HomeMy WebLinkAboutPLANS NORTH CLUBHOUSE REDLINED - 20-00949 - The Gates Apartments - Solar PanelsAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Description : The Gates Apartments - Solar PanelsAddress : 370 W 7th SRecord Type : Solar PanelsDocument Filename : The Gates Apartments North Clubhouse 1st SS.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report Approved
# 20-00949
Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments
PV01 Free text Larry Beesley : Building Open 1 Solar panels and rails are designed for snow loads of 35pounds per square foot.
PV02-SITE Free text Larry Beesley : Building Open 2 Solar panels and rails are designed for snow loads of 35pounds per square foot.
Solar Panels
Approval of plans does not constitute approval of variance from code
Powered by TCPDF (www.tcpdf.org)
STREET VIEWAERIAL VIEW
MODULE: (28) TRINA TSM-DD06H.05(II) 325 325W PV Module
INVERTER: (1) SOLAREDGE SE7600H-US String Inverter 240VAC
RACKING: UNIRAC Roof Mounted PV System
OPTIMIZER: (28) SOLAREDGE P340 DC Optimizers
WIND SPEED: 115 MPH
EXPOSURE CATEGORY: CA. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES.
B. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING
REQUIREMENTS.
C. PRIOR TO COMMENCMENT OF WORK CONTRACTOR SHALL VERIFY EXISTING
CONDITIONS AND NOTIFY DBM OF ANY INCONSISTENCIES.
D. ALL EQUIPMENT SHALL BE INSTALLED AS SHOWN.
F. WIRING SHALL NOT BE INSTALLED WITHIN 10 INCHES OF ROOF DECKING
EXCEPT WHERE DIRECTLY BELOW PV EQUIPMENT
SYSTEM SUMMARY
DESIGN CRITERIA
SCOPE OF WORK
GENERAL NOTES
OCCUPANCY & CONSTRUCTION TYPE
OCCUPANCY - A3
CONSTRUCTION - V-B
SHEET INDEX
PAGE NUMBER PAGE TITLE
PV01 TITLE PAGE
PV02 SITE PLAN
PV03 ONE LINE & ELECTRICAL
PV04 ARRAY & STRINGING DETAIL
PV05 LABEL PLAN
SPECS SPECSHEETS AND DOCUMENTS
2017 NATIONAL ELECTRICAL CODE (NEC)
2015 INTERNATIONAL FIRE CODE (IFC)
2015 INTERNATIONAL BUILDING CODE (IBC)
2015 INTERNATIONAL RESIDENTIAL CODE (IRC)
DC System Size: 9.1 kW
Asphalt/Comp shingle roof pitch: 6/12
Anchored on 48 inch centers using UL listed racking system
UV resistant cable ties (not zip ties) used for permanent wire management in
accordance with (NEC 110.2,1110.3(A-B), 300.4)
Junction boxes mounted flush w/racking
APPLICABLE CODES
E. WARNINGS PER NEC 690.
Set Reviewed By:
PV-041115-011207
CONFIDENTIAL - THE INFORMATION
HEREIN CONTAINED SHALL NOT BE
USED FOR THE BENEFIT OF ANYONE
EXCEPT PORTICADE CONSTRUCTION
NOR SHALL IT BE DISCLOSED IN
WHOLE OR IN PART TO OTHERS
OUTSIDE RECIPIENTS
ORGANIZATION, EXCEPT IN
CONNECTION WITH THE SALE AND
USE OF THE RESPECTIVE
EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF DBM SOLAR DESIGN
AND CONSULTING COMPANY, LLC
SI
T
E
I
N
F
O
R
M
A
T
I
O
N
:
Th
e
G
a
t
e
s
A
p
a
r
t
m
e
n
t
s
N
o
r
t
h
C
l
u
b
h
o
u
s
e
37
0
W
7
t
h
S
,
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
SY
S
T
E
M
I
N
F
O
R
M
A
T
I
O
N
:
9.
1
k
W
DBM SOLAR DESIGN AND
CONSULTING COMPANY, LLC
P: (801) 690-4873
E: SUPPORT@DBMSOLAR.COM
WWW.DBMSOLAR.COM
PROJECT #
2020-PORT
DATE:
11/24/2020
DESIGNED BY:
J. Fairchild
SHEET NAME:
PAGE #REVISION:
1PV01
COVER PAGE
12/07/2020
VSE Project Number: U2783-0046-201
Firm License Number: C2269
Vector Structural Engineering has reviewed the existing structure
with loading from the solar array and lag screw connections to the
existing framing. The design of the racking system, connections,
and all other structure is by others. Mechanical, architectural, and
all other nonstructural aspects of the design are by others.
Electrical is by others, unless stamped by Dean Levorsen.
Solar panels and rails are designed for snow loads of 35 pounds per square foot.
PHOTOVOLTAIC MODULES **PV Modules cannot be installed over vents
3'
18"
39.53"
66.85"
FIRE CODE SETBACKS
ARRAY DETAIL
A B C D
AZIMUTH 270°90°
TILT ANGLE 27°27°
MODULE COUNT 14 14
90
120
150180210
240
270
300
330
0
30
60
W E
S
N
80
70
50
4O
2010350
320310
290
280
260
250
230220
200190 170160
140
130
110
100
340
AZIMUTH
180
SITE INDEX**AC DISCONNECT LOCATED 10' OR
LESS FROM UTILITY METER
110'
300'
190'
180'
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
UTILITY METER & MSP
INVERTER & DC DISCONNECT
37'-4"
52'-9"
37'-4"
52'-9"
JUNCTION BOX
CONDUIT RUN
PV MODULES
CONFIDENTIAL - THE INFORMATION
HEREIN CONTAINED SHALL NOT BE
USED FOR THE BENEFIT OF ANYONE
EXCEPT PORTICADE CONSTRUCTION
NOR SHALL IT BE DISCLOSED IN
WHOLE OR IN PART TO OTHERS
OUTSIDE RECIPIENTS
ORGANIZATION, EXCEPT IN
CONNECTION WITH THE SALE AND
USE OF THE RESPECTIVE
EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF DBM SOLAR DESIGN
AND CONSULTING COMPANY, LLC
SI
T
E
I
N
F
O
R
M
A
T
I
O
N
:
Th
e
G
a
t
e
s
A
p
a
r
t
m
e
n
t
s
N
o
r
t
h
C
l
u
b
h
o
u
s
e
37
0
W
7
t
h
S
,
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
SY
S
T
E
M
I
N
F
O
R
M
A
T
I
O
N
:
9.
1
k
W
DBM SOLAR DESIGN AND
CONSULTING COMPANY, LLC
P: (801) 690-4873
E: SUPPORT@DBMSOLAR.COM
WWW.DBMSOLAR.COM
PROJECT #
2020-PORT
DATE:
11/24/2020
DESIGNED BY:
J. Fairchild
SHEET NAME:
PAGE #REVISION:
1PV02
PROPERTY DETAIL
12/07/2020
VSE Project Number: U2783-0046-201
Firm License Number: C2269
Vector Structural Engineering has reviewed the existing structure
with loading from the solar array and lag screw connections to the
existing framing. The design of the racking system, connections,
and all other structure is by others. Mechanical, architectural, and
all other nonstructural aspects of the design are by others.
Electrical is by others, unless stamped by Dean Levorsen.
Solar panels and rails are designed for snow loads of 35 pounds per square foot.