HomeMy WebLinkAboutPLANS REVISED - 21-00099 - Realty Quest - RemodelINDEX OF SHEETS
G-101
C-101
A-101
ADA-101
COVER SHEET
SITE
MAIN FLOOR
ADA APPROACH AND RADIUS
LOCATION: REXBURG, ID
SNOW LOAD: 50 PSF
WIND SPEED: 115 MPH
FROST DEPTH: 36"
SEISMIC: D-1
REGULATION: IRC 2015
117 W MAIN ST REXBURG
DR
A
W
N
BY
:
CH
K
'D
BY
:
BW
#1 -5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
2 /24
/20
2
1
EN
G
I
N
E
E
R
:
RA
Y
MC
D
O
U
G
A
L
,
PE
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
CO
V
E
R
SH
E
E
T
SH
E
E
T
TI
T
L
E
:
G-101
PLN# 21-01-05
2 /24
/20
2
1
AD
D
E
D
NO
T
E
S
AF
T
E
R
CI
T
Y
RE
V
I
E
W
10
6
6
No
r
t
h
Ye
l
l
o
w
s
t
o
n
e
Hw
y
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.so
u
t
h
f
o
r
k
e
n
g
i
n
e
e
r
i
n
g
.co
m
20
8
-85
2
-62
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
TO
D
D
DA
V
I
S
11
7
W
MA
I
N
ST
RE
X
B
U
R
G
,
ID
A
H
O
83
4
4
0
Co
p
y
r
i
g
h
t
20
2
1
|
So
u
t
h
f
o
r
k
En
g
i
n
e
e
r
i
n
g
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
MAIN ST
S
1 ST
W
417 W
MAIN
1
2
3
4
5
6
7
APX STALL SIZE
AS MEASURE
FROM GIS 10X22
1 SITE PLAN
SCALE: 1" = 20'
PROJECT LOCATION
117 W MAIN ST
PROIXIMITY MAP
SITE PLAN NOTE:
1. SOUTH FORK DESIGN GROUP DOES NOT PROVIDE SURVEYING, CIVIL
ENGINEERING OR GEO TECHNICAL ENGINEERING. IT IS THE RESPONSIBILITY OF THE
OWNER/CONTRACTOR TO ACQUIRE THESE SERVICES IF APPLICABLE.
2. U.N.O. THE SITE PLAN IS BASED ON MEASUREMENTS OBTAINED FROM PUBLIC
RECORD DOCUMENTS OR GIS SYSTEM INFORMATION AND MAY NOT BE EXACT.
3. IT IS THE OWNERS/CONTRACTORS RESPONSIBILITY TO OBTAIN NECESSARY
SURVEY DATA, INCLUDING TOPOGRAPHICAL INFORMATION
4. LOCATION OF UTILITIES SHOULD BE CONFIRMED BY THE CONTRACTOR PRIOR TO
EXCAVATION
5. WHERE SEPTIC AND/OR FRESH WATER WELLS ARE NECESSARY, PERMITS AND
LOCATION SHOULD BE OBTAINED FROM THE AUTHORITY HAVING JURISDICTION
(TYPICALLY HEALTH DEPT)
6. INDICATED LOCATIONS OF SEPTIC, WELL, AND/OR UTILITIES ARE ASSUMED OR
SUGGESTED AND SHOULD BE VERIFIED AND APPROVED BY THE OWNER/CONTRACTOR
AND THE AUTHORITY HAVING JURISDICTION
DR
A
W
N
BY
:
CH
K
'D
BY
:
BW
#1 -5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
2 /24
/20
2
1
EN
G
I
N
E
E
R
:
RA
Y
MC
D
O
U
G
A
L
,
PE
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
SI
T
E
SH
E
E
T
TI
T
L
E
:
C-101
PLN# 21-01-05
2 /24
/20
2
1
AD
D
E
D
NO
T
E
S
AF
T
E
R
CI
T
Y
RE
V
I
E
W
10
6
6
No
r
t
h
Ye
l
l
o
w
s
t
o
n
e
Hw
y
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.so
u
t
h
f
o
r
k
e
n
g
i
n
e
e
r
i
n
g
.co
m
20
8
-85
2
-62
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
TO
D
D
DA
V
I
S
11
7
W
MA
I
N
ST
RE
X
B
U
R
G
,
ID
A
H
O
83
4
4
0
Co
p
y
r
i
g
h
t
20
2
1
|
So
u
t
h
f
o
r
k
En
g
i
n
e
e
r
i
n
g
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
1,251 sq ft
W W /DR
OFFICEA
NOTE:
-SEATING AT TABLES, COUNTERS, AND WORK AREAS TO COMPLY WITH IBC 1109.11
-ANY NEW FRAMING IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED WOOD
-EXIT SIGNS TO COMPLY WITH SECTIONS 1008 AND 1013 OF THE IBC
-BATHROOM EXHAUST FAN REQUIRED TO VENT AIR TO THE EXTERIOR OF BUILDING
-PATIENT CARE AREAS TO BE WIRED IN ACCORDANCE WITH ARTICLE 517 OF THE 2017 NEC
RECEPTION AREA
18'-3" x 17'-2"
OFFICE 1
15'-0" x 12'-2"
OFFICE 2
15'-0" x 12'-3"
STORAGE ROOM
11'-4" x 9'-4"
BREAK ROOM
8'-6" x 9'-6"
PATIENT ROOM 1
18'-3" x 17'-2"RECEPTION AREA
10'-9" x 17'-10"
PATIENT ROOM 2
13'-1" x 11'-5"
PATIENT ROOM 3
13'-1" x 12'-4"
TAN ROOM
7'-6" x 5'-6"
PREP ROOM
7'-7" x 9'-6"
WAITING AREA
10'-8" x 16'-7"
ENTRY AREA
7'-3" x 5'-5"
2
3
2
3
3
3
3
980 sq ft
OFFICEB
4'-45/8"4'-101/4"
DOOR SCHEDULE
ID
2
2
3
3
3
3
3
QTY
1
1
1
1
1
1
1
LOCATION
Interior
Interior
Interior
Interior
Interior
Interior
Interior
FIRE RATING DOOR
W
2'-10"
2'-10"
3'
3'
3'
3'
3'
HT
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
NOTES
1 MAIN LEVEL PLAN
SCALE: 1/4" = 1'-0"
DR
A
W
N
BY
:
CH
K
'D
BY
:
BW
#1 -5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
2 /24
/20
2
1
EN
G
I
N
E
E
R
:
RA
Y
MC
D
O
U
G
A
L
,
PE
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
MA
I
N
FL
O
O
R
SH
E
E
T
TI
T
L
E
:
A-101
PLN# 21-01-05
2 /24
/20
2
1
AD
D
E
D
NO
T
E
S
AF
T
E
R
CI
T
Y
RE
V
I
E
W
10
6
6
No
r
t
h
Ye
l
l
o
w
s
t
o
n
e
Hw
y
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.so
u
t
h
f
o
r
k
e
n
g
i
n
e
e
r
i
n
g
.co
m
20
8
-85
2
-62
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
TO
D
D
DA
V
I
S
11
7
W
MA
I
N
ST
RE
X
B
U
R
G
,
ID
A
H
O
83
4
4
0
Co
p
y
r
i
g
h
t
20
2
1
|
So
u
t
h
f
o
r
k
En
g
i
n
e
e
r
i
n
g
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
W W /DR
NOTE:
-ALL TURNING RADIUS REQUIRE KNEE AND TOE CLEARANCE PER ICC A11.7.1 SECTION 306
-PANNEL GLAZING REQUIRED PER 2406.2 WHERE NEAREST EDGE OF GLAZING IS LOCATED WITHIN 24"
OF DOOR SWING ARC
RECEPTION AREA
18'-3" x 17'-2"
OFFICE 1
15'-0" x 12'-2"
OFFICE 2
15'-0" x 12'-3"
STORAGE ROOM
11'-4" x 9'-4"
BREAK ROOM
8'-6" x 9'-6"
PATIENT ROOM 1
18'-3" x 17'-2"RECEPTION AREA
10'-9" x 17'-10"
PATIENT ROOM 2
13'-1" x 11'-5"
PATIENT ROOM 3
13'-1" x 12'-4"
TAN ROOM
7'-6" x 5'-6"
PREP ROOM
7'-7" x 9'-6"
WAITING AREA
10'-8" x 16'-7"
ENTRY AREA
7'-3" x 5'-5"
1 ADA APPROACH AND RADIUS
SCALE: 1/4" = 1'-0"
DR
A
W
N
BY
:
CH
K
'D
BY
:
BW
#1 -5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
2 /24
/20
2
1
EN
G
I
N
E
E
R
:
RA
Y
MC
D
O
U
G
A
L
,
PE
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
AD
A
AP
P
R
O
A
C
H
AN
D
RA
D
I
U
S
SH
E
E
T
TI
T
L
E
:
ADA-101
PLN# 21-01-05
2 /24
/20
2
1
AD
D
E
D
NO
T
E
S
AF
T
E
R
CI
T
Y
RE
V
I
E
W
10
6
6
No
r
t
h
Ye
l
l
o
w
s
t
o
n
e
Hw
y
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.so
u
t
h
f
o
r
k
e
n
g
i
n
e
e
r
i
n
g
.co
m
20
8
-85
2
-62
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
TO
D
D
DA
V
I
S
11
7
W
MA
I
N
ST
RE
X
B
U
R
G
,
ID
A
H
O
83
4
4
0
Co
p
y
r
i
g
h
t
20
2
1
|
So
u
t
h
f
o
r
k
En
g
i
n
e
e
r
i
n
g
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.