Loading...
HomeMy WebLinkAboutPLANS REDLINED - 21-00013 - 1362 Clover Court - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 1362 Clover Court - New SFRAddress : Record Type : New Single Family ResidenceDocument Filename : 29402-fitzgerald-set-2x6-ns.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00013 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments Pg 2 Free text Larry Beesley : Building Open 2 Minimum Frost Depth Ground Surface to Bottom of Footing36" Pg 2 Free text Larry Beesley : Building Open 2 Roof Ventilation as per R806 Pg 2 Free text Larry Beesley : Building Open 2 Street NumberDisplayed on House Pg 3 Free text Larry Beesley : Building Open 3 3' landing is required Pg 3 Free text Larry Beesley : Building Open 3 Roof Ventilation as per R806 Pg 3 Free text Larry Beesley : Building Open 3 Ground Surface to Slope away from Foundation a minimum of6" within first 10 ft. Pg 3 Free text Larry Beesley : Building Open 3 Ladder required in window well if 44" deep or deeper Pg 4 Free text Larry Beesley : Building Open 4 Follow the engineers specks for the foundation and the Holddowns Pg 4 Free text Larry Beesley : Building Open 4 SD CO Pg 4 Free text Larry Beesley : Building Open 4 Check and follow the engineers plan and specks for holddowns and building specks Pg 4 Free text Larry Beesley : Building Open 4 check the basement floor plan for window and room layouts New Single Family Residence This house plan has been reviewed for code compliance and will be inspected following the 2018 IRC code. You must follow the engineers speck and red lines plans. Approval of plans does not constitute approval of variance from code Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments Pg 4 Free text Larry Beesley : Building Open 4 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" Pg 5 Free text Larry Beesley : Building Open 5 F Pg 5 Free text Larry Beesley : Building Open 5 F Pg 5 Free text Larry Beesley : Building Open 5 SD Pg 5 Free text Larry Beesley : Building Open 5 SD Pg 5 Free text Larry Beesley : Building Open 5 SD CO Pg 5 Free text Larry Beesley : Building Open 5 A 3' landing is required if there is more than 2 risers on thesteps from the floor to the patio. Pg 5 Free text Larry Beesley : Building Open 5 Attic Access 22"x30" minimum access where attic clear heightexceeds 30" (R807) Pg 5 Free text Larry Beesley : Building Open 5 Door from Garage to House (1 3/8" solid wood or steel door,or 20 min. fire-rated door) R309.1 Pg 5 Free text Larry Beesley : Building Open 5 Flue chase shown on plans (B-vents not to be inside insulatedwalls without insulation shield) Pg 6 Free text Larry Beesley : Building Open 6 2 rows of Ice and water shield required. Pg 6 Free text Larry Beesley : Building Open 6 Roof Trusses (designed according to R802.10.1) 35 # Snow and90 mph winds (Local Conditions) Pg 6 Free text Larry Beesley : Building Open 6 The Ice and water shield must extend 2' inside the exteriorwall line. Pg 7 Free text Larry Beesley : Building Open 7 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Minimum Frost Depth Ground Surface to Bottom of Footing 36" Roof Ventilation as per R806 Street Number Displayed on House 3' landing is required Roof Ventilation as per R806 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Ladder required in window well if 44" deep or deeper Follow the engineers specks for the foundation and the Hold downs SD CO Check and follow the engineers plan and specks for hold downs and building specks check the basement floor plan for window and room layouts Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" F F SD SD SD CO A 3' landing is required if there is more than 2 risers on the steps from the floor to the patio. Attic Access 22"x30" minimum access where attic clear height exceeds 30" (R807) Door from Garage to House (1 3/8" solid wood or steel door, or 20 min. fire-rated door) R309.1 Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield) 2 rows of Ice and water shield required. Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) The Ice and water shield must extend 2' inside the exterior wall line. Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"