HomeMy WebLinkAboutIMAGE REDLINED - 20-00560 - 1120 Monroe Dr - Basement EntranceAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 1120 Monroe Dr - Basement FinishAddress : 1120 Monroe DrRecord Type : Single Family - RemodelDocument Filename : 9CC1B887-8E7D-4296-A5A4-B2E814C51975.jpeg Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 20-00560 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Free text Larry Beesley : Building Open 1 Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if<11") Pg 1 Free text Larry Beesley : Building Open 1 Handrails (34' to 38' above stair nosing)R311.7 Pg 1 Free text Larry Beesley : Building Open 1 36" minimum Pg 1 Free text Larry Beesley : Building Open 1 The landing must be 36" in the direction of travel. Pg 1 Free text Larry Beesley : Building Open 1 Guardrails complying with R312 Pg 1 Free text Larry Beesley : Building Open 1 Maybe required. Single Family - Remodel If the floor of the landing at the bottom of the stairs is 30" or lower it will need a guardrail. It would be recommended that you put a good French drain in the landing for water orsnow . The hand rail is only required on one side of stairs. Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if <11") Handrails (34' to 38' above stair nosing)R311.7 36" minimum The landing must be 36" in the direction of travel. Guardrails complying with R312 Maybe required.