHOTOVOLTAIC MODULES1-10000W SOLAREDGESYSTEM SIZE: 10.2KW DC STCARRAY AREA: 210SFJOHN MICHELSEN85 OAK AVEREXBURG, ID 83440208-516-6273JOHN MICHELSEN 85 OAK AVE REXBURG, ID 83440 208-516-6273 Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ SCALE: NTS JOB NO.: 12140 ALL CONDUIT TO RUN ON EXTERIOROF HOUSE UNLESS OTHERWISE NOTEDOCCUPANCY: R-3CONSTRUCTION TYPE: VBUNSPRINKLERED1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2. ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6. ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8. DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9. THE PROJECT HAS BEEN DESIGNED TO WITHSTAND AMINIMUM 110 MPH WIND LOAD.10. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITYIS OBTAINED.11. IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12. EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13. A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14. PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15. GFCI PROTECTION IN INVERTER.9/1/2021 WITHIN 3'OF METERCONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SITE PLAN, AERIAL VIEW www.bigdogenergy.comPV - 2SITE PLANAERIAL VIEWSCALE: NTSSCALE: NTSTOTAL # OF PANELS30ABBREVIATIONSINVMSPACINVERTERMAIN SERVICE PANELAC DISCONNECTMTRMETERBig Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ROOF TYPE:4/12 SHINGLE8/30/2021 N3'-0 WALKWAY18" CLEARJOHN MICHELSEN 85 OAK AVE REXBURG, ID 83440 208-516-6273 SCALE: NTS JOB NO.: 121409/1/2021 10,200W TOTAL SOLAR ARRAY30 PANASONIC 340W PANELSARRAY 12 STRINGS OF 15 MODULES CONNECTED IN SERIES @ INVERTERNN GD200ACNGNNG L1L134L2L2_~B215 MODULES IN SERIESEMPPT 2STRING 1-2TILT: 28°AZIMUTH:200°ONE PER PANELAELECTRICAL EQUIPMENT CALLOUTSSOLADECK MODEL 0783-41 JUNCTIONBOX/ROOF PENETRATION, 600V10.0kW INVERTER UNGROUNDEDSOLAREDGE SE10000H-US(240V) INVERTER240VAC, 42A, NEMA 3R, UL LISTED,(W/ INTEGRATED DC DISCONNECT)WITH INTEGRATED GFP, W/INTEGRATED AFPSQUARE D SAFETY SWITCH, #H222NRBP/N 3112 600 VDC,60A, NEMA 3R, FUSIBLE,10,000 AIC, UL, NEMA, CSA, NOM CERTIFIEDW/60A FUSES200A MAIN SERVICE PANEL(W/ BIDIRECTIONAL UTILITY METER)SOLAREDGE OPTIMIZER P370 ONE PER PANELBDA123WIRE AND CONDUIT CALLOUTS(2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMT/FMC(2) #6 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMT(2)#6 AWG THWN-2(1)#8 AWG THWN-2 GND IN 34" EMTCE1MPPT 1MPPT 3MODULE:PANASONIC 340WVoc= 71.3 V Isc= 6.13AVmp= 59.7V Imp=5.7AALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHCODE AND THE MANUFACTURER'S INSTALLATIONINSTRUCTIONS.TAP 27415 MODULES IN SERIESA12EONE PER PANELELECTRICAL SINGLE LINE DIAGRAMCONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SINGLE LINE DIAGRAM www.bigdogenergy.comPV - 3SCALE: NTSELECTRICAL NOTESRACKING & MODULES ARE GROUNDED VIA ACONTINUOUS #6AWG COPPER CONDUCTORCONNECTED W/ WEEBS - MODULES ARE FACTORYPROVIDED W/ 2 THREADED HOLES TO FACILITATELANDING OF THE LUGSALL EQUIPMENT SHALL BE PROPERLY GROUNDED ANDBONDED IN ACCORDANCE WITH ARTICLE 250.ALL CIRCUITS CONNECTED TO MORE THAN ONESOURCE SHALL HAVE OVERCURRENT DEVICESLOCATED SO AS TO PROVIDE OVERCURRENTPROTECTION FROM ALL SOURCES 690.9 (A)Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 8/30/2021 1. PV ARRAYS ARE PER SINGLE LINE.2. PV ARRAY WIRING TO JUNCTION IS #10 AWG USE 2 W/FIELD INSTALLED MC CONNECTORS TO INTERFACE W/MODULES.3. PV ARRAY COMBINER/JUNCTION BOX PROVIDESTRANSITION FROM ARRAY WIRING TO CONDUITWIRING.4. USE UFER GROUND ELECTRODE SYSTEM FROMINVERTER TO EXISTING MAIN SERVICE GROUNDELECTRODE PER N.E.C. 250.58.5. GROUND ELECTRODE CONDUCTOR FROM INVERTERTO GROUND ELECTRODE TO BE MINIMUMPROTECTION OF BARE ARMOR SHEATHED CABLE FORALL CONDUCTOR SIZES.6. ALL GROUND CONNECTED TO MAIN SERVICE GROUNDIN MAIN SERVICE PANEL.7. CONNECTORS SHALL BE POLARIS OR EUROSTRIP ITCONNECTORS.8. INVERTER SHALL BE PER SINGLE LINE, SEE ATTACHEDCUT SHEET.9. INVERTER IS PER SINGLE LINE.10. AC DISCONNECT SHALL BE PER SINGLE LINE.11. EQUIPMENT GROUNDING CONDUCTORS ON AC ANDDC SIDE SIZED ACCORDING TO N.E.C. 690.12. POLE OF PV ARRAY REFERENCED TO GROUND AT THEINVERTER IN SINGLE LINE.13. ALL CONDUCTORS SHALL BE 600V, 90C STANDARDCOPPER. ALL CONDUCTORS IN CONDUIT SHALL BETHWN-2.14. MAXIMUM DC VOLTAGE DROP SHALL BE 2.5%15. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESSOTHERWISE NOTED.16. ALL WORK TO COMPLY WITH NEC 2017 CODE.17. DC ARRAY CONDUCTORS ARE TO REMAIN OUTSIDEOF BUILDING PRIOR TO FUSIBLE COMBINER BOX ORFUSIBLE DC DISCONNECT MEANS.18. EXACT CONDUIT RUN LOCATIONS SUBJECT TOCHANGE.19. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROMMODULES) DEAD LOAD CONTRIBUTED FROM SOLARARRAY.20. ARC FAULT INSTALLED AT INVERTER OR IN COMBINERBOX.21. DC GROUND FAULT PROTECTION INTEGRATED ININVERTER.22. POINT OF CONNECTION BREAKER TO BE LOCATEDOPPOSITE END OF BUSBAR FROM MAIN UNLESSOTHERWISE NOTED.23. ANY UNDERGROUND WIRING METHODS WILL COMPLYWITH NEC 300.5(J), 300.7(B), 352.44, AND OTHERSECTIONS OF CHAPTER 3 AS APPLICABLE.24. ANY EXPOSED PVC CONDUIT SHALL COMPLY WITHNEC 352.1025. ALL PV SYSTEM DC CIRCUITS RUN INSIDE A BUILDINGSHALL BE CONTAINED IN A METAL RACEWAY INACCORDANCE TO NEC 690.31(G)26. COMPLIES WITH 705.12(B)(2)(3)(B)27. SUPPLY SIDE CONNECTION WITH LISTED INSULATIONPIERCING CONNECTORS IN ACCORDANCE WITH705.12(A) AND 230.8228. CONNECTION AT PANEL SECONDARY SERVICELOCATIONJOHN MICHELSEN 85 OAK AVE REXBURG, ID 83440 208-516-6273 SCALE: NTS JOB NO.: 12140 CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT REQUIRED SIGNAGE www.bigdogenergy.comPV - 4REQUIRED SIGNAGE8/30/2021 Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 14" HIGHLETTERING PER NEC 690-17.2. LABEL FOR SOLAR AC DISCONNECT:FIRE DEPARTMENT REQUIRED SIGNAGE3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 38" HIGHLETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS,WHITE ON RED BACKGROUND AND A REFLECTIVE, WEATHER RESISTANTMATERIAL.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING:WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALS ON BOTHTHE LINE AND LOAD SIDES MAY BE ENERGIZED INTHE OPEN POSITION."SOLAR AC DISCONNECT"WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLAR ELECTRIC SYSTEMTHE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:CUSTOMER OWNEDONSITE POWER GENERATIONSYSTEM DISCONNECT5. LABEL INSTALLATION AT INTERCONNECT BREAKER:WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE.ALL SIGNAGE MUST BE PERMANENTLY ATTACHEDAND BE WEATHER RESISTANT/SUNLIGHT RESISTANT AND CANNOT BEHAND-WRITTEN.NEC 110.21(B)6. REFLECTIVE PLACARD AT SERVICE STATING:7. AT PV DISCONNECT SWITCH AS REQUIRED PER NEC 690.56(C)(3):8. THE FOLLOWING SIGN MUST BE PROVIDEDON THE OUTSIDE (OR WITHIN 3' OF) THE SERVICEPANELBOARD, AS REQUIRED PER NEC 690.56(C)(1):9 SIGNAGE REQUIRED AT SERVICE PANELBOARD PER NEC 690.54:10 SIGNAGE REQUIRED AT STRING INVERTER PER NEC 690.53:PHOTOVOLTAIC SYSTEMEQUIPPED WITHRAPID SHUTDOWNRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMTOTAL RATED AC AMPS: 60ASYSTEM AC VOLTAGE: 240VDIRECT CURRENT PHOTOVOLTAIC SOURCESYSTEM DC VOLTAGE: 240VMAX DC CIRCUIT CURRENT: 42AMAX DC CURRENT PER OPTIMIZER: 15AJOHN MICHELSEN 85 OAK AVE REXBURG, ID 83440 208-516-6273 SCALE: NTS JOB NO.: 12140 N340/N335 Quality and Reliability Panasonic’s vertical integration, 21 years of experience manufacturing HIT® and 20 internal tests beyond those mandated by current standards provides extreme quality assurance. Higher Efficiency 20.3% Enables higher power output and greater energy yields. HIT® provides maximum production for your limited roof space. Enhanced Frame Design A new 40mm frame increases durability and strength, being able to handle loads of up to 5400Pa. Also, the water drainage system gives rain water and snow melt a place to go, reducing water stains and soiling. Less dirt on the module means more sunlight getting through to generate power. Low Degradation HIT “N-type” cells result in extremely Low Light Induced Degradation (LID) and zero Potential Induced Degradation (PID) which supports reliability and longevity. This technology reduces annual degradation to 0.26% compare to 0.70% in conventional panels, guaranteeing more power for the long haul. Our competitive advantages High Efficiency at High Temperatures As temperature increases, HIT® continues to perform at high levels due to the industry leading temperature coefficient of -0.258% /C. No other module even comes close to our temperature characteristics. That means more energy throughout the day. 25 Year Product and Performance Warranty** Industry leading 25 year product workmanship and performance warranty is backed by a century old company- Panasonic. Power output is guaranteed to 90.76% after 25 years, far greater than other companies. Panasonic’s unique heterojunction technology uses ultra-thinamorphous silicon layers. These thin dual layers reduce losses,resulting in higher energy output than conventional panels. Advanced bifacial cell designed for increased energy output.The cell utilizes sunlight reflected back from the rear sidematerial which captures more light and converted into energy. n-type crystalline siliconDouble-sided textured surface i-type amorphous layer Amorphous layer Transparent electrode (TCO) Lattice-type electrodes Finger Tab These amorphous silicon layersreduces the recombination ofelectrons to minimum level. Electrodes Ultra-thin amorphous silicon layer HIT® is a registered trademark of Panasonic Group + CAUTION! Please read the installation manual carefully before using the products. Used electrical and electronic products must not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points in accordance with your national legislation. Panasonic Eco Solutions of North America Two Riverfront Plaza, 5th Floor, Newark, NJ 07102panasonicHIT@us.panasonic.com business.panasonic.com/solarpanels All Rights Reserved © 2018 COPYRIGHT Panasonic Corporation Specifications are subject to change without notice 08/2018 RS181058DS_1.19 DEPENDENCE ON IRRADIANCE Reference data for model: VBHN330SA17(Cell temperature: 25°C) PERFORMANCE WARRANTY 97% 90.76% 80% More powerover 25 years N340/N335 ELECTRICAL SPECIFICATIONS Model VBHN340SA17 VBHN335SA17 Rated Maximum Power (Pmax)¹340W 335W Maximum Power Voltage (Vpm) 59.7V 59.4V Maximum Power Current (lpm)5.7A 5.65A Open Circuit Voltage (Voc) 71.3V 71V Short Circuit Current (lsc) 6.13A 6.08 Temperature Coefficient (Pmax) -0.258%/°C -0.258%/°C Temperature Coefficient (Voc) -0.17V/°C -0.17V/°C Temperature Coefficient (lsc) 3.37mA/°C 3.34mA/°C NOCT 44.0°C 44.0°C CEC PTC Rating 321.3 316.5 Cell Efficiency 22.85%22.52% Module Efficiency 20.3%20% Watts per Ft.²18.9W 18.6W Maximum System Voltage 600V 600V Maximum Series Fuse 15A 15A Warranted Tolerance (-/+)+10%/-0%*+10%/-0%* MECHANICAL SPECIFICATIONS Model VBHN340SA17 Internal Bypass Diodes 4 Bypass Diodes Module Area 18.02 Ft.² (1.67m²) Weight 41.89 Lbs (19kg) Dimensions LxWxH 62.6x41.5x1.6 in. (1590x1053x40 mm) Cable Length +Male/-Female 40.2/40.2 in. (1020/1020 mm) Cable Size / Type No. 12 AWG / PV Cable Connector Type2 Multi-Contact® Type IV (MC4™) Static Wind / Snow Load 112 PSF (5400Pa) Pallet Dimensions LxWxH 63.7x42.2x46.4 (Malaysia) 65.3x43.7x48.5 in. (USA) Quantity per Pallet / Pallet Weight 24 pcs./1049 Lbs. (476 kg) Quantity per 40' Container 672 pcs. Quantity per 20' Container 288 pcs. OPERATING CONDITIONS & SAFETY RATINGS Model VBHN340SA17 Operating Temperature -40°F to 185°F (-40°C to 85°C) Hail Safety Impact Velocity 1" hailstone (25mm) at 52 mph (23m/s) Safety & Rating Certifications UL 1703, cUL Certified by UL LLC.CEC, FSEC, ISO9001 UL 1703 Fire Classification Type 2 Limited Warranty 25** Yrs Workmanship and Power Output (Linear)*** Manufacturing Locations USA and Malaysia NOTE: Standard Test Conditions: Air mass 1.5; irradiance = 1000W/m²; cell temp. 25°C * Maximum power at delivery. For guarantee conditions, please check our guarantee document. ** Installation need to be registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year Product workmanship. Otherwise, Product Workmanship will be only fifteen (15) years. *** 1st year 97%, after 2nd year 0.26% annual degradation to year 25. 1 STC: Cell temp. 25°C, AM1.5, 1000W/m²2 Safety locking clip (PV-SSH4) is not supplied with the module. NOTE: Specifications and information above may change without notice. DIMENSIONS Unit: inches (mm) 13.514.9 *Please refer to the Installation Manual for different loads + INVERTERSwww.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT  Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-3 -3 ---Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V -16 -24 ---A Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 AUtility Monitoring, Islanding Protection, C o u nt r y C o nfi g u ra b l e T h re s h o l d s Yes INPUT  Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --- Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V -9 -13.5 --- Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 WADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS  AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C option)(4)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. POWER OPTIMIZERSolarEdge Power Optimizer Module Add-On For North America P320 / P370 / P400 / P405 / P505 Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY- SWEDEN-SOUTH AFRICA-POLAND-CZECH REPUBLIC OPTIMIZER MODEL (typical module compatibility) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) P505 (for highercurrent modules) INPUT Rated Input DC Power(1)320 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 83 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x 152 x 50 / 5 x 5.97 x 1.96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(2) Output Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge SolarEdge Power Optimizer Module Add-On for North America P320 / P370 / P400 / P405 / P505 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)(4) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) P320, P370, P400 8 10 18 P405 / P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(5) Maximum Power per String 5700 (6000 with SE7600H-US, SE10000H-US) 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2018/V01/ENG NAM. Subject to change without notice. (3) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf.(4) It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string.(5) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement snapnrack.comUltra RailIndustry leading Wire Management SolutionsSingle Tool Installation Mounts available for all roof typesAll SnapNrack Module Clamps & Accessories are compatible with both raiil profi lesStart Installing Ultra Rail TodayUR-40UR-60The Ultimate Value in Rooftop SolarSolar Mounting Solutions© 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.comSnapNrack_Ultra Rail Sales Brochure_v.1.4SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety.Quality. Innovative. Superior. Unparalleled Wire Management• Open rail channel provides room for running wires resulting in a long-lasting quality install• Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps• System is fully bonded and listed to UL 2703 Standard© 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.comSnapNrack Ultra Rail SystemA sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install.The Entire System is a Snap to Install• New Ultra Rail Mounts include snap-in brackets for attaching rail• Compatible with all the SnapNrack Mid Clamps and End Clamps customers love• Universal End Clamps and snap-in End Caps provide a clean look to the array edgeHeavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le-specifi c rail splice and end cap• All existing mounts, module clamps, and accessories are retained for the same great install experience snapnrack.comCertification DetailsSnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Grounding/Bonding, Mechanical Loading, and Fire Classification.The Ultra Rail system has been designed in compliance with UL Standard 2703 Section 9.1 Exception, which permits accessible components that are not part of the fault current ground path to not be electrically bonded to the mounting system (e.g. roof attachments, array skirt, etc.). For more details on the integrated grounding functionality see the Grounding Specifications section.This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. See the Grounding Specifications for the list of modules tested with the Ultra Rail system for integrated grounding.Ground Lugs have been evaluated to both UL 467 and UL 2703 Listing requirements.Ultra Rail has been listed with a number of Module Level Power Electronic (MLPE) devices. A complete list can be found in the Grounding Specifications section.The mounting system Bonding Listing is only valid when installed with a Non-Separately Derived PV system. The PV system is required to have a direct electrical connection to another source, such as connecting to the grid via a grid interactive inverter.SnapNrack recommends that bare copper never come into contact with aluminum.Grounding/BondingThe Ultra Rail system is Listed for mechanical loading for different load ratings depending on the mounting configuration and PV module installed. For more details on the mechanical loading details see the Mechanical Loading Specifications section.SnapNrack engineered systems should only be used with SnapNrack components and hardware. Any application outside of those specified in this Installation Manual and the Structural Engineering Report may void the warranty and structural certification could become invalid.If the module clamps have been engaged and need to be loosened and reengaged, SnapNrack recommends moving the module frame 3mm to engage the bonding pin in a new location.The UL Listing covers mechanical load ratings for the various span lengths, module orientations and positive, negative, and side load ratings. These values can be found in the Mechanical Loading Specifications section.SnapNrack recommends a periodic re-inspection of the completed installation for loose components, loose fasteners, and any corrosion, such that if found, the affected components are to be immediately replaced.Mechanical LoadingFireThe Ultra Rail system has been evaluated for a Class A System Fire Classification for a Steep-Sloped Roof (≥ 2:12 pitch) using Type 1 and Type 2 modules. In order to maintain the System Classification, modules are clamped to the mounting rails between 0 and 12 inches from the top and bottom edges of the module.The Ultra Rail system has been evaluated for a Class A System Fire Classification for a Low-Sloped Roof (< 2:12 pitch) using Type 1 and Type 2 modules. In order to maintain the System Classification, modules are clamped to the mounting rails be-tween 0 and 16.3 inches from the top and bottom edges of the module.The optional Array Skirt accessory has also been evaluated and the Ultra Rail system will maintain the Class A System Fire Classification detailed above if installed with the Skirt.Because the system was tested at 5 inches above the test roof fixture Ultra Rail can be installed without any height restric-tions and will maintain the Class A System Fire Classification. See Rail Installation section for potential module-specific height restrictions due to module temperature. snapnrack.com56Grounding SpecificationsUltra Rail has been tested with the following UL Listed modules:The Ultra Rail System employs top-down clamps which have been evaluated for frame-to-system bonding, at specific mounting torques and with the specific modules listed below. The system has been assessed to a maximum Over-Current Device (OCD) protection level of 20 amps. The UL file number is included in parentheses below.Hyundai Heavy Industries Co Ltd (E325005) - HiS-MXXXRG Series where XXX is 235 to 275; HiS-SXXXRG where XXX is 245 to 295; HiS-SXXXRW where XXX is 250 to 265; HiS-MXXXMG where XXX is 210 to 270; HiS-SXXXMG where XXX is 220 to 275. All may be followed by the suffix BK or blank. Jinko Solar (E362479) - JKMXXXP-60, JKMXXXPP-60, JKMXXXP-60-V, JKMXXXP-60-J4, JKMXXXP-60B-J4 where XXX is 200 to 290; JKMXXXP-72, JKMXXXPP-72, JKMXXXP-72-V, JKMXXXPP-72-V where XXX is 250 to 360; JKMXXXM-60 where XXX is 200 to 305; JKMXXXM-72 where XXX is 250 to 365; JKMXXXM-60L where XXX is 305-325; JKMXXXM-60HBL (310-330); JKMXXXM-72L-V( 370-390); JKMXXXM-72HL-V (380-400). Kyocera (E467150) - KU-60 1000 V Series - KUXXX, where XXX is 250 to 275, followed -6BCA, -6BFA, -6BPA, -6DCA, -6DFA, -6DPA, -6MCA, -6MPA, -6XCA, -6XPA, -6ZCA, -6ZPA, -6ZPB, -6ZCB, -6ZPC, -6ZCC, -6ZPD, -6ZCD, -6ZPE, 6ZCE, -6MPC, -6MCC, -6MPB or -6MCB; KU-80 1000 V Series - KUXXX, where XXX is 315 to 335, followed by -8BCA, -8BFA or -8BPA.LG (E329725) – LGXXXQ1C-A5 where XXX is 340 to 385; LGXXXQ1K-A5 where XXX is 315 to 375; LGXXXN1C-V5 where XXX is 320 to 350; LGXXXN1K-V5 where XXX is 320 to 340; LGXXXQ1C-V5 where XXX is 340 to 375; LGXXXQ1K where XXX is 350 to 365.Panasonic (E181540) – VBHNXXXSA16 where XXX is 320 to 335; VBHNXXXKA01 and VBHNXXXKA02 where XXX is 310 to 325, VBHNXXXKA03 and VBHNXXXKA04 where XXX is 310 to 325; VBHNXXXSA17 and VBHNXXXSA18 where XXX is 325 to 335; VBHNXXXSA17E where XXX is 325 to 330.REC Solar AS (E308147) - RECXXX, where XXX is 214 to 270, all may be followed by PE, PE(BLK), PE-US, PE-US(BLK), PEQ2 or PEQ3.Renesola Jiangsu Ltd (E312637) - JCXXXM-24/Bb Series where XXX is 200 to 270; JCXXXM-24/BBh Series where XXX is 235 to 270.Suniva Inc (E333709) - MVX-XXX-60-5-YYY where XXX is 235 to 265 and YYY is 701 or 7B1; OPT-XXX-60-4-YYY where XXX is 250 to 275 and YYY is 800 or 8B0.*Sunpower (E246423)- Gen 3 or Gen 5 frame models SPR-XYY-### where YY represents numbers 18, 19, 20, 21 or 22, and ### represents any number from 365 to 310 and 274 to 233; Gen 3 or Gen 5 frame models SPR-EYY-### where YY represents numbers 18, 19, 20, 21 or 22, and ### represents any number from 345 to 285 and 250 to 225.Talesun Solar (E359349) – TP660P-XXX where XXX is 235 to 285; TP660M-XXX where XXX is 240 to 300; TP672P-XXX where XXX is 280 to 345; TP672M-XXX where XXX is 290 to 360; TP672M-XXX where XXX is 360; TP660M-XXX where XXX is 295-300.GROUNDING MARKING DETAILSAll components included in the Ultra Rail UL 2703 Listing for grounding/bonding are packaged and marked with the UL logo, SnapNrack File E359313, and “PV Mounting System”The SnapNrack Ground Lug is marked with the ground symbolIlsco Ground Lugs have green colored set screws or bolts to indicate connection to the grounding electrode conductorsnapnrack.com57Grounding SpecificationsTalesun Solar (E349638) – TP660P-XXX where XXX is 210 to 255; TP660M-XXX where XXX is 215 to 260; TP672P-XXX where XXX is 260 to 300; TP672M-XXX where XXX is 270 to 310; all may be followed by “B”.Trina Solar Ltd (E306515) – TSM-XXXPA05, TSM-XXXPA05.05, TSM-XXXPA05.08, where XXX is 215 to 260; TSM-XXXPD05, TSM-XXXPD05.05, TSM-XXXPD05.08 where XXX is 240 to 280; TSM-XXXPD05.08D where XXX is 245 to 275; TSM-XXXXDD05A(II), TSM-XXXDD05A.05(II), TSM-XXXDD05A.08(II) where XXX is 260 to 300. All may be followed by Black or White.Yingli Energy (China) Co Ltd (E320066) – YLXXXP-29b where XXX is 215 to 260; YLXXXA-29b where XXX is 220 to 255.NRTL Listed PV Modules:Boviet Solar - BVM6610P-XXX where XXX is 225 to 275; BVM6610M-XXX where XXX is 235 to 280; BVM6612P-XXX where XXX is 270 to 330; BVM6612M-XXX where XXX is 280 to 340. Canadian Solar - CS6P-XXX-P, CS6P-XXX-M where XXX is 200 to 300; CS6P-XXX-P-SD, CS6K-XXX-P-SD where XXX is 240 to 300; CS6K-XXX-M, CS6K-XXX-MS, CS6K-XXX-M-SD where XXX is 240 to 305; CS6K-XXX-P where XXX is 220 to 300; CS6X-XXX-P where XXX is 250 to 360; CS6V-XXX-M where XXX is 215 to 225; CS6V-XXX-P where XXX is 250 to 255; CS3K-XXX-P where XXX is 250 to 310; CS3K-XXX-MS where XXX is 280 to 330; CS1K-XXX-MS where XXX is 285 to 345, CS1H-XXX-MS, CS1H-XXX-MS-AB where XXX is 310 to 350.ET Solar - ET-P660XXXBB where XXX is 200 to 265; ET-P660XXXWB where XXX is 200 to 265; ET-P660XXXWW where XXX is 200 to 265; ET-P660XXXWWG where XXX is 235 to 265; P660XXXWB/WW where XXX is 200 to 265 and may be followed by WB or WW; P660XXXWWG where XXX is 240 to 250; M660XXXBB where XXX is 250 to 265; M660XXXWW where XXX is 200 to 270.*Hanwha Q Cells - B.LINE PLUS BFR-G4.1-XXX, B.LINE PRO BFR-G4.1-XXX, Q.BASE GY-XXX, Q.PEAK G4-XXX, Q.PLUS BFR-G3.1-XXX, Q.PLUS BFR-G4-XXX, Q.PLUS BFR-G4.1-XXX, Q.PLUS BFR-G4.1/TAA-XXX, Q.PLUS BRF-GY-XXX, Q.PLUS GY-XXX, Q.PLUS G4-XXX, Q.PRO BFR-G4-XXX, Q.PRO BFR-G4.1-XXX, Q.PRO BFR-G4.3-XXX, Q.PRO BFR-GY-XXX, Q.PRO BLK-GY-XX, Q.PRO G4-XXX, Q.PRO GY-XXX, Q.PRO GY/SC-XXX, where XXX is 245 to 295; Q.PEAK BLK-G3.1-XXX, Q.PEAK BLK-G4.1-XXX, Q.PEAK BLK-G4.1/TAA-XXX, Q.PEAK G3.1-XXX, Q.PEAK G4.1-XXX, Q.PEAK G4.1/MAX-XXX, Q.PEAK G4.1/TAA-XXX where XXX is 270 to 325; Q.PEAK DUO BLK-G5-XXX, Q.PEAK DUO G5-XXX, Q.PLUS DUO-G5-XXX where XXX is 290 to 360; Q.PEAK DUO-G7-XXX, Q.PEAK DUO-G7.2-XXX where XXX is 310 to 350; Q.PEAK DUO-BLK-G7-XXX where XXX is 290 to 350; Q.PEAK DUO-G6-XXX, Q.PEAK DUO-G6+-XXX where XXX is 320 to 360; Q.PEAK DUO-BLK-G6-XXX, Q.PEAK DUO-BLK-G6+-XXX where XXX is 310 to 350; Q.PEAK DUO-G8-XXX, Q.PEAK DUO-BLK-G8-XXX, Q.PEAK DUO-G8+-XXX, Q.PEAK DUO-BLK-G8+-XXX where XXX is 290 to 360; Q.PLUS L-G4-XXX, Q.PLUS L-G4.1-XXX, Q.PLUS L-G4.2-XXX where XXX is 280 to 355; Q.PEAK L-G4.1-XXX, Q.PEAK L-G4.2-XXX where XXX is 330-390; Q.PLUS DUO-L-G5-XXX, Q.PLUS DUO-L-G5.1-XXX, Q.PLUS DUO-L-G5.2-XXX, Q.PLUS DUO-L-G5.3-XXX where XXX is 340 to 425; Q.PEAK DUO-L-G5.2-XXX, Q.PEAK DUO-L-G5.3-XXX where XXX is 360 to 425; Q.PEAK DUO-L-G7-XXX, Q.PEAK DUO-L-G7.1-XXX, Q.PEAK DUO-L-G7.2-XXX, Q.PEAK DUO-L-G7.3-XXX where XXX is 360 to 415; Q.PEAK DUO-L-G6-XXX, Q.PEAK DUO-L-G6.2-XXX, Q.PEAK DUO-L-G6.3-XXX, Q.PEAK DUO-L-G8-XXX, Q.PEAK DUO-L-G8.1-XXX, Q.PEAK DUO-L-G8.2-XXX, Q.PEAK DUO-L-G8.3-XXX where XXX is 360 to 430.Hanwha SolarOne - HSL60P6-PB-X-YYYQ where X is 2 or 4, and YYY is 230 to 270, may be followed by additional suffixes.JA Solar - JAP6-60-XXX/3BB where XXX is 235 to 265; JAM6-60-XXX/SI where XXX is 250 to 270; JAP72S01-XXX/SC where XXX is 315 to 335; JAP6(k)-72-XXX/4BB where XXX is 305 to 325.LG Electronics Inc. - LGXXXS1C-G4 where XXX is 250 to 300; LGXXXN1K-G4 where XXX is 280 to 300; LGXXXN1C-G4 where XXX is 280 to 340; LGXXXN2C-G4, LGXXXN2W-G4, where XXX is 360 to 395; LGXXXN2K-G4, where XXX is 360 to 385; LGXXXS2C-G4, LGXXXS2W-G4, where XXX is 300 to 360; LGXXXN2C-B3, LGXXXN2W-B3, where XXX is 330 to 400; LGXXXS1C-A5 where XXX is 280 to 320; LGXXXN1C-A5 where XXX is 320 to 345; LGXXXN1K-A5 where XXX is 310 to 335.Longi Green Energy Technology Co., Ltd.: LR6-60-XXXM, LR6-60BK-XXXM, LR60-HV-XXXM, where XXX is 270 to 300; LR6-60PB-XXXM, LR6-60PE-XXXM, LR6-60PH-XXXM, where XXX is 280 to 320; LR6-60HPB-XXXM where XXX is 295 to 320; LR6-60HPH-XXXM where XXX is 300 to 320. snapnrack.com58Mission Solar: Models MSEXXXSO5T where XXX is 260 to 290; MSEXXXSO5K where XXX is 270 to 290; MSEXXXSQ5T where XXX is 280 to 300; MSEXXXSQ5K where XXX is 285 to 305; MSEXXXMM4J and MSEXXXMM6J where XXX is 320 to 330; MSEXXXSO6W where XXX is 320 to 340; MSEXXXSO4J and MSEXXXSO6J where XXX is 320 to 350; MSEXXXSQ4S and MSEXXXSQ6S where XXX is 345 to 365; MSEXXXSQ8K where XXX is 290 to 315; MSEXXXSQ8T where XXX is 285 to 310.REC Solar PTE. LTD. - RECXXXPE where the XXX is 214 to 280; RECXXXTP where XXX is 260 to 300; RECXXXTP2 where XXX is 260 to 300; RECXXXTP IQ where XXX is 260 to 300; All may be followed by BLK; RECXXXTP72 where XXX is 330 to 345; RECXXX where XXX is 285 to 325, followed by PE72, PE72BLK, PE72 Q2 or PE72 Q3; RECXXXPE72XV where XXX is 295 to 325, followed by PE72 XV, PE72 XV Q2 or PE72 XV Q3; RECXXXNP, where XXX is 310-330; RECXXXTP2M, where XXX is 300-315.Silfab - SLAXXX-M, where XXX is 280 to 300; SLGXXX-M, where XXX is 335 to 360; SLAXXX-P, where XXX is 250 to 265; SLGXXX-P, where XXX is 300 to 315; SSAXXX-M, where XXX is 280 to 300; SSGXXX-M, where XXX is 335 to 360; SSAXXX-P, where XXX is 250 to 260; SSGXXX-P, where XXX is 300 to 315.Solaria: Solaria PowerXT-XXXR-PD and Solaria PowerXT-XXXR-BD, where XXX is 315 to 385.Solar World - SWXXX-Mono where XXX is 200 to 300; SWXXX-Mono XL where XXX is 320 to 350. All may be followed by Black.Suniva Inc – OPTXXX-60-4-YYY where XXX is 240 to 300 and YYY is 100; OPTXXX-60-4-YYY where XXX is 235 to 300 and YYY is 1B0.Trina Solar Ltd - - TSM-XXXPD05.002, TSM-XXXPD05.082, TSM-XXXPD05.05S, TSM-XXXPD05.08S where XXX is 215 to 275; TSM-XXXDD05A.082(II) where XXX is 260 to 315; all may be followed by Black.Ultra Rail has been tested with the following Module Level Power Electronic (MLPE) devices:Celestica International – Listed, Rapid Shutdown Device models DG-006-F001201x and DG-006-F001401x.Enphase – R/C (QIKH2) (QIMS2), Microinverter Models M250, M215 and C250. Provided with or without Enphase R/C (QIMS2) Model EFM-XXMM frame mount kit and Enphase R/C (QIMS2) Engage Cable Model ETXX-240, ETXX-208 or ETXX-277; NRTL Listed, IQ6-60-2-US, IQ6PLUS-72-2-US, IQ7-60-2-US, IQ7-60-B-US, IQ7PLUS-72-2-US, IQ7PLUS-72-B-US.Ginlong Technologies – NRTL Listed, Rapid Shutdown Device Model Solis-RSD-1G; Solis-MLRSD-R1-1G and Solis-MLRSD-R2-1G.SolarEdge – NRTL Listed, Optimizer Models P300-5NC4ARS, P320-5NC4ARS, P300-5NC4AFS, P320-5NC4AFS, P370-5NC4AFS, or P400-5NC4AFS.Note: Ginlong Solis-MLRSD-R1-1G and Solis-MLRSD-R2-1G have not been investigated for bonding since the enclosures are constructed entirely of polymeric materials.All MLPE models noted above have been evaluated for use with SnapNrack MLPE Rail Attachment Kit and MLPE Frame Attachment Kit except SolarEdge Models P300-5NC4ARS and P320-5NCARS.The following MLPE devices have been evaluated for use with the SnapNrack MLPE Rail Attachment Kit only:SMA – Rapid Shutdown Device Model RSB-2S-US-10Only bonding to the backplates of these devices was evaluated. Functionality of the devices was not considered.The SolarEdge Microinverter Frame Mounted Bracket of Models P300-5NC4AFS and P320-5NC4AFS has been evaluated for all modules within flange thickness range of 1.5 mm to 2.3 mm. When adding modules for bonding, consideration must be given to the SolarEdge Microinverter Frame Mounted Models P300-5NC4AFS and P320-5NC4AFS. This product clamps onto the module flange using an integral bracket.Suniva modules were not evaluated for bonding to the Mounting Bracket.Additional MLPE devices were evaluated for attachment to the module frames through the device mounting means. These devices have not been evaluated for bonding:Tigo – Monitoring Device models TS4-R-F, TS4-R-M, TS4-R-O, TS4-R-S, TS4-R-M-DUO, TS4-R-O-DUO, TS4-R-S-DUO