Loading...
HomeMy WebLinkAboutPLANS NORTH CLUBHOUSE REDLINED - 20-00949 - The Gates Apartments - Solar PanelsAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : The Gates Apartments - Solar PanelsAddress : 370 W 7th SRecord Type : Solar PanelsDocument Filename : The Gates Apartments North Clubhouse 1st SS.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 20-00949 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments PV01 Free text Larry Beesley : Building Open 1 Solar panels and rails are designed for snow loads of 35pounds per square foot. PV02-SITE Free text Larry Beesley : Building Open 2 Solar panels and rails are designed for snow loads of 35pounds per square foot. Solar Panels Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) STREET VIEWAERIAL VIEW MODULE: (28) TRINA TSM-DD06H.05(II) 325 325W PV Module INVERTER: (1) SOLAREDGE SE7600H-US String Inverter 240VAC RACKING: UNIRAC Roof Mounted PV System OPTIMIZER: (28) SOLAREDGE P340 DC Optimizers WIND SPEED: 115 MPH EXPOSURE CATEGORY: CA. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES. B. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. C. PRIOR TO COMMENCMENT OF WORK CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY DBM OF ANY INCONSISTENCIES. D. ALL EQUIPMENT SHALL BE INSTALLED AS SHOWN. F. WIRING SHALL NOT BE INSTALLED WITHIN 10 INCHES OF ROOF DECKING EXCEPT WHERE DIRECTLY BELOW PV EQUIPMENT SYSTEM SUMMARY DESIGN CRITERIA SCOPE OF WORK GENERAL NOTES OCCUPANCY & CONSTRUCTION TYPE OCCUPANCY - A3 CONSTRUCTION - V-B SHEET INDEX PAGE NUMBER PAGE TITLE PV01 TITLE PAGE PV02 SITE PLAN PV03 ONE LINE & ELECTRICAL PV04 ARRAY & STRINGING DETAIL PV05 LABEL PLAN SPECS SPECSHEETS AND DOCUMENTS 2017 NATIONAL ELECTRICAL CODE (NEC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) DC System Size: 9.1 kW Asphalt/Comp shingle roof pitch: 6/12 Anchored on 48 inch centers using UL listed racking system UV resistant cable ties (not zip ties) used for permanent wire management in accordance with (NEC 110.2,1110.3(A-B), 300.4) Junction boxes mounted flush w/racking APPLICABLE CODES E. WARNINGS PER NEC 690. Set Reviewed By: PV-041115-011207 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT PORTICADE CONSTRUCTION NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SI T E I N F O R M A T I O N : Th e G a t e s A p a r t m e n t s N o r t h C l u b h o u s e 37 0 W 7 t h S , Re x b u r g , I D 8 3 4 4 0 SY S T E M I N F O R M A T I O N : 9. 1 k W DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # 2020-PORT DATE: 11/24/2020 DESIGNED BY: J. Fairchild SHEET NAME: PAGE #REVISION: 1PV01 COVER PAGE 12/07/2020 VSE Project Number: U2783-0046-201 Firm License Number: C2269 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Mechanical, architectural, and all other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. Solar panels and rails are designed for snow loads of 35 pounds per square foot. PHOTOVOLTAIC MODULES **PV Modules cannot be installed over vents 3' 18" 39.53" 66.85" FIRE CODE SETBACKS ARRAY DETAIL A B C D AZIMUTH 270°90° TILT ANGLE 27°27° MODULE COUNT 14 14 90 120 150180210 240 270 300 330 0 30 60 W E S N 80 70 50 4O 2010350 320310 290 280 260 250 230220 200190 170160 140 130 110 100 340 AZIMUTH 180 SITE INDEX**AC DISCONNECT LOCATED 10' OR LESS FROM UTILITY METER 110' 300' 190' 180' VISIBLE, LOCKABLE, LABELED AC DISCONNECT UTILITY METER & MSP INVERTER & DC DISCONNECT 37'-4" 52'-9" 37'-4" 52'-9" JUNCTION BOX CONDUIT RUN PV MODULES CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT PORTICADE CONSTRUCTION NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC SI T E I N F O R M A T I O N : Th e G a t e s A p a r t m e n t s N o r t h C l u b h o u s e 37 0 W 7 t h S , Re x b u r g , I D 8 3 4 4 0 SY S T E M I N F O R M A T I O N : 9. 1 k W DBM SOLAR DESIGN AND CONSULTING COMPANY, LLC P: (801) 690-4873 E: SUPPORT@DBMSOLAR.COM WWW.DBMSOLAR.COM PROJECT # 2020-PORT DATE: 11/24/2020 DESIGNED BY: J. Fairchild SHEET NAME: PAGE #REVISION: 1PV02 PROPERTY DETAIL 12/07/2020 VSE Project Number: U2783-0046-201 Firm License Number: C2269 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Mechanical, architectural, and all other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. Solar panels and rails are designed for snow loads of 35 pounds per square foot.