Loading...
HomeMy WebLinkAboutPLANS REVISED - 21-00099 - Realty Quest - RemodelINDEX OF SHEETS G-101 C-101 A-101 ADA-101 COVER SHEET SITE MAIN FLOOR ADA APPROACH AND RADIUS LOCATION: REXBURG, ID SNOW LOAD: 50 PSF WIND SPEED: 115 MPH FROST DEPTH: 36" SEISMIC: D-1 REGULATION: IRC 2015 117 W MAIN ST REXBURG DR A W N BY : CH K 'D BY : BW #1 -5 Ch e c k e d By PL O T DA T E : 2 /24 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E CO V E R SH E E T SH E E T TI T L E : G-101 PLN# 21-01-05 2 /24 /20 2 1 AD D E D NO T E S AF T E R CI T Y RE V I E W 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . MAIN ST S 1 ST W 417 W MAIN 1 2 3 4 5 6 7 APX STALL SIZE AS MEASURE FROM GIS 10X22 1 SITE PLAN SCALE: 1" = 20' PROJECT LOCATION 117 W MAIN ST PROIXIMITY MAP SITE PLAN NOTE: 1. SOUTH FORK DESIGN GROUP DOES NOT PROVIDE SURVEYING, CIVIL ENGINEERING OR GEO TECHNICAL ENGINEERING. IT IS THE RESPONSIBILITY OF THE OWNER/CONTRACTOR TO ACQUIRE THESE SERVICES IF APPLICABLE. 2. U.N.O. THE SITE PLAN IS BASED ON MEASUREMENTS OBTAINED FROM PUBLIC RECORD DOCUMENTS OR GIS SYSTEM INFORMATION AND MAY NOT BE EXACT. 3. IT IS THE OWNERS/CONTRACTORS RESPONSIBILITY TO OBTAIN NECESSARY SURVEY DATA, INCLUDING TOPOGRAPHICAL INFORMATION 4. LOCATION OF UTILITIES SHOULD BE CONFIRMED BY THE CONTRACTOR PRIOR TO EXCAVATION 5. WHERE SEPTIC AND/OR FRESH WATER WELLS ARE NECESSARY, PERMITS AND LOCATION SHOULD BE OBTAINED FROM THE AUTHORITY HAVING JURISDICTION (TYPICALLY HEALTH DEPT) 6. INDICATED LOCATIONS OF SEPTIC, WELL, AND/OR UTILITIES ARE ASSUMED OR SUGGESTED AND SHOULD BE VERIFIED AND APPROVED BY THE OWNER/CONTRACTOR AND THE AUTHORITY HAVING JURISDICTION DR A W N BY : CH K 'D BY : BW #1 -5 Ch e c k e d By PL O T DA T E : 2 /24 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E SI T E SH E E T TI T L E : C-101 PLN# 21-01-05 2 /24 /20 2 1 AD D E D NO T E S AF T E R CI T Y RE V I E W 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . 1,251 sq ft W W /DR OFFICEA NOTE: -SEATING AT TABLES, COUNTERS, AND WORK AREAS TO COMPLY WITH IBC 1109.11 -ANY NEW FRAMING IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED WOOD -EXIT SIGNS TO COMPLY WITH SECTIONS 1008 AND 1013 OF THE IBC -BATHROOM EXHAUST FAN REQUIRED TO VENT AIR TO THE EXTERIOR OF BUILDING -PATIENT CARE AREAS TO BE WIRED IN ACCORDANCE WITH ARTICLE 517 OF THE 2017 NEC RECEPTION AREA 18'-3" x 17'-2" OFFICE 1 15'-0" x 12'-2" OFFICE 2 15'-0" x 12'-3" STORAGE ROOM 11'-4" x 9'-4" BREAK ROOM 8'-6" x 9'-6" PATIENT ROOM 1 18'-3" x 17'-2"RECEPTION AREA 10'-9" x 17'-10" PATIENT ROOM 2 13'-1" x 11'-5" PATIENT ROOM 3 13'-1" x 12'-4" TAN ROOM 7'-6" x 5'-6" PREP ROOM 7'-7" x 9'-6" WAITING AREA 10'-8" x 16'-7" ENTRY AREA 7'-3" x 5'-5" 2 3 2 3 3 3 3 980 sq ft OFFICEB 4'-45/8"4'-101/4" DOOR SCHEDULE ID 2 2 3 3 3 3 3 QTY 1 1 1 1 1 1 1 LOCATION Interior Interior Interior Interior Interior Interior Interior FIRE RATING DOOR W 2'-10" 2'-10" 3' 3' 3' 3' 3' HT 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" NOTES 1 MAIN LEVEL PLAN SCALE: 1/4" = 1'-0" DR A W N BY : CH K 'D BY : BW #1 -5 Ch e c k e d By PL O T DA T E : 2 /24 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E MA I N FL O O R SH E E T TI T L E : A-101 PLN# 21-01-05 2 /24 /20 2 1 AD D E D NO T E S AF T E R CI T Y RE V I E W 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d . W W /DR NOTE: -ALL TURNING RADIUS REQUIRE KNEE AND TOE CLEARANCE PER ICC A11.7.1 SECTION 306 -PANNEL GLAZING REQUIRED PER 2406.2 WHERE NEAREST EDGE OF GLAZING IS LOCATED WITHIN 24" OF DOOR SWING ARC RECEPTION AREA 18'-3" x 17'-2" OFFICE 1 15'-0" x 12'-2" OFFICE 2 15'-0" x 12'-3" STORAGE ROOM 11'-4" x 9'-4" BREAK ROOM 8'-6" x 9'-6" PATIENT ROOM 1 18'-3" x 17'-2"RECEPTION AREA 10'-9" x 17'-10" PATIENT ROOM 2 13'-1" x 11'-5" PATIENT ROOM 3 13'-1" x 12'-4" TAN ROOM 7'-6" x 5'-6" PREP ROOM 7'-7" x 9'-6" WAITING AREA 10'-8" x 16'-7" ENTRY AREA 7'-3" x 5'-5" 1 ADA APPROACH AND RADIUS SCALE: 1/4" = 1'-0" DR A W N BY : CH K 'D BY : BW #1 -5 Ch e c k e d By PL O T DA T E : 2 /24 /20 2 1 EN G I N E E R : RA Y MC D O U G A L , PE DE S C R I P T I O N RE V I S I O N DA T E AD A AP P R O A C H AN D RA D I U S SH E E T TI T L E : ADA-101 PLN# 21-01-05 2 /24 /20 2 1 AD D E D NO T E S AF T E R CI T Y RE V I E W 10 6 6 No r t h Ye l l o w s t o n e Hw y Re x b u r g , ID 83 4 4 0 ww w .so u t h f o r k e n g i n e e r i n g .co m 20 8 -85 2 -62 3 6 So u t h Fo r k De s i g n Gr o u p , LL C TO D D DA V I S 11 7 W MA I N ST RE X B U R G , ID A H O 83 4 4 0 Co p y r i g h t 20 2 1 | So u t h f o r k En g i n e e r i n g | Al l Ri g h t s Re s e r v e d .