HomeMy WebLinkAboutPLANS REVISED REDLINED APPROVED - 21-00099 - Realty Quest - RemodelDescription : Realty Quest - RemodelAddress : 117 W Main StRecord Type : Commercial - RemodelDocument Filename : 117 W MAIN ST REXBURG-Reviewed-Corrections-Required.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00099 Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Author Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Realty Quest - 117 W Main St Suite 101 & 102 - RemodelAddress : 117 W Main St Suite 101 & 102Application Type : Document Filename : 117 W MAIN ST REXBURG.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments G-101 Free text Cody Jones : Building Open 1 Ground snow load of 50 psf A-101 Free text Cody Jones : Building Open 3 Exit signs and lighting to comply with sections 1008 and 1013 A-101 Free text Cody Jones : Building Open 3 Any new wood framing in direct contact with concrete willneed to be pressure treated. A-101 Free text Cody Jones : Building Open 3 Exhaust fans to be installed in bathrooms. A-101 Free text Cody Jones : Building Open 3 Seating at tables, counters and work areas to comply with IBC1109.11 ADA-101 Free text Cody Jones : Building Open 4 Per 2406.4.2 Glazing adjacent to a door where the nearestvertical edge of the glazing is within 24" arc needs to betempered. ADA-101 Free text Cody Jones : Building Open 4 If the turning space is to include knee and toe clearance it is tocomply with section 306 of the ICC A11.7.1 # 21-00099Commercial - Remodel Report Date: 02-23-21 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) INDEX OF SHEETS G-101 C-101 A-101 ADA-101 COVER SHEET SITE MAIN FLOOR ADA APPROACH AND RADIUS LOCATION: REXBURG, ID SNOW LOAD: 35 PSF WIND SPEED: 115 MPH FROST DEPTH: 36" SEISMIC: D-1 REGULATION: 2018 IBC 117 W MAIN ST REXBURG DR A W N BY : CH K 'D BY : BW BW PL O T DA T E : 2 /11 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E CO V E R SH E E T SH E E T TI T L E : G-101 PLN# 21-01-05 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . Ground snow load of 50 psf MAIN ST S 1 ST W 417 W MAIN 1 2 3 4 5 6 7 APX STALL SIZE AS MEASURE FROM GIS 10X22 1 SITE PLAN SCALE: 1" = 20' PROJECT LOCATION 117 W MAIN ST PROIXIMITY MAP SITE PLAN NOTE: 1. SOUTH FORK DESIGN GROUP DOES NOT PROVIDE SURVEYING, CIVIL ENGINEERING OR GEO TECHNICAL ENGINEERING. IT IS THE RESPONSIBILITY OF THE OWNER/CONTRACTOR TO ACQUIRE THESE SERVICES IF APPLICABLE. 2. U.N.O. THE SITE PLAN IS BASED ON MEASUREMENTS OBTAINED FROM PUBLIC RECORD DOCUMENTS OR GIS SYSTEM INFORMATION AND MAY NOT BE EXACT. 3. IT IS THE OWNERS/CONTRACTORS RESPONSIBILITY TO OBTAIN NECESSARY SURVEY DATA, INCLUDING TOPOGRAPHICAL INFORMATION 4. LOCATION OF UTILITIES SHOULD BE CONFIRMED BY THE CONTRACTOR PRIOR TO EXCAVATION 5. WHERE SEPTIC AND/OR FRESH WATER WELLS ARE NECESSARY, PERMITS AND LOCATION SHOULD BE OBTAINED FROM THE AUTHORITY HAVING JURISDICTION (TYPICALLY HEALTH DEPT) 6. INDICATED LOCATIONS OF SEPTIC, WELL, AND/OR UTILITIES ARE ASSUMED OR SUGGESTED AND SHOULD BE VERIFIED AND APPROVED BY THE OWNER/CONTRACTOR AND THE AUTHORITY HAVING JURISDICTION DR A W N BY : CH K 'D BY : BW BW PL O T DA T E : 2 /11 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E SI T E SH E E T TI T L E : C-101 PLN# 21-01-05 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 1,251 sq ft W W /DR OFFICEA RECEPTION AREA 18'-3" x 17'-2" OFFICE 1 15'-0" x 12'-2" OFFICE 2 15'-0" x 12'-3" STORAGE ROOM 11'-4" x 9'-4" BREAK ROOM 8'-6" x 9'-6" PATIENT ROOM 1 18'-3" x 17'-2"RECEPTION AREA 10'-9" x 17'-10" PATIENT ROOM 2 13'-1" x 11'-5" PATIENT ROOM 3 13'-1" x 12'-4" TAN ROOM 7'-6" x 5'-6" PREP ROOM 7'-7" x 9'-6" WAITING AREA 10'-8" x 16'-7" ENTRY AREA 7'-3" x 5'-5" 1 2 1 2 A A A A 2 2 2 2 3 980 sq ft OFFICEB DOOR SCHEDULE ID 1 2 3 QTY 2 6 1 LOCATION Interior Interior Interior FIRE RATING DOOR W 2'-10" 3' 3' HT 6'-8" 6'-8" 6'-8" NOTES COMMERCIAL WINDOW SCHEDULE ID A TYPE FIXED QTY 4 HEIGHT 6'-8" SIZE W 3'-8" HT 6'-2" NOTES SAFETY GLASS 1 MAIN LEVEL PLAN SCALE: 1/4" = 1'-0" NOTE: ONLY NEW DOORS AND WINDOWS ARE REPRESENTED ON THESE SCHEDULES DR A W N BY : CH K 'D BY : BW BW PL O T DA T E : 2 /11 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E MA I N FL O O R SH E E T TI T L E : A-101 PLN# 21-01-05 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . Exit signs and lighting to comply with sections 1008 and 1013 Any new wood framing in direct contact with concrete will need to be pressure treated. Exhaust fans to be installed in bathrooms. Seating at tables, counters and work areas to comply with IBC 1109.11 W W /DR RECEPTION AREA 18'-3" x 17'-2" OFFICE 1 15'-0" x 12'-2" OFFICE 2 15'-0" x 12'-3" STORAGE ROOM 11'-4" x 9'-4" BREAK ROOM 8'-6" x 9'-6" PATIENT ROOM 1 18'-3" x 17'-2"RECEPTION AREA 10'-9" x 17'-10" PATIENT ROOM 2 13'-1" x 11'-5" PATIENT ROOM 3 13'-1" x 12'-4" TAN ROOM 7'-6" x 5'-6" PREP ROOM 7'-7" x 9'-6" WAITING AREA 10'-8" x 16'-7" ENTRY AREA 7'-3" x 5'-5" 1 ADA APPROACH AND RADIUS SCALE: 1/4" = 1'-0" DR A W N BY : CH K 'D BY : BW BW PL O T DA T E : 2 /11 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E AD A AP P R O A C H AN D RA D I U S SH E E T TI T L E : ADA-101 PLN# 21-01-05 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . Per 2406.4.2 Glazing adjacent to a door where the nearest vertical edge of the glazing is within 24" arc needs to be tempered. If the turning space is to include knee and toe clearance it is to comply with section 306 of the ICC A11.7.1 4.72 ft 0 . 7 2 i n 4.28 ft 10. 2 4 f t