FIRE ALARM SUBMITTAL - 19-00727 - Spori Annex - Ceramic & Sculpture Labs
FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 Spori Annex Building 525 South Center Street Rexburg, ID. 83460 Spori Annex BYU-Idaho Fire Alarm System Submittal & Drawings PROJECT Equipment Manufacturer: Gamewell-FCI Spori Annex Building Authorized Distributor: Nelson Fire Systems BYU-Idaho 1481 S Major St Fire Alarm System SLC, UT 84115 801-468-8300... Spori Annex Building 525 South Center Street Rexburg, ID. 83460 TABLE OF CONTENTS Data Sheet Part No. Description Gamewell-FCI E3 Series Emergency Evacuation System Gamewell-FCI ILI-MB-E3 E3 Series Intelligent Loop Module Gamewell-FCI ASM-16 E3 Series Auxiliary Relay Gamewell-FCI LCD-E3 E3 Series LCD Display Gamewell-FCI PM-9 E3 Series Power Supply Gamewell-FCI INI-VGX-UTP E3 Series Voice Gateway Gamewell-FCI INCC-MIC E3 Series Microphone Gamewell-FCI AM-50 E3 Series Voice Amplifier Gamewell-FCI MMO-6SF Multi-Mod Signal Module Gamewell-FCI ASD-PL3/B300-6 Addressable Photo Smoke Detector w/Base Gamewell-FCI MS-7AF Addressable Pull Station Gamewell-FCI AMM-4F Addressable Monitor Module Gamewell-FCI PR-3 Relay Gamewell-FCI SPSWL White Speaker/Strobe – Wall Mount Gamewell-FCI SPSRK Red Weatherproof Speaker/Strobe – Wall Mount Gamewell-FCI P2RK Red Weatherproof Horn/Strobe – Wall Mount Gamewell-FCI HPFF8 NAC Power Supply Battery Calculations E3 System Battery Calc HPFF8 Battery Calc CKT Voltage Drops Drawings Sheet No. Description Cover Page FA-C-01 Fire Alarm Cover Riser Diagram FA-R-01 Fire Alarm Riser and Matrix Building FA-1-01 Addressable Circuits Building FA-1-02 Notification Circuits Building FA-1-03 Addressable Numbers E3 Series with LCD-SLP Display E3 Series with LCD-E3 Display E3 Series® Control Panel Expandable Emergency Evacuation System Analog and Networking Systems General The E3 Series® Expandable Emergency Evacuation System by Gamewell-FCI is in the forefront of the latest generation of fire alarm control panels. The E3 Series System is designed for use in virtually any application because it features a modular assembly that is configured per project requirements. Employing the new high-speed Velociti® sensors, the E3 Series provides previously unattainable polling speed and response together with the flexibility demanded by today’s emergency evacuation systems. In addition to the sensors’ high-speed polling rate, the Velociti Series of sensors feature bi-polar LEDs that flash green for normal polling, and light red steadily to indicate an alarm. The E3 Series is equipped with an 80-character LCD-E3 alphanumeric LCD display or 4.3” color touchscreen LCD-SLP display. Up to six keyboard LCD displays may be remotely located. In addition, you can install five of the familiar LCD-7100/RAN-7100 remote displays. The displays show instant system status information and can be connected in any desired area of an installation. FEATURES & BENEFITS • Styles 4, 6, or 7* signaling line circuits • IBC Seismic Certified • Listed under UL® Standard 864, 9th Edition • Listed under UL Standard UL2572 for Mass Notification • UL Listed for smoke control (dedicated and non-dedicated) when properly configured • UL Listed and FM Approved for Pre- action/Deluge and Agent Releasing • Two to 244 SLCs each supporting 159 sensors, 159 modules and 159 addressable sounder bases • 625K bits per second ARCNET communications using wire, fiber, or mixed configurations for installation flexibility • High-speed 32 bit processor and 8100 event history log • Advanced Boolean logic-based programming such as AND, OR, NOT, time delay and calendar functions configurable via computer programming • Supports up to (16), ASM-16 addressable switch or ANU-48 LED driver modules per ILI- MB-E3/ILI95-MB-E3 •Two Class A, Style Z or Class B, Style Y, notification appliance circuits rated at 2.0 amps. per circuit •Integral city connection • Up to 9 levels of sensitivity adjustment • Flexible 115,200 baud high speed RS-232 interface • 40 character user- defined text per device •Supports the following: - 15 LCD-SLP displays/ annunciators - 6 LCD-E3 displays/ annunciators - 5 LCD-7100/RAN-7100 remote LED annunciators per ILI-MB-E3/ ILI95-MB-E3 • Polls 318 devices in less than two seconds • Activate up to 159 outputs in less than five seconds • LED’s blink associated device address during Walk Test. • Fully digital, high- precision protocol •Drift compensation • Pre-Alarm adjustable between 15 levels for both Alert and Action • Day/night automatic sensing adjustment •Sensitivity windows • Ion 0.05 - 2% obscuration • Photo 1 - 3% obscuration • Laser 0.02 - 2% obscuration • MCS Acclimate 2.5 - 4%, also self- adjustable options: 1- 2%, 2-3%, 3-4% •HARSH 1-3% obscuration • Each Loop Card has its own integral processor providing maximum survivability on loss of any other component. SLC provides full response on loss of any other system processor •Optional programmable switches can be configured to enable, disable or group any combination of output devices • Integrated point or Grouped Cross Zoning allows for numerous devices installed at any location to cooperate and determine alarm condition • Automatic detector sensitivity testing •Signals DIRTY and VERY DIRTY detector maintenance alerts 2 General A high-speed 32-bit processor can easily implement a wide array of applications used in small office buildings or used in multi-complex, high-rise installations. The 64 node networking is made possible by 625K bits per second ARCNET communications using twisted-pair copper cable, fiber-optic cable, or a combination of both. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. The basic E3 Series is equipped with the following modules: • PM-9 Power Supply • ASM-16 (Addressable Switch Module) • ILI-MB-E3/ILI95-MB-E3 (Intelligent Loop Interface-Main Board) • ILI-S-E3/ILI95-S-E3 (Intelligent Loop Interface- Expansion Board) • LCD-E3 (LCD Keypad Display) The ASM-16 features 16 software programmable switches, each accompanied by red, green and yellow LEDs that can be programmed to indicate the operation of the switches. Additional ASM-16 modules may be added to expand the operation to a plateau previously unimagined. The Intelligent Loop Interface - Expansion Board (ILI- S-E3/ILI95-S-E3 provides the E3 Series control panel with two additional electrically isolated signaling line circuits. The layout is similar to the ILI-MB-E3/ILI95- MB-E3 with the exception that a number of components are omitted. It occupies one node on the Broadband network. Each ILI-MB-E3/ILI95-MB-E3 can support as many as sixteen ANU-48 LED Driver modules supporting hundreds of LEDs on a third party graphic annunciator to use for remote annunciation. The ANU-48 modules may be installed in any Listed remote annunciator. It can be remotely located via an RS-485 serial interface. An array of cabinets allows for neat, compact, attractive installations. Installation The E3 Series Expandable Emergency Evacuation System offers four cabinet size options. A typical cabinet includes a backbox, an inner door, and an outer door. The E3 Series cabinet assembly is a compact 19 3/8” (49 cm) wide, wall-mounted enclosure. • Cabinet A includes the following four options: - Cabinet A1 inner door mounted to the backbox. The backbox houses one NGA module. - Cabinet A2 inner door mounted to the backbox. The backbox houses one LCD-E3 module. - Two or three-bay inner door mounted to the backbox. - The backbox typically houses one LCD-E3, or one NGA, and one or two ASM-16 modules. • Cabinet B contains a space for the following modules installed inside the backbox: Additional module options mounted on the backbox include the following: The 2-bay inner door houses one LCD-E3 module and one ASM-16 module. • Both Cabinets C and D include the following: - Pre-assembled outer door that provides visibility to the fire fighter’s phone handset and a microphone voice messaging system. - Two inner door panel selections that may contain optional modules to meet the facility operation requirements. In the Cabinet B, C and D backboxes, the ANX appears in the same place as the ILI-MB-E3/ILI95-MB-E3 and PM-9/PM-9G. For information on the installation instructions for any of the E3 Series cabinets, refer to the E3 Series® Expandable Emergency Evacuation Manual, Part Number: LS10080-051GF-E. For other options including information on the system’s compatibility with the retrofit equipment, refer to the panel's installation manual, P/N:LS10080- 051GF-E or the Compatibility Addendum for Gamewell-FCI Manuals, P/N: 9000-0427-L8. Ordering Information ILI-MB-E3: Intelligent Loop Interface-Main Board ILI95-MB-E3: Intelligent Loop Interface-Main Board ILI-S-E3: Intelligent Loop Interface-Expansion Board ILI95-S-E3: Intelligent Loop Interface-Expansion Board ANX-SR: Addressable Node Expander-Single Ring ANX-MR-FO: Addressable Node Expander-Multi-Ring Fiber Optic ANX-MR-UTP: Addressable Node Expander-Multi- Ring Twisted-pair LCD-E3: LCD-E3, LCD Keypad Display LCD-SLP: LCD Color Touchscreen with five programmable switches RPT-E3-UTP: Network Repeater, unshielded, twisted- pair FML-E3: Multi-Mode Fiber-Optic Module FSL-E3: Single-Mode Fiber-Optic Module DACT-E3: Digital Alarm Communicator Transmitter ANU-48: ANU-48 LED Driver Module ASM-16: Addressable Switch Module NGA: LCD Network Graphic Annunciator PM-9: Power Supply Module, 120 VAC PM-9G: Power Supply Module, 220/240 VAC LCD-7100: Remote LCD Display RAN-7100: Remote LCD Display Note: For additional information on the cabinets, refer to the E3 Series Cabinets data sheet (Part Number: 9020-0649). - ILI-MB-E3 - PM-9 - ILI95-MB-E3 - PM-9G - ANX - DACT-E3 - ILI-S-E3 - ILI95-S-E3 - RPT-E3-UTP - E3 Series® Control Panel Technical Specifications 9020-0637 | S | 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s E3 Series® Control Panel and other products available by visiting www.Gamewell-FCI.com Seismic Battery Bracket Kits For information on the types of Seismic Battery Bracket Kits that are available, the Seismic Battery Bracket Kit Part Numbers and the Installation Instructions, refer to the following documents: • Seismic Battery Bracket Installation Guide, P/N: 53839 • E3 Series Cabinets Data Sheet, P/N: 9020-0649 SYSTEM Operating Voltage: 24 VDC Operating Temperature: Not to exceed the range of 32°- 120° F (0 -49° C) Relative Humidity: Not to exceed 93%, non- condensing at 90° F (32° C) Primary Power Supply: 9 amps @ 55 AH capacity TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The E3 Series fire alarm control panel is designed to comply with the following standards: UL Standards UL 864 9th Edition: Automatic Fire Detector Alarm Manual Fire Alarm Waterflow Alarm Supervisory Releasing Device Service Releasing/Pre-Action Deluge Releasing/Agent Releasing Automatic Smoke Alarm, Non-coded and Master Coded Operation UUKL for Smoke Control UL 2572 for Mass Notification Systems NFPA Standards NFPA 13 - Standard for Installation of Sprinkler Systems NFPA 16 - Standard for Foam-Water Sprinkler and Foam Water Spray Systems NFPA 72 - National Fire Alarm Code: Central Station Fire Alarm Systems Auxiliary Fire Alarm Systems Proprietary Fire Alarm Systems Local Fire Alarm Systems Remote Station Fire Alarm Systems NFPA 13 Sprinkler NFPA 12A Halon 1301 NFPA 15 Water Spray NFPA 16 Foam Water NFPA 750 Water Mist NFPA 2001 Clean Agent NFPA 12 CO2 Carbon Dioxide NFPA 17 Dry Chemical/17A Wet Chemical Seismic Codes International Building Code IBC 2013 IBC 2009 IBC 2006 IBC 2003 IBC 2000 (Seismic) California Building Code CBC 2007 (Seismic) STANDARDS The E3 Series Control Panel is designed to comply with the following standards: UL Standards: UL 864 9th Edition UL 2572 for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S1869, 2572 for Mass Notification FM: 3025415 MEA FDNY: 6175, COA #: 231-06-E CSFM: 7165-1703:0125 City of Chicago: Class 1, Class 2, High Rise City of Denver Approved The VMC Group, Reference Certificate of Compliance: VMA-45894-02C (Revision 1) ISO 9001 Certification GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0605 Rev. M page 1 of 2 ILI-E3 Series Intelligent Loop Interface-Main Board APPROVED FM 3025415S1869 SIGNALING City of Chicago Approved City of Denver ApprovedClass 1 Class 2 High Rise 7165-1703:0125 FDNY: COA # 231-06-E MEAApproved Description ILI-MB-E3The Intelligent Loop Interface-Main Board (ILI-MB-E3) is the main interface for the E3 Series® product line. With its state-of-the-art 32 bit RISC processor, this compact “panel on a board” provides a powerful addition to Gamewell- FCI’s single pair conductor solutions. The ILI-E3 Series is used in the following systems. • E3 Series Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System This intuitive design provides the following features: • 2 signaling line circuits • auxiliary power output • local energy city box output • auxiliary relay functions • 2 notification application circuits These features, combined with the built-in network and the serial protocols, allow this module to support a host of new and existing products, resulting in a building block approach to the fire alarm panel design. The ILI-MB-E3 is network ready and occupies 1 of 64 nodes operating at 625K baud. In addition, the Address- able Node Expander (ANX) board expands the network to 122 nodes. When this sub-assembly is integrated with proven Broadband components, the result is a flexible yet powerful integrated audio solution. When the system trans- mits to remote locations, the optional RPT-E3 provides the ILI-MB-E3 with valuable signal boosting and transient pro- tection, as well as connectivity using both wire and fiber- optic cables. The ILI-MB-E3 provides 2 signaling line circuits and termi- nals for the connections to up to 159 detectors and 159 modules per SLC in Velociti®. In CLIP™ mode, each SLC supports 99 detectors and 98 modules. The RS-485 inter- face can support up to a total of 6 LCD-E3 modules, 16 ASM-16, and/or 16 ANU-48 remote LED driver modules. The ILI-MB-E3 relay outputs include system alarm, super- visory, and system trouble contacts. The ILI-MB-E3 pro- vides output for a local energy city master box or remote location which is non power-limited. All other wiring is Class 2 power-limited. CLIP™ is a trademark of System Sensor. E3 Series®, NetSOLO® and Velociti® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. ILI-MB-E3 Features ILI-MB-E3 and ILI-S-E3: • Listed under UL ® Standard 864, 9th Edition.• Listed under UL Standard UL2572 for Mass Notification.• Network ready integral 625K baud ARCNET. • Supports 115.2K baud RS-232. • Provides signaling line circuits with the following: - Two Class A, Style 6, 7* or Class B, Style 4 circuits. - 40 Character user-defined text per device. - Capacity of 159 sensors and 159 addressable modules per circuit. • Includes 4100 Event History Log. *Style 7 wiring requires the use of the System Sensor M500X Isolator Modules. ILI-MB-E3 Only:• Two notification appliance circuits, Class “A”, Style Z or Class B, Style Y rated at 2.0 amps. per circuit. • RS-485 supporting 16 ASM-16 switch modules and/or ANU-48 LED driver modules. • Alarm, trouble, and supervisory dry contacts Form “C”, rated at 2 amp. @ 30 VDC (resistive). • Supports six local/remote LCD-E3 annunciators and five LCD-7100/RAN-7100 remote LED annunciators. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189020-0605 Rev. M page 2 of 2 www.gamewell-fci.com ILI-S-E3 ILI-S-E3 The Intelligent Loop Interface - Expansion Board (ILI-S-E3) provides the E3 Series control panel with 2 additional sig- naling line circuits. The layout is similar to the ILI-MB-E3 except a number of components are omitted. The ILI-S-E3 occupies one node on the Broadband network. The ILI-S- E3 provides 2 signaling line circuits and terminals for the connections to up to 159 detectors and 159 modules per SLC in Velociti mode. In clip mode, each SLC supports 99 detectors and 98 modules. Installation Typically, the ILI-MB-E3 or ILI-S-E3 can be mounted in the following E3 Series cabinets: • Cabinet B and D, backbox • Cabinet B, B-Slim-E3 sub-assembly plate • Cabinet C, E3-ILI-C sub-assembly plate • Cabinet C, E3-INCC-C sub-assembly plate • Cabinet C, E3-INX-C sub-assembly plate • Cabinet D, E3-INCC-D sub-assembly plate • Cabinet D, E3-INX-D sub-assembly plate For instructions on the installation of the ILI-MB-E3 or ILI-S-E3, refer to the following documents: • E3 Series ® Expandable Emergency Evacuation Installation/Operation Manual, Part Number: 9000-0574 • ILI-MB-E3 Installation Instructions, Part Number: 9000-0579 • ILI-S-E3 Installation Instructions, Part Number: 9000-0569 For information on the ILI95-MB-E3 and ILI95-S-E3, refer to the ILI95-E3 Series Data Sheet, Part Number, 9021-60336. For information on the ANX, refer to the ANX Data Sheet, Part Number, 9021-60497. Specifications ILI-MB-E3 Operating Current:0.081 amp Alarm Current:0.150 amp max. ILI-S-E3 Operating Current:0.118 amp Alarm Current:0.119 amp ILI-MB-E3 and ILI-S-E3 Operating Voltage:24 VDC FWR (from the PM-9/ PM-9G Power Supply). Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93%, non-condensing at 90° F (32° C) Supervised Class 2 Power-Limited SLC 40 Ohms maximum line impedance 0.5 µf maximum line capacitance Ordering Information Part Number Description ILI-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0554 Rev. O page 1 of 1 ASM-16 ASM-16 Addressable Switch Module Rear View Front View APPROVED FM 3017416S1869 SIGNALING Approved City of Chicago Class 1 Class 2High Rise 7165-1703:01257170-1703:0126 FDNY: COA # 231-06-E MEAApproved City of Denver Approved Description •The Gamewell-FCI, ASM-16 Addressable Switch Module serves as the point of interface between an operator and the system’s audio evacuation, fire fighter intercom, and building control circuits. It is a component of the following systems: • E3 Series ® Expandable Emergency Evacuation System •E3 Series Combined Fire and Mass Notification System• E3 Series Broadband Voice Evacuation System • S3 Series (Small Addressable Fire Alarm Control Panel)•NetSOLO® System •The ASM-16 is a configurable switch input sub-assembly with 16 switches and 48 status LEDs. It may be remotely located via the RS-485 serial interface. Each ASM-16addressable switch module has 16 push-button switches that can be programmed to serve any function the applica- tion demands. •An ASM-16 switch can be programmed to operate as any of the following functions:• speaker circuit switch • fire fighter phone switch • auxiliary control switch (using a bank of two switches, one switch each for the on-off-auto functions). • switches with custom-defined functions: - system reset - system silence - system acknowledge- all-call, phone patch - lamp test, alarm tone on - manual select, etc. •Each ASM-16 switch also has three fully programmableLEDs that appear in red, yellow, and green. These LEDscan be programmed to work in concert with their associ-ated push-button switch or they can be programmed towork independently as status indicators (e.g. on, off, normal, etc.). •An INI-VGC, ILI-MB-E3/ILI95-MB-E3 or SLP (Smart LoopPanel) can accommodate up to 16 ASM-16 modules for atotal of 256 switches and 768 LEDs. •Specifications •Operating Voltage:24 VDC (nominal) (from the PM-9/PM-9G power supply)Operating Current:0.011 amp. (with no LEDs lit)Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93% (non-condensing) at 90° F (32° C) • E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL ® Standard UL2572 for Mass Notification. • Each INI-VGC supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each ILI-MB-E3/ILI95-MB-E3 supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each SLP supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each ASM-16 switch has 3 fully programmable status, indicating LEDS: red, yellow, and green. • All switch functions are fully software programmable. • Slip-in label inserts allow easily modified switch designations. Ordering Information Part Number Description 1100-0455 Programmable Addressable Switch Module GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0606 Rev. I page 1 of 1 LCD-E3 LCD Keypad Display APPROVED FM City of Chicago Approved City ofDenver Approved3025415Class 1Class 2 High Rise S1869 SIGNALING 7165-1703:0125 ApprovedMEA FDNY: COA #6077 Description The LCD-E3 provides the main panel display of the E3 Series® Expandable Emergency Evacuation System with indicating LEDs and operating switches. Up to six (6), LCD-E3 displays may be locally or remotely located from the panel via a local RS-485 bus of the E3 Series, ILI-MB- E3/ILI95-MB-E3 or the S3 Series, SLP (Smart Loop Panel) sub-assembly. The LCD-E3 includes an LCD display for the system status and the following switches and LED indicators: Switches • Alarm acknowledge • System reset/lamp test • Trouble acknowledge • Function buttons: - menu/back - back space/edit - OK • Signal silence • 12 button keypad LED Indicators • AC Power On (green) • Power Fault (yellow) • Alarm (red) • Ground Fault (yellow) • Supervisory (yellow) • System Silenced (yellow) • System Trouble (yellow) Installation Options The LCD-E3 is adaptable for installation in any of the following E3 Series System cabinets. Cabinet Part Number • “A” size cabinet, inner door E3ID2-A • “A2” flush cabinet E3BB-FLUSH-LCD • “A2” size cabinet, inner door E3ID-A2 • “B” size cabinet, inner door E3ID2-B • B-Slim cabinet, outer door E3BB-RBSLIM • 7200 B Retrofit, inner door 7200-B-RETROFIT • IF600 Retrofit, outer door IF600-RETROFIT • “C” size cabinet, inner door E3ID2-C • 600XL Retrofit, inner door 600XL-RETROFIT • 7200 C Retrofit, inner door 7200-C-RETROFIT • “D” size cabinet, inner door E3ID2-D Specifications Operating Voltage:24 VDC FWR (from PM-9 power supply) Operating Current:0.024 amp Alarm Current:0.028 amp Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93%, non-condensing at 90° F (32° C) E3 Series® is a registered trademark of Honeywell International Inc. LCD-E3 Features •Listed under UL Standard 864, 9th Edition. • Provides an 80-character display of system events together with indicating LEDs and control switches. • The E3 Series, ILI-MB-E3/ILI95-MB-E3 or S3 Series, SLP can support up to six LCD-E3 displays, any or all of which may be remotely located via the RS-485 serial interface. • Offers a legible backlit LED display, with low power con- sumption. Ordering Information Part Number Description LCD-E3 LCD keypad display GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0555 Rev. O page 1 of 1 PM-9 PM-9 Power Supply S1869 Vol. 14 S1949 Vol. 19 APPROVED FM 3017416 7165-1703:0125 Approved City of DENVERApproved Class 1 Class 2 High Rise Chicago City ofSIGNALING FDNY: COA #6077 MEAApproved Description •The Gamewell-FCI, PM-9 Power Supply is a switching power supply that provides 9 amperes of filtered and regu- lated 24 VDC (nominal). It provides the power to the INX Transponder assembly and all of the E3 Series compo- nents. It is a component of the following systems. • E3 Series ® Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System • NetSOLO ® System •The PM-9 has an internal battery charging circuit capable of maintaining up to 55 A/H batteries. This module is designed for use with the Gamewell-FCI distributed audio networks. •Installation Typically, the PM-9 Module can be mounted in the follow- ing E3 Series cabinets: • Cabinet B and D, backbox • Cabinet C, INX-E3 sub-assembly plate • Cabinet C, INCC-E3 sub-assembly plate • Cabinet D, E3-INX-D Plate • Cabinet D, E3-ILI-D Plate •For information on the installation of the PM-9, refer to the following documents: • E3 Series Expandable Emergency Evacuation Installation/Operating Manual, P/N: 9000-0574 • PM-9 Installation Instructions, P/N: 9000-0548 • Mass Notification System Manual, P/N:LS10013-000GF-E •Specifications •Input Voltage:120 VAC 60 Hz @ 3.5 A. max. Output Voltage:24 VDC (nominal) FWR Output Current:9 amperes Output Current:1 ampere battery charging current Alarm Current:0.050 amp Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93% (non-condensing) at 90° F (32° C) Dimensions:10 1/2” W x 5” H x 2” D (27 x 13 x 5 cm) E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL Standard UL2572 for Mass Notification. • Includes 9 ampere, filtered, regulated power supply. • Provides 1 ampere battery charging current. • Offers energy and space saving switching technology. • Contains an integral battery charger capable of recharging up to 55 AH batteries. (Batteries not furnished). Ordering Information Part Number Description PM-9 Power supply 29229 AC Line Filter Kit PM-9 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2007 Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0648 Rev. C1 page 1 of 2 INI-VG Series INI-VG Command Center Voice Gateway - Description The following sub-assemblies are components of the E3 Broadband Audio Evacuation System and optional com- ponents of the E3 Series™ Expandable Emergency Evac- uation System: •INI-VGC •INI-VGE •INI-VGX INI-VGC The INI-VGC Voice Gateway Module provides command and control functions for the INCC Command Center. The INCC serves as the point of interface between an operator and the system’s audio evacuation, fire fighter intercom, and building control circuits. A typical INCC assembly consists of an Intelligent Network Interface-Voice Gateway (INI-VGC) Module and one or more Addressable Switch Modules (ASM-16). Each INI- VGC can support up to sixteen (16), ANU-48 LED Driver Modules or ASM-16s for a total of 256 fully programmable switches and 768 LEDs (red, yellow, and green). The INI-VGC occupies a single node on the E3 Broad- band network and is connected by a single pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. The INI-VGC-UTP is not equipped with fiber-optic connectors. The INCC Command Center’s INI-VGC module also pro- vides connections for an optional emergency voice page microphone as well as a Fire Fighter telephone handset. The INI-VGC is a fully digital voice/tone generator using state-of-the-art Digital Signal Processing (DSP) technol- ogy to produce the clearest, most audible signal possible. The INI-VGC provides an output to a local speaker for message verification and testing. E3 Series™ is a trademark of Honeywell International Inc. Features The INI-VG Series include the following features: • Listed under UL Standard 864, 9th Edition. • All communication signals and control-by-event sequences over twisted, unshielded pair of wires or fiber-optic cable. • Distributed architecture, including Style 7 wiring configuration, allows system components to continue normal operation with NO loss of function during single line fault conditions. • Each INI-VGC or INI-VGE supports up to sixteen (16), ANU-48 LED drivers or ASM-16 switch modules for a total of 256 switches. • INI-VGC connects to a voice page microphone and fire fighter’s handset. • Redundant command centers with microphone and fire fighter’s handset easily configured by adding INCCs. • Advanced digital signal processor (DSP) technology for efficient audio compression and filtering. • Network data transfer rate at 625K baud. The INI-VGX includes the following features: • Software-programmable multi-channel digital audio applications. • One Style 4 signaling line circuit (SLC) supporting up to thirty-two (32), addressable speaker circuits. • AOM-MUXF for dual channel) and sixteen (16), addressable phone circuits (AOM-TELF). • Supports up to 150 watts of audio power (AM-50 amplifier modules) with additional 50 watts of standby in a single, compact wall- mounted cabinet. • 16 message capacity with up to 3 minute duration per INX and messages are easily field-configured via a laptop computer. SIGNALING S1869 3006578 APPROVED FM 7300-0694:231 Approved Class 1 Class 2 High Rise Chicago City of 255-02-E MEA Approved Approved City of DENVER An ISO 9000-2000 Company INI-VG GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0648 Rev. C1 page 2 of 2 www.gamewell-fci.com INI-VGC (Continued) The E3 Broadband Audio Evacuation System is a peer-to- peer, self regenerating, token ring network comprised of up to sixty-four (64), individual nodes. Each E3 Broadband node can be spaced on the network a maximum distance of 3,000 feet (914.4 m) or up to an 8dB loss using fiber-optic cable. Built-in isolation at each node permits Style 4, 6, and 7 net- work configurations. INI-VGE The INI-VGE Voice Gateway Module provides command and control functions for the INCC Command Center. It provides bulk amplification. A typical INCC assembly consists of an Intelligent Network Interface-Voice Gateway (INI-VGE) Module and one or more Addressable Switch Modules (ASM-16). Each INI- VGE can support up to six (6), ASM-16s for a total of 96 fully programmable switches and 288 LEDs (red, yellow, and green). The INI-VGE occupies a single node on the E3 Classic net- work and is connected by a single pair of twisted, unshielded wire, fiber-optic cable or any combination of the two. The INI-VGE-UTP is not equipped with fiber-optic con- nectors. The INCC Command Center’s INI-VGE Module also pro- vides connections for an optional emergency voice page microphone as well as a fire fighter telephone handset. The INI-VGE is a fully digital voice/tone generator using state-of-the-art Digital Signal Processing (DSP) technology to produce the clearest, most audible signal possible. The INI-VGE provides an output capable of driving up to 20 Model AA-100 or AA-120 amplifiers. INI-VGX The INI-VGX Transponder Voice Gateway is a component of the E3 Broadband Audio Evacuation System and an optional component of the E3 Series Expandable Emer- gency Evacuation System. It is a multi-function module that incorporates: • Network interface using twisted, unshielded wire or fiber-optic cable. • Fully digital message generator. • One (1) signaling line circuit for local peripheral devices. • Local fire fighter phone riser. It occupies a single DIP switch selectable address on the network and provides termination points for the network connection using either a pair of twisted, non-shielded wire (12 AWG max.) fiber-optic cable, or a combination of the two. The INI-VGX-UTP is not equipped with fiber-optic con- nectors. The INI-VGX provides command and control for up to four (4), AM-50, 50 watt amplifiers in a single cabinet. The INI- VGX uses advanced Digital Signal Processing (DSP) tech- nology for audio compression and filtering allowing E3 Broadband to produce the clearest audio possible. Back- ground noise is automatically filtered during voice paging and fire fighter communications increasing audibility and eliminating the need for Push-to-Talk devices. Specifications INI-VGC, INI-VGE and INI-VGX Operating Voltage:24 VDC (nominal) Operating Current:0.150 amp. supervisory and alarm Operating Temperature:32° to 120° F (0 to 49° C) Relative Humidity:0 to 93% (non-condensing) Protocol:Asynchronous with half-duplex data flow Speed:RS-232 up to 64 KBps RS-485 up to 128 KBps St connectors*:Up to 200 microns (multimode), Optimized for 62.5/125 microns *St Connectors are omitted on the INI-VG-UTP Series. *Model INI-VGC only Ordering Information INI-VGC Model Description INI-VGC Command center voice gateway INI-VGC-UTP Command center—(unshielded twisted-pair only) INI-VGE INI-VGE Command center voice gateway INI-VGE-UTP Command center (unshielded twisted-pair only) INI-VGX INI-VGX Transponder voice gateway INI-VGX-UTP Transponder voice gateway (unshielded twisted-pair) GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2011 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60402 Rev. B page 1 of 1 INCC-MIC Paging Microphone ModuleDescription • The INCC-MIC Paging Microphone Module is a com- ponent of the NetSOLO® and E3 Series® fire alarm and voice evacuation systems. The INCC-MIC microphone provides a cost-effective microphone interface module for paging. Installed with the ASM-16 Addressable Switch Module, it pro- vides easy paging to selected speaker zones with visual indications of paging and zone status. Installation The INCC-MIC Paging Microphone Module can be installed in any of the following types of E3 Series cabinets: • Cabinet AA • Cabinet B • Cabinet C • Cabinet D Note: Gamewell-FCI recommends that you install the speakers at 4 ft. (1.2 m) or more from the microphone. Specifications INCC-MIC Paging Microphone Module Microphone Box Durable gauge steel construction with microphone holder Dimensions:5.5” W x 6.5” H x 2.75” D (14 W x 16.5 H x 7 D cm) E3 Series® is a registered trademark of Honeywell International Inc. Shure® is a registered trademark of Shure Incorporated. Features • Delivers audio feedback cancellation • Contains a supervised microphone • Provides status bit activation when the micro- phone is in use • Offers an easy installation • Has a preassembled microphone box with a microphone holder • Includes a terminal block with an easy-to-use plug-in cable Ordering Information Part Number Description 1100-0452 Paging Microphone Module INCC-MIC An ISO 9001-2000 Company ApprovedFDNY: COA-#6077 MEA GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2015 Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0556 Rev. K1 page 1 of 2 AM-50 Series AM-50 Series Amplifiers SIGNALING S1869 Approved City of DENVER 3017416 APPROVED FM Approved Class 1 Class 2 High Rise Chicago City of FDNY: COA #6077 MEA Approved 7165-1703:0125 Description The Gamewell-FCI, AM-50 Series amplifiers are a 50 watt, digital, switching power amplifier. The following lists the 2 types of AM-50 Series amplifiers that may be ordered. • The AM-50-25 amplifier produces 25 VRMS audio output. • The AM-50-70 amplifier produces 70.7VRMS audio output. The amplifiers are components of the following E3 Series® Systems. • E3 Series Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System WARNING: AM-50 Series Amplifiers Node Restriction: The INI-VGX can support up to 4 AM-50 Series amplifiers with the same output voltage. However, you cannot wire an AM-50-25 amplifier and an AM-50-70 amplifier to the same INI-VGX Voice Gateway Node. Each AM-50 Series amplifier provides 2 speaker circuits that can be wired Style Y (Class “B”) or Style Z (Class “A”). The terminal connections can accommodate up to 12 AWG, twisted-pair, shielded wire. Both speaker circuits pro- duce a combined total of 50 watts of power. The 50 watts of power can be divided between the 2 integral Class A/B speaker circuits. The 2 speaker circuits may be individually activated and supervised by an INI-VGX Transponder Voice Gateway. The AM-50 Series amplifier can be programmed to broad- cast 16 messages generated from its local INI-VGX Voice Gateway. In addition, the AM-50 Series amplifiers produce superior clarity for intelligible LIVE voice paging. When the selected System Sensor, SpectrAlert® Advance Series speakers are used with the Manufacturer’s 520 Hz audiophile, the E3 Series® System is compliant with UL Standard 464 Low Frequency requirements. For additional information, refer to the SpectrAlert Advance Series Data Sheet, P/N:9021-60346. Installation As many as four AM-50 Series amplifiers can be installed in the following cabinets when supervised and controlled by an INI-VGX Voice Gateway. • Cabinet B, INX CAB-B • Cabinet C, INX-CAB-C • Cabinet D, INX-CAB-D E3 Series® and SpectrAlert® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories, Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL Standard UL2572 for Mass Notification. • Complies with UL Standard 464 for 520 Hz Low Frequency. • Provides digital, switching amplifier technology. • Produces 50 watts of digital power. • Includes 2 speaker circuits, wired Style Y (Class B) or Style Z (Class A). • Up to 4 AM-50 Series amplifiers with the same out- put voltage can be controlled by the INI-VGX voice gateway. AM-50-25 AM-50-70 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189020-0556 Rev. K1 page 2 of 2 www.gamewell-fci.com Description (Continued) The AM-50 Series amplifiers can be installed using the AM-50 Extender Plate whenever the E3 Series control panel is used in conjunction with the Autonomous Control Unit of the E3 Series Combined Fire and Mass Notification System. • Cabinet C, E3 INCC-CAB-C For additional information, refer to the E3 Series CombinedFire and Mass Notification Data Sheet, P/N:9021-60758 Specifications AM-50-25 Amplifier Operating Voltage:27.3 to 20.4 VDC Operating Current:0.086 amp normal standby Alarm Current:2.206 amp max. alarm @ 50 Watt Audio Output:50 watts max. @ 25 VRMS AM-50-70 Amplifier Operating Voltage:27.3 to 20.4 VDC Operating Current:0.049 amp normal standby Alarm Current:2.30 amp max. alarm @ 50 watt Audio Output:50 watts max. @ 70.7 VRMS AM-50 Series Amplifiers Relative Humidity:0 to 93% max., (non-con-densing) at 90° F (32° C) Operating Temperature:32° to 120° F (0° to 49° C) Dimensions:7 1/2” W x 3 1/2” H x 1 1/4” D (19 W x 9 H x 3 D cm) Ordering Information Part Number Description 1100-0456 AM-50-25, INX 25VRMS audio output, 50 watt amplifier AM-50-70 INX 70.7VRMS audio output, 50 watt amplifier GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.©2013 Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0634 Rev. D page 1 of 2 Velociti® Series MMO-6SF Multi-MOD Six Signal Output Module S1913 SIGNALING 7300-1703:01243023594APPROVED FM MEA Approved 219-02-E Vol. VI Description The Gamewell-FCI Velociti® Series, multi-mod six signal output module (MMO-6SF) provides six (6), Style Y (Class B) or three (3), Style Z (Class A) supervised control circuits suitable for a wide range of signaling applications. Each supervised circuit may be used as a: • Audio speaker circuit. • Notification applicance circuit. • Supervised control output. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The MMO-6SF connects to the signaling line circuits (SLC) of the Gamewell-FCI analog addressable series fire alarm control panels. Each of the MMO-6SF supervised control circuits occupies its own address on the system’s SLC allowing each to be fully programmable in its control-by- event sequence of operation. The address of the first supervised output circuit is set with a pair of rotary dials. Each remaining circuit is automati- cally assigned to its own subsequent address. The MMO- 6SF module includes an address disable jumper matrix that allows one, two, or three addresses to be turned off to free these addresses for other purposes. An additional jumper setting selects either Style Y or Style Z circuit con- figurations. A wide range of configurations are possible including 30 VDC, audio input at 25 or 70.7 VRMS, 125 VAC, etc. More than one circuit can share a power supply if the current capacity does not exceed the power supply’s output. Each output circuit on the MMO-6SF monitors its own con- nection to its power supply and will indicate a fault condi- tion by address if the power source should fail. The MMO- 6SF is also provided with short circuit monitoring to protect the external power source from short circuits on the notifi- cation appliance circuit wiring. This feature can be disabled per individual circuit if the application requires. Velociti® and E3 Series® are registered trademarks of Honeywell International Inc. Features • Each MMO-6SF module provides six (6), Style Y (Class B) or three (3), Style Z (Class A) individually address-able, individually programmable notification appliance or supervised output circuits • Removable wiring terminal blocks allow ease of installa-tion and servicing • Terminal blocks can accommodate 12 to 18 AWG wire • Flexible jumper configuration feature allowing up to three (3), output circuit addresses to be disabled • Accommodates multiple external power inputs • External power monitoring • Short circuit protection of external power supplies • Sources providing AC, DC, or audio inputs • Designed for use with Gamewell-FCI analog address-able series fire alarm control panels • Individual LED indicators* • Ideal for retrofit applications • Two (2), mounting cabinets available for two (2), (MBB-2 cabinet) to six (6), (MBB-6 cabinet) units Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189020-0634 Rev. D page 2 of 2 www.gamewell-fci.com Description (Continued) (Note: power supply monitoring must also be disabled in such cases.) Each circuit has its own status LED that flashes to indicate proper polling and lights steadily when the output has been activated. Two (2), multi-mod series units can be mounted in one MBB-2 cabinet. Additional mounting options include the MCH-6 chassis that can accommodate six multi-mod series modules. The MCH-6 chassis can be installed in a custom cabinet or can be mounted in the MBB-6 cabinet allowing up to six (6), multi-mod series modules in one cabinet. The MMO-6SF is ideal for applications where centralized location of circuits is required. As many as thirty-six (36), supervised output circuits may be located in a cabinet that is only 12.63” H x 24” W x 6.5” D in dimension saving valu- able wall space in mechanical rooms and electrical closets and reducing cost of installation. Specifications Operating Voltage:15-32 VDC Stand-by Current:2.25 mA Alarm Current:40 mA (with all six LEDs lit) Maximum IDC Wire Resistance: 25 Ohms Temperature Range:32° F to 120° F (0° to 49° C) Humidity 10 to 85% (non-condensing) Dimensions:6.8” H x 5.8” W x 1.25” D (17.3 x 14.7 x 3.2 cm) MBB-2 12.25” H x 9.25” W x 3.32” D (31.1 x 23.5 x 8.4 cm) MBB-6 12.63” H x 24” W x 6.5” D (32 x 60.1 x 16.5 cm) External Supply Voltage DC Voltage:18-28 Volts, Class 2 Power-Limited Ripple Voltage:0.1 Volts rms maximum Current:90 mA per module Contact Ratings Current Rating Maximum Voltage Load Description Application 3A 30 VDC Resistive Non-coded 2A 30 VDC Resistive Coded 1A 30 VDC Inductive (L/R= 2ms)Coded 0.5A 30 VDC Inductive (L/R= 5ms) Coded 0.9A 110 VDC Resistive Non-coded 0.9A 125 VAC Resistive Non-coded 0.7A 70.7 & VAC Inductive (PF= 0.35)Non-coded 0.5A 125 VAC Inductive (PF= 0.35) Non-coded Ordering Information Part Number Description MMO-6SF Multi-Mod 6 zone interface module MBB-2 Backbox, 2 unit MBB-6 Backbox, 6 unit, requires MCH-6 MCH-6 6-Unit mounting chassis ASD-PL2F/ASD-PTL2F ASD-PL2FR Velociti® Series 3 Detectors Photoelectric Detectors Addressable Devices Photoelectric Detector Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re-designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti® and CLIP™ protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL® Standard 268 7th Edition • Designed with a new profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by external magnet • Supports a low standby current • Provides rotary address switches (01-159) • Supplies optional relay, isolator, or sounder bases (standard or low frequency) • Includes dual LEDs for 360° visibility • Offers expanded color options 2 Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: “WH” suffix indicates Bright White color model. ASD-PL3: Photoelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV : Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: “IV” suffix indicates Flashscan and CLIP devices. “WH” suffix indicates bright white B501-WHITE: 4” Flangeless mounting base, bright white B501-WHITE-BP: 4” Flangeless mounting base bulk pack, bright white B501-IV: 4” Flangeless mounting base, ivory B300-6: 6” Flanged mounting base, bright white B300-6-IV: 6” Flanged mounting base, ivory B300-6-BP: 6” Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non-relay DNRW: Intelligent duct detector housing, non-relay, watertight Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6” Base, bright white TR300-IV: Accessory Flange Ring for B300 6” Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-Bl: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti® Series 3 Detectors Technical Specifications 9020-0617 | K | 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32° F to 122° F (0° C to 50° C) Photo in Duct Applications: -4° F to 158° F (-20° C to 70° C) Photo with Thermal: 32° F to 100° F (0° C to 38° C) Operating Humidity Range: 10% to 93% non-condensing Rate-of-Rise Detection: Responds to greater than 15°F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 STANDARDS The Velociti® Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0616 Rev. E page 1 of 2 MS-7 Series Non-Coded, Manual Fire Alarm Stations APPROVED FM 3023594 SIGNALING 7150-1703:0119 7150-1703:0170 7150-1703:0109 S2465 MEAApproved67-02-E Vol.VIII Description The Gamewell-FCI, MS-7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key lock/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a dou- ble action station designed for installation in the signalingline circuit of Gamewell-FCI analog addressable controlpanels. Activation of the station causes its assigned address to register at the control panel. The door containsan LED which flashes green in normal condition and lightssteady red when the station has been activated.* The sta- tion features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a single action station designed for installation in the signal- ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. The Velociti® Series stations use a communication proto- col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Features • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL ® Listed control panel • Both single and double action stations available • Tumbler lock for test and reset keyed alike with Gamewell-FCI controls • Surface or semi-flush mounting • Shock and vibration resistant • Stations (MS-7LOB) Listed for outdoor applications • Complies with ADA pull force requirements *Only the red LED is operative in panels that do not oper- ate in Velociti mode. MS-7 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189020-0616 Rev. E page 2 of 2 www.gamewell-fci.com MS-7S Single Action Station The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS-7 station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of singlepole contacts and screw terminals for connection to an ini- tiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell-FCIfire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil-ities are required. It consists of an MS-7LR mounted on aplate with an abort switch and LED indicators for system normal, and system activated status. MS-7LOB Double Action Station(Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-I/O backbox. In retrofit applications, the station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior stations may be surface mounted or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC-Plate Specifications Material:Lexan® Contact Ratings:0.25 amps. @ 30 VAC/VDC (resistive) Dimensions:5 5/8” H x 4 1/4” W x 1 1/4” D (14 x 10.1 x 3.2 cm) Operating Temperature (MS-7AF, MS-7ASF):32° to 120° F (0° to 49° C) (MS-7LOB):-30° to 150° F (-35° to 66° C) Relative Humidity (MS-7AF, MS-7ASF):10 to 93% (non-condensing) (MS-7LOB):85% ± 5% @ 86° ± 3.6° (30° ± 2° C) Alarm Current:.0030 amp. 0.007 for LED Supervisory Current (MS-7AF, MS-7ASF):.00030 amps. Ordering Information Part Number Description MS-7 Double action station MS-7AF**Velociti addressable double action station MS-7ASF**Velociti addressable single action station MS-7S Single action station, wire leads MS-7SP Double action station, English and Spanish instructions MS-7LR Agent release station, dual-action MS-7LRA Agent release station with abort switch, LED indicators, dual- action MS-7LOB Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O Indoor/outdoor use backbackbox SB-10 Surface backbox BG12TR Trim ring for semi-flush mount, plastic NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0624 Rev. E page 1 of 1 Velociti® Series AMM-4F Addressable Monitor Module 3023594APPROVED FM 7300-1703:0102 SIGNALING S1949 MEA Approved227-03-E Vol. IV Description The Gamewell-FCI Velociti® Series, addressable monitor module (AMM-4F) features a single Style D, Class A initiat- ing device circuit. It may also be configured as a Style B, Class B initiating circuit with end-of-line resistor. This mod- ule provides an address for any device or group of devices connected to this circuit. Any alarm initiating devices with normally open (N.O.) dry contacts, such as heat detectors, linear heat detection devices, 4-wire projected beam smoke detectors, 4-wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in this circuit. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-4F module is designed for installation in the sig- naling line circuit of any Gamewell-FCI analog addressable control panel. The initiating circuit of the AMM-4F has a maximum line resistance of 40 ohms, allowing the module to accommodate a number of initiating devices at a dis- tance from the module. The AMM-4F is designed to mount in a 4” square junction box 2 1/8” deep. The initiating device circuit of the AMM-4F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. Ordering Information Model Description AMM-4F Addressable monitor module, single circuit, Style D, Class A or Style BC/A and B Velociti® and E3 Series® are registered trademarks of Honeywell International Inc. Features • Compact size allows easy installation • Class A, Style D, or Class B, Style B initiating circuit • Visual rotary, decimel switch addressing (01-159) • 40 ohm line resistance for each initiating device circuit • Accommodates any N/O dry contact device • Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm* *Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Specifications Supervisory current:.000375 amps. (LED flashing) Alarm current:.005 amps. (LED lit) Operating temperature: 32° to 120° F (0° to 49° C) Relative humidity:10 to 93% (non-condensing) End-of-line resistor:47K ohms Dimensions:4 1/2” H x 4” W x 1 1/4” D (11.4 x 10.2 x 3.2 cm) AMM-4F Agency Listings Multi-Voltage Conventional Relays System Sensor’s multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-10T/20T and R-14T/24T Removable front cover on steel enclosure for R-10E/R-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure’s cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware • • • • • • • • • • The R-10T, R-20T, R-14T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-10T is a single FORM–C (SPDT) relay with a red activation LED, and the R-14T is a four-gang 1 FORM–C (SPDT) relay with four red activation LEDs. The R-20T is a single 2 FORM–C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM–C (DPDT) relay with four red activation LEDs. The R-10E/R-20E and R-14E/R-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure. The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-1/PR-2/PR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a red LED as a visible indication of relay coil energization. PR–3 is identical to PR–2, except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0372-005 • 3/07 • #1782 Specifications: R-10T/R-14T/R-20T/R-24T Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10T/R-14T) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20T/R-24T) Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10% – 93% non-condensing Dimensions R-10T/R-20T: 2.5˝L × 3.35˝W × 1.2˝H R-14T/R-24T: 10˝L × 3.35˝W × 1.2˝H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Specifications: R-10E/R-14E/ R-20E/R-24E Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10E/R-14E) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20E/R-24E) Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10% – 93% non-condensing Dimensions R-10E/R-20E: 5.1˝L × 3.75˝W × 2.5˝H R-14E/R-24E: 11˝L × 5.3˝W × 2.5˝H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Multi-Voltage Conventional Relay Specifications PR–1 E0LR–1 PR–3 PR–2 R–10T R–14T R-10E & R-20E Enclosure R-14E & R-24E Enclosure Specifications: PR-1 Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 120 VAC Operating Current 15 mA DC max. @ 24 VDC, 24 VAC, 120 VAC Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Dimensions 0.87˝H × 2.01˝W × 1.42˝D Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive Specifications: PR-2/PR-3 Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Dimensions 0.91˝H × 1.65˝W × 1.22˝D Contact Ratings 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) Specifications: EOLR-1 Operating Voltage 9 to 40 VDC Operating Current 20 mA DC max. Operating Temperature –22°F to 140°F (–30°C to 60°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30 VDC: 3 A max. (resistive load) GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60931 Rev. A page 1 of 3 Indoor Selectable-Output Speaker Strobes and Dual-Voltage Evacuation Speakers for Wall Applications L-SeriesIndoor Wall Speaker Strobes and Speakers APPROVED FM SIGNALING PENDING Description The L-Series indoor selectable-output speaker strobes and dual-voltage evacuation speakers offer a modern, aes- thetic plug-in design that reduce costly ground faults. The universal mounting plate can be used in wall installation applications and its flexible design enables the Installer to easily perform the following:• Pre-wire mounting plates. • Dress the wires.• Confirm wiring continuity before the Installer plugs-in the speakers. This product includes a protective plastic cover which shields exposed speaker components and prevents nicked wires. These devices enable faster installations by providing instant feedback to the Installer to ensure the following:• The wiring is properly connected. • The rotary switches are set to the selected voltage and power settings.• The 7 field-selectable candela settings are configured for wall speaker strobes. The low total harmonic distortion of the speaker offers both high-fidelity and high-volume sound output so that it can be used in high ambient noise applications. L-Series makes installation easyTo install the L-Series speakers or speaker strobe, do thefollowing: 1. Attach a universal mounting plate to a 4 x 4 x 2 1/8 inch backbox. Flush-mount applications do not require an extension ring. 2. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. 3. To attach the speaker or speaker strobe to the mount- ing plate, insert the product tabs into the mounting plate grooves. 4. Hinge the device into position to lock the product pins into the mounting plate terminals. 5. A catch will temporarily hold the device in place until you secure the device with a captured mounting screw. L-Series Speaker and Speaker StrobeSpecifications Architectural/Engineering Specifications General The L-Series speaker and speaker strobes shall mount toa 4 x 4 x 2 1/8-inch backbox. A universal mounting plateshall be used for the mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Features • Includes a plug-in feature to reduce ground faults and a protective cover to shield speaker components. • Contains a universal mounting plate with an on-board shorting spring that is used to test the wiring continuity before an installation. • No extension ring required. • Field-selectable candela settings on wall units: - 15 - 30 - 75 - 95 - 110 - 135 - 185 • Uses an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Provides a rotary switch that simplifies the field selection of speaker voltage (25) and 70.7 VRMS) and the follow-ing power settings: – 1/4 watt – 1/2 watt – 1 watt – 2 watts • Offers speakers with both a high-fidelity and a high-volume sound output. • Compatible with the System Sensor synchronization protocol. • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products. • Designed with a tamper-resistant construction. • Built with an updated modern design. Wall Speaker Strobe GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118page 2 of 3 www.gamewell-fci.com 9021-60931 Rev. A UL Current Draw Data Table 1 lists the UL maximum strobe current draw. Table 2 lists the speaker strobe sound outputs. Table 3 lists the speaker sound outputs. L-Series Speaker and Speaker Strobe Specifications (Continued) Architectural/Engineering Specifications (Continued) General (Continued) Also, the L-Series speaker strobes, when used with the Sync•Circuit. Module accessory, shall be powered from anon-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync•Circuit Module, either of thefollowing may occur. • 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32° F and 120°F from a regulated DC, or full-wave rectified, unfil-tered power supply. Wall-mount speaker strobes shall include the following field-selectable candela settings: - 15 - 30 - 75 - 95 - 110 - 135 - 185 Speaker The speaker shall be an L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal VRMS. It should be listed to UL Standard 1480 and shall be approved for fire protective service. Thespeaker shall have a frequency range of 400 to 4,000 Hzand shall have an operating temperature between 32°Fand 120°F. The speaker shall have power taps and voltagethat are selected by rotary switches. Speaker Strobe Combination The speaker strobe shall be an L-Series model__________ listed to UL Standard 1480 and UL Standard1971 and be approved for fire protective signaling sys- tems. The speaker shall be capable of operating at 25.0 or70.7 nominal VRMS selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speakershall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements forvisible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe lightshall consist of a xenon flash tube and associated lens/ reflector system. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed toUL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobesat 1 Hz. The module shall mount to a 4 11/16 x 4 11/16 x21/8-inch backbox. The module shall also control two StyleY (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chainingtwo or more synchronization modules together will syn- chronize all the zones they control. The module shall notoperate on a coded power supply. Physical Specifications Operating Temperature:32°F to 120°F(0°C to 49°C) Humidity Range:10 to 93% non-condensing Dimensions, Wall-Mount: Length Width Depth SP Speaker:6.5 in, 165 mm 5 in, 127 mm 2.3 in, 58 mm With Surface Mount Backbox: 6.6 in,168 mm 5.1 in,130 mm 3.2 in,82 mm SPS Speaker/Strobe(including lens and speaker):6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Backbox:6.6 in,168 mm 5.1 in,130 mm 4.55 in,116 mm Electrical/Operating Specifications Nominal Voltage (speakers):25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage (speakers):50 VDC Strobe Flash Rate:1 flash per second Nominal Voltage (strobes):Regulated 12 VDC or Regulated 24 VDC/FWR Operating Voltage Range(includes fire alarm panelswith built-in sync):8 to 17.5 V (12 V nominal) or16 to 33 V (24 V nominal) Operating Voltage withMDL3 Sync Module:8.5 to 17.5 V (12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range:400 to 4,000 Hz Power:¼, ½, 1, 2 watts Candela 8-17.5 Volts 16-33 Volts FWRDC DC 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Table 1: UL Max. Strobe Current Draw (mA RMS) Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 Table 2: Sound Output Speaker Strobe Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 83 85 2 W 88 88 Table 3: Sound Output Speaker GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60931 Rev. A page 3 of 3 Dimensions Figure 1 shows the speaker dimensions. Figure 2 shows the speaker dimensions. Surface Mounting Figure 3 illustrates the wall-mount speaker and speaker strobes with the SBBSPRL surface mount backbox. Figure 1 Wall-Mount Speaker Figure 2 Wall-Mount Speaker Strobe Figure 3 Wall-Mount Speaker Strobe with SBBSPRL Surface Mount Backbox L-Series Ordering Information Speakers and Speaker Strobes Wall Mount Part Number Description SPWL White, Speaker only SPRL Red, Speaker only SPSWL White, Speaker Strobe SPSRL Red, Speaker Strobe SPSRL-P Plain Speaker Strobe SPSWL-P White, Plain Speaker Strobe SPSWL-ALERT White, Speaker Strobe, Amber Lens SPSWL-CLR-ALERT White Speaker Strobe Clear Lens SPSRL-SP White, Speaker Strobe, Fuego Accessories RFPW White, 7 in × 9.5 in Retrofit Plate RFP Red, 7 in × 9.5 in Retrofit Plate SBBSPW White, Surface Mount Back Box for Speakers and Speaker Strobes SBBSPR Red, Surface Mount Back Box for Speakers and Speaker Strobes TRW White, Wall Mount Trim Ring TR Red, Wall Mount Trim Ring Notes: All -P models have a plain housing (no “FIRE” marking on the cover). Agency Listings Outdoor, Selectable- Output Speaker Strobes and Dual-Voltage Evacuation Speakers SpectrAlert® Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features Plug-in design• Electrical compatibility with legacy SpectrAlert products• Shorting spring on mounting plate tests continuity before • installation Rotary switch simplifies field selection of speaker voltage (25 and • 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) Ceiling- and wall-mount application• Universal mounting plate for wall- and ceiling-mount units• Weatherproof per NEMA 4X, IP56 • Compatible with System Sensor synchronization protocol• Automatic selection of 12- or 24-volt operation at 15 and 15/75 • candela Field-selectable candela settings on wall and ceiling units• The SpectrAlert Advance series offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from −40°F to 151°F. In addition, these speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. The entire SpectrAlert Advance line, including speakers, provides a plug-in design that reduces ground faults by enabling installers to pre-wire mounting plates and dress the wires before plugging in the speakers. To enable faster installation times, a shorting spring on the mounting plate provides instant feedback to ensure that wiring is properly connected. Furthermore, rotary switches simplify the selection of voltage and power settings. Both wall and ceiling speaker strobes include field-selectable candela settings that enable installers to quickly set each device to meet application requirements. The speakers’ weatherproof plastic back boxes (shipped with product) and metal back boxes (available separately) are designed to accommodate in-and-out wiring for daisy chaining outdoor devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. The screw-hole knock-outs located on the back of the back box eliminate the need to drill holes for screw-in mounting. Both weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. Included with each back box is a screw-in NPT plug with an O-ring gasket for a water tight seal.10-08-E7320-1653:20175S0 A05-0425-005 SpectrAlert® Advance Outdoor Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between –40°F and 151°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4000 Hz and shall have an operating temperature from –40°F to 150.8°F. Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048. The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model _____ listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts. The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75, 30, 75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts. The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. Physical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Dimensions, Wall-Mount SPS Speaker Strobe 6.0˝ L × 5.0˝ W × 4.7˝ D (including lens and speaker) SP Speaker 6.0˝ L × 5.0˝ W × 2.9˝ D Dimensions, Ceiling-Mount SPS Speaker Strobe 6.8˝ Dia. × 4.7˝ D (including lens and speaker) SP Speaker 6.8˝ Dia. × 2.9˝ D Dimensions, Wall-Mount Weatherproof Back Box 6.5˝ L × 5.5˝ H × 2.9˝ D Dimensions, Ceiling-Mount Weatherproof Back Box 7.2˝ Dia. × 2.9˝ D Electrical/Operating Specifications Nominal Voltage (speakers)25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Frequency Range 400 to 4000 Hz Power ¼, ½, 1, 2 watts A05-0425-005 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant (dBA @ 10 ft.)2W 1W ½ W ¼ W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 Dimensions Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 7.19˝ 7.14˝ .97˝2.83˝ 5.48˝.97˝2.83˝ 6.45˝ 7.19˝ 7.14˝ 1.60˝2.83˝2.83˝ 5.48˝2.83˝2.83˝ 1.60˝ 6.45˝ Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe Ceiling-Mount Outdoor Speaker Ceiling-Mount Outdoor Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0425-005 • 6/09 • #2189 Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes Wall Mount White Red Description SPWK*SPRK*Outdoor Speaker (includes plastic weatherproof back box) SPSWK*†SPSRK*†Outdoor Speaker Strobe, Selectable Candela (15, 15/75, 30, 75, 95, 110, 115) (includes plastic weatherproof back box) —SPSRHK Outdoor Speaker Strobe, Selectable Candela (135,150,177,185) (Includes plastic weatherproof back box) Ceiling Mount White Red Description SPCWK —Outdoor Speaker (includes plastic outdoor back box) SPSCWK —Outdoor Speaker Strobe, Selectable Candela (15, 15/75, 30, 75, 95, 110, 115) (includes plastic weatherproof back box) SPSCWHK —Outdoor Speaker Strobe, Selectable Candela, High cd (135, 150, 177, 185) (includes plastic weatherproof back box) Accessories White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box MWBBCW —Ceiling, Metal Weatherproof Back Box Notes: * Add “-R” to model number for weatherproof replacement device (no back box included), e.g., SPWK-R. Especially for use with weatherproof outdoor flush mounting plates, WTP-SP and WTP-SPW † Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., SPSWK-P. Surface Mounting Ceiling-Mount Speaker with Plastic Weatherproof Back Box Ceiling-Mount Speaker with Metal Weatherproof Back Box Ceiling-Mount Speaker Strobe with Plastic Weatherproof Back Box Ceiling-Mount Speaker Strobe with Metal Weatherproof Back Box Wall-Mount Speaker Strobe with Plastic Weatherproof Back Box Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Wall-Mount Speaker with Plastic Weatherproof Back Box Wall-Mount Speaker with Metal Weatherproof Back Box Agency Listings Features • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Universal mounting plate for wall- and ceiling-mount units • Mounting plate shorting spring tests wiring continuity before devices are installed • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Rated from –40°F to 151°F • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products The SpectrAlert Advance series offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor horns, strobes, and horn strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from −40°F to 151°F. Like the entire SpectrAlert Advance product line, these devices include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. All horns, strobes, and horn strobes use a universal mounting plate with an onboard shorting spring that tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24- volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Outdoor Selectable- Output Horns, Strobes, and Horn Strobes SpectrAlert® Advance outdoor selectable-output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes)7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) A05-0456-002 SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB)5.7˝ L × 5.1˝ W × 2.0˝ D (145 mm L × 130 mm W × 51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions (SA-WBBC)7.1˝ diameter × 2.0˝ high (180 mm diameter × 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0456-002 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output Data UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0456-002 • 11/09 • #2255 SpectrAlert Advance Dimensions Model Description Wall Horn Strobes P2RK*†2-Wire Horn Strobe, Standard cd, Red, Outdoor P2RHK*†2-Wire Horn Strobe, High cd, Red, Outdoor P2WK*†2-Wire Horn Strobe, Standard cd, White, Outdoor P2WHK*†2-Wire Horn Strobe, High cd, White, Outdoor P4RK†4-Wire Horn Strobe, Standard cd, Red, Outdoor P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V Wall Strobes SRK*†Strobe, Standard cd, Red, Outdoor SRHK*†Strobe, High cd, Red, Outdoor SWK*†Strobe, Standard cd, White, Outdoor SWHK*†Strobe, High cd, White, Outdoor Model Description Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe, Standard cd, Red, Outdoor PC2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor PC2WK 2-Wire, Horn Strobe, Standard cd, White, Outdoor PC2WHK 2-Wire, Horn Strobe High cd, White, Outdoor PC4WK 4-Wire, Horn Strobe, Standard cd, White, Outdoor PC4WHK 4-Wire, Horn Strobe, High cd, White, Outdoor Ceiling Strobes SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCWK Strobe, Standard cd, White, Outdoor SCWHK Strobe, High cd, White, Outdoor Horns HRK Horn, Red, Outdoor SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2RK-P. † Add “-R” to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4.7˝ 5.6˝ 6.8˝Dia. 2.5˝ 2.5˝ Wall-mount horn strobes Ceiling-mount horn strobes 2.23˝5.05˝ 5.98˝ 7.1˝Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝Dia. 2.0˝ Wall weatherproof back box Ceiling weatherproof back box GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 HPFF8 NAC Expander/Power SupplyDescription The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp-hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi- pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End-of-Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field-programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper-Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- ing device signal inputs (for FACP trouble notification)- Earth ground faults by individual status LED's • Separate Trouble and AC Fail Form-C relay Contacts HPFF8 An ISO 9001-2000 Company 7315-1637:0102 SIGNALING S24562 FM APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189021-60521 Rev. B page 2 of 2 www.gamewell-fci.com Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi-pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-D4 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power:120VAC/60Hz, 3.6A or 220VAC/50Hz, 1.5A Secondary Power:24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity:Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet:Up to two 18AH batteries SBB-D4 Cabinet:Up to two 12AH batteries per supply Total Output Power:8.0A max Standby Current: 0.030 A Auxiliary Power Output:0.15A under all conditions 2.0A if load is removed dur-ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings:24VDC fully regulated, 3.0A max per circuit (8.0A total) End-of-Line Resistor Range: 2K to 25k ohm, ½ watt Common Trouble Relay/AC Fail Relay:2.0A at 28VDC or 120VAC Input Control Circuit:16-30VDC @ 5mA min. Temperature Rating:32°F to 120°F (0°C to 49°C Relative Humidity:10% to 93% non-condensing Cabinet Dimensions: HPFF8 Cabinet:16.65” W x 19.0” H x 5.2” D (42.29 W x 48.26 H 13.23 D cm) SBB-D4 Cabinet:24” W x 45.9” H x 5.15” D (60.96 W x 116.52 H x 13.1D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the SBB-D4 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black 0.669 A 0.864 A Qty Draw Standby Qty Draw Alarm 1 x 0.08100 0.08100 1 x 0.15000 0.15000 1 x 0.08100 0.08100 1 x 0.15000 0.15000 Intel. Loop Interface Main Board - Apollo (ILI95-MB-E3)0 x 0.05000 0 x 0.09100 Intel. Loop Interface Supplement Board - Apollo (ILI95-S-E3)0 x 0.05000 0 x 0.09100 E3 Panel, 1 SLC 0 x 0.05600 0 x 0.07600 E3 Panel, 1 SLC with DACT 0 x 0.07500 0 x 0.09500 1 x 0.06500 0.06500 1 x 0.08500 0.08500 0 x 0.08500 0 x 0.10500 120V Power Supply Sub-Assembly (PM-9)1 x 0.05000 0.05000 1 x 0.05000 0.05000 240V Power Supply Sub-Assembly (PM-9G)0 x 0.02700 0 x 0.05000 1 x 0.02400 0.02400 1 x 0.02800 0.02800 2 x 0.01300 0.02600 0 x 0.01300 0 x 0.01800 0 x 0.01800 0 x 0.05000 0 x 0.07500 0 x 0.20000 0 x 0.20000 1 x 0.01100 0.01100 1 x 0.01100 0.01100 0 x 0.01100 0 x 0.01100 0 x 0.06500 0 x 0.06500 Intelligent Network Inferface Module (INI-7100)0 x 0.04000 0 x 0.04000 0 x 0.02000 0 x 0.020000x0.03500 0 x 0.20000 0 x 0.00100 0 x 0.001000x0.00100 0 x 0.00100 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 0 x 0.00100 0 x 0.00100 0 x 0.02000 0 x 0.020000x0.00200 0 x 0.00650 2 x 0.15000 0.30000 2 x 0.15000 0.300000x0.05000 0 x 0.05000240V Power Supply Sub-Assembly (PM-9G)1 x 0.02700 0.02700 1 x 0.05000 0.05000 0 x 0.08600 0 x 2.20600 Amplifier Sub-assembly, 50 watt 70V (AM-50-70)0 x 0.04900 0 x 2.30000 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 1 x 0.00100 0.00100 1 x 0.00100 0.00100 0 x 0.02000 0 x 0.02000 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 6 x 0.00020 0.00120 6 x 0.00200 0.01200 0 x 0.00020 0 x 0.00200 0 x 0.00020 0 x 0.00200 4 x 0.00038 0.00150 4 x 0.00500 0.02000 0 x 0.00038 0 x 0.00650 1 x 0.00030 0.00030 1 x 0.00700 0.00700 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1 1 Device AMM-4F/AMM-2F AOM-2RF/AOM-2SF MS-7AF 8. Notification Appliances Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) ASD-PL3 7. Smoke Detectors/Modules ATD-RL3 DNR Firefighter's Telephone (Handset) Addressable Output Module-Signal (AOM-2SF) Intel. Network Voice Gateway (INI-VGX) 120V Power Supply Sub-Assembly (PM-9) Class A Option Module (CAOM)Municipal Circuit Option Module (MCOM) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) Voice Paging Microphone (Microphone) Firefighter's Telephone (Handset) 3. 7100 Optional Modules Intel. Network Command Voice Gateway (INI-VGE) Addressable Switch Sub-assembly (ASM-16) Voice Paging Microphone (Microphone) Network LCD Annunicator (NGA) Auxiliary Switch Sub-Assembly (ASM-16) 4. INI-VGC Command Center Intel. Network Command Center (INI-VGC) 6. INI-VGE Command Center Voice Gateway Addressable Switch Sub-assembly (ASM-16) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Signal (AOM-2SF) 1. System Device E3 Panel, 2 SLC Amplifier Sub-assembly, 50 watt 25V (AM-50) 5. INI-VGX Voice Gateway LCD Display & Switch Control (LCD-E3) ARCNET Repeater (RPT-E3) Printer Transient Module (PTRM) Remote LED Driver Module (LDM-7100) Optional Remote Serial Annunicator (LCD-7100) Alarm CurrentStandby Current System Current Draw - FACP E3 Series Control Panel with Broadband Total AlarmTotal Standby Intel. Loop Interface, Main Board (ILI-MB-E3) Intel. Loop Interface Supplement Board (ILI-S-E3) Total Standby Load:0.669 A 0.864 ATotal Alarm Load: E3 Panel, 2 SLC with DACT 2. E3 Optional Modules Remote LED Driver Module (ANU-48) Addressable Node Expander (ANX) Digital Communicator (DACT-E3) Protected Premises:Date:8.31.2020 Address: City:State:ID Zip:83460 Prepared By:Phone:801-468-8300 Address:Email: City:State:Utah Zip:84115 Secondary Load Requirements 19.35 Amp Hours Total (AH) 16.06 0.07 16.13 x 1.20 19.35 AH 26.00 Amp Hours Battery Distribution Chart Spare Battery Capacity 6.65 Amp Hours Secondary Standby Load 19.27 Amp Hours Secondary Alarm Load 0.09 Amp Hours Current Draw Time (hours) Total Secondary Load from the calculation table below. Shows amp-hour distribution of your selections. Derating factor Secondary Load Requirements 26 AH Battery (12 volt) Required Alarm Time (hours) 0.084 hours Salt Lake City 24 hours Required Standby Time Spori Annex Building - BYU-Idaho 525 South Center Street Rexburg Nelson Fire Systems System Power Requirements E3 Fire Alarm Control Panel with Broadband Battery Selection Secondary Standby Load 0.669 A Secondary Alarm Load 1481 S Major Street office@nelsonfire.com 0.864 A x x Select batteries from the list below. Total Secondary Load Spare Battery Capacity26% Secondary Standby Load 74% Secondary Alarm Load 0%Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Standby 0.075 A Alarm 2.962 A Qty Draw Non-Alarm Qty Draw Alarm 1 x 0.07500 0.07500 1 x 0.20600 0.20600 4 x 0.00000 0.00000 4 x 0.05400 0.21600 5 x 0.00000 0.00000 5 x 0.07100 0.35500 1 x 0.00000 0.00000 1 x 0.13700 0.13700 0 x 0.00000 0 x 0.18500 2 x 0.00000 0.00000 2 x 0.06600 0.13200 1 x 0.00000 0.00000 1 x 0.09400 0.09400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.93400 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.07100 0 x 0.00000 0 x 0.13700 0 x 0.00000 0 x 0.18500 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 1 x 0.00000 0.00000 1 x 0.05400 0.05400 0 x 0.00000 0 x 0.07100 8 x 0.00000 0.00000 8 x 0.13700 1.09600 0 x 0.00000 0 x 0.18500 2 x 0.00000 0.00000 2 x 0.06600 0.13200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 1.28200 0 x 0.00000 0 x 0.05400 0 x 0.00000 0 x 0.07100 0 x 0.00000 0 x 0.13700 0 x 0.00000 0 x 0.18500 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.03000 0 x 0.03700 0 x 0.00850 0 x 0.02000 0 x 0.04000 0 x 0.05000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 1 x 0.00000 0.00000 1 x 0.54000 0.54000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000Other compatible devices 7. Compatible Devices not listed 0.075 6. Auxiliary Power PR-3 FIRERAY5000 CO1224TR E3SMRCO/E3SA Auxiliary Device Total Alarm Load: 3. L2 PC2WL15 TB4 Totals (Max 2 Amps): SPSCWL115 SPSRK15 PC2WL15 SPSCWL30 SPSCWL75 NAC #4 Totals (Max 3 Amps): P2WL15 (HS-1) Other compatible devices Total Non-Alarm Load: SPSCWL115 2. . SPSRK30 NAC #1 Totals (Max 3 Amps): Secondary Alarm CurrentSecondary Non-Alarm Current 1. System Modules 1. L1 SPSRK15 HPFF8 Main Circuit Board 2.962 System Current Draw - HPFF8 Total Current SPSCWL115 SPSCWL30 NAC #2 Totals (Max 3 Amps): Device PC2WL15 SPSCWL75 NAC #3 Totals (Max 3 Amps): SPSCWL115 4. . PC2WL15 SPSCWL30 SPSCWL75 SPSCWL30 SPSCWL75 Protected Premises:Date:8.31.2020 Address: City:State:ID Zip:83460 Prepared By:Phone:801.468.8300 Address:Email: City:State:UT Zip:84115 Secondary Load Requirements 3.05 Amp Hours Total (AH) 1.80 0.74 2.54 x 1.2 3.05 AH 8 Amp Hours TRUE 1481 S Major Street Office@nelsonfire.com Salt Lake City Secondary Power Requirements Spori Annex Building - BYU-Idaho 525 South Center Street Rexburg Nelson Fire Systems HPFF8 Power Supply Time (hours) Required Standby Time 24 hoursx Total Secondary Load from the calculation table below. 0.075 A Secondary Load Requirements Total Secondary Load Secondary Alarm Load x2.962 A Required Alarm Time (hours) 0.250 hours Current Draw Secondary Standby Load Select batteries from the list below. Battery Selection 8.0 AH BAT-1270 Battery (12 volt) Derating factor Page 2 of 131 Battery Distribution Chart Comments 4.95 2.16 0.89 Secondary Alarm Load (AH) * Derating FactorSecondary Alarm Load Shows amp-hour distribution of your selections. 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Spare Battery Capacity Secondary Standby Load 2. Selected battery size meets secondary load requirements. Battery Selection (AH) - Secondary Load Requirements (AH) Secondary Standby Load (AH) * Derating Factor 1. Batteries will fit in the FACP cabinet. Spare Battery Capacity 62% Secondary Standby Load 27% Secondary Alarm Load 11% Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Page 3 of 131 Honeywell Online Tools For Fire Version 2.0.14 PROJECT DETAILS Project Name : Spori Annex Building - BYU-Idaho Project Code : Project Location : 525 South Center Street, ID, Utah, 83460 PREPARED BY Nelson Fire Systems 1481 S Major St, Salt Lake City, Utah, 84115 Voltage Drop Calculations POWER SOURCE : FF8 MODEL NUMBER : HPFF8 BRAND : HPP CLASS B 20.4 VOLTS DC POWER CIRCUIT: L1 3 Amps 14 AWG 13 DEVICES 27.07 % (0.812) AMPS USED 3.96 % (0.808) VOLTAGE DROP POWER SOURCE : FF8 MODEL NUMBER : HPFF8 BRAND : HPP CLASS B 20.4 VOLTS DC POWER CIRCUIT: L2 3 Amps 14 AWG 11 DEVICES 34.37 % (1.031) AMPS USED 14.86 % (3.031) VOLTAGE DROP #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 SPSWL 75 0.107 300 19.157 18.427 17.258 15.402 2 SPSRK (Strobe)15 0.066 55 18.953 18.103 16.742 14.581 3 SPSWL 75 0.107 25 18.867 17.966 16.524 14.234 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG 1 SPSWL 75 0.107 20 20.335 20.296 20.235 20.138 2 SPSWL 30 0.063 20 20.278 20.206 20.092 19.910 3 SPSWL 30 0.063 30 20.201 20.083 19.896 19.599 4 SPSWL 30 0.063 20 20.154 20.009 19.778 19.412 5 SPSWL 15 0.043 25 20.102 19.927 19.647 19.204 6 SPSWL 30 0.063 20 20.064 19.867 19.551 19.051 7 SPSWL 30 0.063 35 20.006 19.775 19.405 18.819 8 SPSRK (Strobe)15 0.066 20 19.978 19.731 19.334 18.707 9 SPSWK (Strobe)15 0.066 20 19.955 19.695 19.277 18.616 10 SPSWL 30 0.063 40 19.920 19.640 19.190 18.477 11 SPSWL 15 0.043 20 19.908 19.621 19.159 18.428 12 SPSWL 15 0.043 20 19.899 19.607 19.137 18.393 13 SPSWK (Strobe)15 0.066 35 19.890 19.592 19.114 18.356 Voltage Drop 0.510 0.808 1.286 2.044 Page: 1 08/31/2020 15:07:47 PM 4 SPSWL 75 0.107 20 18.807 17.870 16.371 13.991 5 SPSWL 75 0.107 30 18.729 17.747 16.175 13.679 6 SPSWL 15 0.043 25 18.675 17.661 16.039 13.462 7 SPSWL 75 0.107 20 18.635 17.598 15.939 13.302 8 SPSWL 75 0.107 30 18.588 17.524 15.821 13.114 9 SPSRK (Strobe)15 0.066 60 18.520 17.417 15.650 12.843 10 SPSWL 75 0.107 25 18.498 17.383 15.596 12.757 11 SPSWL 75 0.107 20 18.489 17.369 15.574 12.722 Voltage Drop 1.911 3.031 4.826 7.678 #MODEL CANDELA PATTERN VOLUME TONE CURRENT (amps) DISTANCE FROM PREVIOUS DEVICE (Ft) 12 AWG 14 AWG 16 AWG 18 AWG Page: 2 08/31/2020 15:07:47 PM SPORI ANNEX BUILDING BRIGHAM YOUNG UNIVERSITY- IDAHO FIRE ALARM SYSTEM JPK PAYNE TDT (ANSI B) 1/16" = 1' XXXX XXXX SP O R I A N N E X B U I L D I N G BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 6 0 FI R E A L A R M S Y S T E M PROJECT COVER SHEET FA-C-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: INDEX OF DRAWINGS PAGE 1 2 3 4 5 FA-C-01 FA-R-01 FA-1-01 FA-1-02 FA-1-03 SHEET #LEVEL PROJECT COVER SHEET / INDEX OF DRAWINGS FIRE ALARM BUILDING RISER DIAGRAM / MATRIX BUILDING BUILDING BUILDING DEVICE SCHEDULE COUNTS SMOKE DETECTOR w/BASE MANUAL PULL STATION MONITOR MODULE SPEAKER/STROBE- WALL MULTI-VOLTAGE RELAY ASD-PL3 w/B300-6 MS-7AF AMM-4F SPSWL PR-3 DESCRIPTION LOCAL OPERATING CONSOLE INCC-CAB FIRE ALARM CONTROL UNIT E3-BB-BC/INCC FIRE/SMOKE DAMPER PROVIDED BY OTHERS S F MM SS R FACU FSD 4 SQ. 2-1/8" DEEP BOX MINIMUM w/3/O MUD RING 4 SQ. 2-1/8" DEEP BOX MINIMUM w/SINGLE GANG MUD RING 4 SQ. 2-1/8" DEEP BOX MINIMUM 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2" EXT. RING 4 SQ. 2-1/8" DEEP BOX MINIMUM SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. PROVIDED BY OTHERS PART NUMBER MOUNTING REQUIREMENTSYMBOL 6 1 4 5 1 19 5 5 1 1 WEATHERPROOF SPEAKER/STROBE- WALL SPSRKSSWP SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. SHEET CONTENTS ADDRESSABLE CIRCUITS NOTIFICATION CIRCUITS ADDRESSABLE NUMBERS LOC WEATHERPROOF HORN/STROBE- WALL P2RKHSWP SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS. SPORTI ANNEX COVER.DWG 8/21/2020 1:50:41 PM NAC PANEL SBB-C4NAC SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS.1 1 PAIR #14'S TWISTED ADDRESSABLE CIRCUIT N1L1S001 N1L1S002 N1L1S003 N1L1M001 N1L1M005 N1L1M006 N1L1M007 N1L1M008 N1L1S004 N1L1S005 INSTALL (2) STRANDS FIBER OPTIC SINGLE MODE FIBER WITH LC CONNECTORS (OPTIMIZED FOR 9 125 MICROMETER CABLE @1310 NM. UP TO 30 dB LOSS BETWEEN NODES) TO FACILITATE CONNECTION OF BUILDING CONTROL PANEL TO FIRE/EMERGENCY VOICE ALARM NETWORK. OUTGOING AND RETURN CIRCUITS SHALL BE PHYSICALLY SEPARATED AND INSTALLED IN SEPARATED CONDUIT/RACEWAY. 1 2 STRANDS SINGLE MODE FIBER OPTIC PER SYSTEM MANUFACTURER 2" CONDUIT WITH LONG RADIUS ELBOWS FIRE ALARM NETWORK CONNECTION TYPICAL ALL LOCATIONS 1 FIBER INTERCONNECT CONDUIT 2 STRANDS SINGLE MODE FIBER OPTIC PER SYSTEM MANUFACTURER 2" CONDUIT WITH LONG RADIUS ELBOWS FIRE ALARM NETWORK CONNECTION TYPICAL ALL LOCATIONS 1 FIBER INTERCONNECT CONDUIT SPORI ANNEX BUILDING DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUIT JPK PAYNE TDT (ANSI B) 1/16" = 1' XXXX XXXX SP O R I A N N E X B U I L D I N G BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O FI R E A L A R M R I S E R D I A G R A M / M A T R I X 52 5 S C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 6 0 FI R E A L A R M S Y S T E M FIRE RISER DIAGRAM / MATRIX FA-R-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: BUILDING- SMOKE DETECTORS BUILDING- PULL STATIONS BUILDING- TAMPER SWITCH BUILDING- WATERFLOW SWITCH LOSS OF POWER ANY PANEL OR NAC LOW BATTERY CONDITIONS OPEN CIRCUIT CONDITIONS GROUND FAULTS FACPANNUNCIATION NOTIFICATION FIRESAFETY CONTROL REPORTING SYSTEM INPUTS SYSTEM OUTPUTSFIRE ALARM INPUT/OUTPUT MATRIX AL A R M S I G N A L T O F I R E A L A R M D I S P L A Y SU P E R V I S O R Y S I G N A L T O F I R E A L A R M D I S P L A Y TR O U B L E S I G N A L T O F I R E A L A R M D I S P L A Y BU I L D I N G S P E A K E R / S T R O B E S FIR E / S M O K E D A M P E R S AL A R M S I G N A L T O M O N I T O R I N G C O M P A N Y SU P E R V I S O R Y S I G N A L T O M O N I T O R I N G C O M P A N Y TR O U B L E S I G N A L T O M O N I T O R I N G C O M P A N Y SPORI ANNEX RISER.DWG 8/21/2020 1:50:41 PM MANUAL PULL STATION (MS-7AF) ADDRESSABLE CKT 1 2 3 4 FIRE PUSH INPULL DOWN IN(+) (-)TO NEXT DEVICEOUT(+) (-)FIRE 80" FLOOR LINE 96" 48" 60" MOUNTING HEIGHTS PULL STATIONTOP AT 48" WALL NOTIFICATION DEVICE MAXIMUM 96" TO TOPMINIMUM 80" TO BOTTOM FACU TOP AT 72" REMOTE ANNUNCIATOR TOP AT 60" 72" ADDRESSABLE DETECTOR BASE 3 2(+)1(-) (+) (-) FR O M N A C P A N E L (+) (-) B300 AD D R E S S A B L E C K T OR P R E V I O U S D E V I C E TO N E X T D E V I C E SPRINKLER NOTIFICATION MODULES NO NCCOM NONCCOM NOTIFICATION MODULESPRINKLERAMM-4F WATERFLOW ALARMAMM-4F 47K Ω SPRINKLER WATERFLOW SWITCH 47K Ω CI R C U I T O U T AD D R E S S A B L E (-) (+) (+) (-) CIR C U I T I N AD D R E S S A B L E SPSRK - WEATHERPROOF SPEAKER STROBE TO NEXT DEVICESPEAKER CKT OUTIN TO NEXT DEVICE(+)(-)STROBE CIRCUIT IN OUT(+)(-) SPSWL - WALL SPEAKER STROBE TO NEXT DEVICESPEAKER CKT OUTIN TO NEXT DEVICE(+)(-)STROBE CIRCUITIN OUT(+)(-) 1/2WSP1-11/2WSP1-21/2WSP1-31/2WSP1-41/2WSP1-51/2WSP1-61/2WSP1-71/2WSP1-81/2WSP1-91/2WSP1-101/2WSP1-11 1 PAIR #14'S TWISTED SHIELDED SPEAKER CIRCUIT L1-175cdL1-230cdL1-330cdL1-430cdL1-515cdL1-630cdL1-730cdL1-815cdL1-915cdL1-1030cdL1-1115cd 1/2WSP1-221/2WSP1-211/2WSP1-201/2WSP1-191/2WSP1-181/2WSP1-171/2WSP1-161/2WSP1-151/2WSP1-14 L2-915cdL2-875cdL2-775cdL2-615cdL2-575cdL2-475cdL2-375cdL2-215cdL2-175cd 4 #14'S (2) STROBE CIRCUITS E.O.L. 3.9K E.O.L. 3.9KE.O.L. 4.7K 1/2WSP1-23 L2-1075cd 1/2WSP1-12 L1-1215cd 1/2WSP1-13 L1-1315cd 1/2WSP1-24 L2-1175cd FSD 4 #14'S 4 #14'S 4 #14'S 2 #14'S 2 #14'S RELAY CIRCUIT 3 #12'S FSD 3 #12'S FSD 3 #12'S FSD 3 #12'S FSD 3 #12'S 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 3 #12'S 120 VAC 3 #12'S 120 VAC 3 #12'S 120 VAC 3 #12'S 120 VAC 3 #12'S 120 VAC INCC-CAB LOCAL OPERATING CONSOLE 4.5" DEEP19.375" WIDE 19.375" HIGH 2 PAIR #16'S TWISTED 2 PAIR #16'S TWISTED/SHIELDED 2 PAIR #16'S TWISTED 2 PAIR #16'S TWISTED/SHIELDED LOCATED IN FOYER 1B HS1-1 L3-115cd 2 #14'S WATER BELL CIRCUIT 2 TO NEXT BUILDING 2 DEVICE LEGEND S SMOKE DETECTOR F PULL STATION TS TAMPER SWITCH WF WATERFLOW SWITCH SN SIGNAL MODULE SS SPEAKER/STROBE- WALL R RELAY LOCAL OPERATING CONSOLE FACU FIRE ALARM CONTROL UNIT NAC NAC DESCRIPTIONCOUNTS HS WEATHER PROOF HORN/STROBE SYMBOL 61 2 1 15 1 19 5 11 1 FSD FIRE/SMOKE DAMPER5 WP SS WEATHERPROOF SPEAKER/STROBEWP LOC FACU E3-BB-BC/ ASM-16LCD-SLP(2)FSL-E3(2)RPT-E3 PM-9 4.5" DEEP19.375" WIDE 30" HIGH LOCATED IN DATA ROOM 119C DEDICATED CIRCUIT 120 VAC W/GROUND INCC 2 CAT-6E TO NETWORK PORTS N1L1S006 E.O.L. 3.9K E.O.L. 3.9K (1) HP-FF8 5.2" DEEP24" WIDE37.13" HIGH TRANSPONDER SBB-C4w/FCI-DR-C4B ILI-MB-E3 AM-50INI-VGXINCC-MIC LCD-SLP CONDUITS& ONE 3/4"TWO 1" 4" DEEP 17" WIDE8" HIGH MINI BATTERY CABINET MMO-6SF WEATHERPROOF WATERFLOW HORN/STROBE (P2RK) (+) (-) FROM NAC PANEL IN (+)(-)OUT STROBE CIRCUIT JPK PAYNE TDT (ANSI B) 1/16" = 1' XXXX XXXX SP O R I A N N E X B U I L D I N G BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 6 0 FI R E A L A R M S Y S T E M SPORI ANNEX ADDRESSABLE FA-1-01 SYSTEM NOTES: TO NAC PANEL LOCATED IN DATA ROOM 119C NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 25'10'50' W E S N 1 SN 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: 8/28/2020 8:43:28 AM SPORI ANNEX.DWG DEVICE LEGEND S SMOKE DETECTOR F PULL STATION TS TAMPER SWITCH WF WATERFLOW SWITCH SN SIGNAL MODULE SS SPEAKER/STROBE- WALL R RELAY LOCAL OPERATING CONSOLE FACU FIRE ALARM CONTROL UNIT NAC NAC PANEL DESCRIPTIONCOUNTS HS WEATHER PROOF HORN/STROBE SYMBOL 6 1 2 1 1 5 1 1 1 FSD FIRE/SMOKE DAMPER5 WP SS WEATHERPROOF SPEAKER/STROBEWP LOC WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED B C RELAY CIRCUIT 2 #14'S D 120 VAC POWER 3 #12'S E SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED LOCAL OPERATING CONSOLE 2 PAIR #16'S TWISTED 2 PAIR #16'S TWISTED/SHIELDED F STROBE CIRCUIT 2 #14'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS G WATER BELL CIRCUIT 2 #14'S OFFICE 100 VESTIBULE 1-A FOYER 1-B OFFICE 105 VESTIBULE 1-C CERAMICS CLASSROOM 104 WOMEN'S RESTROOM 103 MEN'S RESTROOM 102 MECHANICAL & ELECTRICAL ROOM 119B CUSTODIAL 119A DATA ROOM 119C SCULPTURE CLASSROOM 101 WOOD SHOP 110 KILN ROOM 112 HALLWAY 1-E B.F.A. STUDIO 113 TOOL ROOM 114 HALLWAY 1-F GLAZING ROOM 118 DAMP ROOM 104A CLAY STORAGE 117A RAKU KILN AREA 115 CLAY MIXING & DRY STORAGE 117 FOUNDRY, FORGE & WELDING AREA 111 HALLWAY 1-D PLASTER AREA 101B FURNITURE STORAGE AREA 101A MECHANICAL RISER ROOM 116 FSD FSD FSD FSD FSD F A C U F WF TS TS S R R R R R 1 B 2 C CC C C C 2 C 2 C 2 C 2 C LOC 1 F 1 F S S S S S N A C 1 A 120 VAC TO RELAY FOR FIRE SMOKE DAMPER2 E.O.L. 3.9K SEE RISER FA-R-01 FOR WATER FLOW INTERCONNECT3 3 JPK PAYNE TDT (ANSI B) 1/16" = 1' XXXX XXXX SP O R I A N N E X B U I L D I N G BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 6 0 FI R E A L A R M S Y S T E M SPORI ANNEX NOTIFICATION FA-1-02 SYSTEM NOTES: TO NAC PANEL LOCATED IN DATA ROOM 119C NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 25'10'50' W E S N 1 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: 8/28/2020 8:43:28 AM SPORI ANNEX.DWG DEVICE LEGEND S SMOKE DETECTOR F PULL STATION TS TAMPER SWITCH WF WATERFLOW SWITCH SN SIGNAL MODULE SS SPEAKER/STROBE- WALL R RELAY LOCAL OPERATING CONSOLE FACU FIRE ALARM CONTROL UNIT NAC NAC PANEL DESCRIPTIONCOUNTS HS WEATHER PROOF HORN/STROBE SYMBOL 1 19 5 1 1 1 FSD FIRE/SMOKE DAMPER WP SS WEATHERPROOF SPEAKER/STROBEWP LOC WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED B C RELAY CIRCUIT 2 #14'S D 120 VAC POWER 3 #12'S E SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED LOCAL OPERATING CONSOLE 2 PAIR #16'S TWISTED 2 PAIR #16'S TWISTED/SHIELDED F STROBE CIRCUIT 2 #14'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS G WATER BELL CIRCUIT 2 #14'S OFFICE 100 VESTIBULE 1-A FOYER 1-B OFFICE 105 VESTIBULE 1-C CERAMICS CLASSROOM 104 WOMEN'S RESTROOM 103 MEN'S RESTROOM 102 MECHANICAL & ELECTRICAL ROOM 119B CUSTODIAL 119A DATA ROOM 119C SCULPTURE CLASSROOM 101 WOOD SHOP 110 KILN ROOM 112 HALLWAY 1-E B.F.A. STUDIO 113 TOOL ROOM 114 HALLWAY 1-F GLAZING ROOM 118 DAMP ROOM 104A CLAY STORAGE 117A RAKU KILN AREA 115 CLAY MIXING & DRY STORAGE 117 FOUNDRY, FORGE & WELDING AREA 111 HALLWAY 1-D PLASTER AREA 101B FURNITURE STORAGE AREA 101A MECHANICAL RISER ROOM 116 F A C U SS SS SS SS SS SS SS SSSS SS SS SSSS SS SS SS SS WPSSWP SSWP SS WP SS WP SP1-11/2WL1-175cd SP1-21/2WL1-230cd SP1-31/2WL1-330cd SP1-41/2WL1-430cd SP1-51/2WL1-515cd SP1-61/2WL1-630cd SP1-81/2WL1-815cd SP1-91/2WL1-915cd SP1-101/2WL1-1030cd SP1-121/2WL1-1215cd SP1-111/2WL1-1115cd SP1-131/2WL1-1315cd SP1-151/2WL2-215cdSP1-161/2WL2-375cd SP1-171/2WL2-475cd SP1-181/2WL2-575cd SP1-191/2WL2-615cd SP1-201/2WL2-775cd SP1-241/2WL2-1175cd SP1-231/2WL2-1075cd SP1-221/2WL2-915cd 1 D,(2)E E.O.L. 3.9K E.O.L. 3.9KE.O.L. 4.7K LOC SS SS SP1-141/2WL2-175cd SS SP1-71/2WL1-730cd SP1-211/2WL2-875cd HS WP 1 G HS1-115cd N A C 120 VAC TO RELAY FOR FIRE SMOKE DAMPER2 SEE RISER FA-R-01 FOR WATER FLOW INTERCONNECT3 JPK PAYNE TDT (ANSI B) 1/16" = 1' XXXX XXXX SP O R I A N N E X B U I L D I N G BR I G H A M Y O U N G U N I V E R S I T Y - I D A H O 52 5 S C E N T E R S T R E E T RE X B U R G , I D A H O 8 3 4 6 0 FI R E A L A R M S Y S T E M SPORI ANNEX NUMBERS FA-1-03 SYSTEM NOTES: TO NAC PANEL LOCATED IN DATA ROOM 119C NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 25'10'50' W E S N 1 SN 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: 8/28/2020 8:43:28 AM SPORI ANNEX.DWG DEVICE LEGEND S SMOKE DETECTOR F PULL STATION TS TAMPER SWITCH WF WATERFLOW SWITCH SN SIGNAL MODULE SS SPEAKER/STROBE- WALL R RELAY LOCAL OPERATING CONSOLE FACU FIRE ALARM CONTROL UNIT NAC NAC PANEL DESCRIPTIONCOUNTS HS WEATHER PROOF HORN/STROBE SYMBOL 6 1 2 1 1 1 1 1 FSD FIRE/SMOKE DAMPER WP SS WEATHERPROOF SPEAKER/STROBEWP LOC WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED B C RELAY CIRCUIT 2 #14'S D 120 VAC POWER 3 #12'S E SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED LOCAL OPERATING CONSOLE 2 PAIR #16'S TWISTED 2 PAIR #16'S TWISTED/SHIELDED F STROBE CIRCUIT 2 #14'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS G WATER BELL CIRCUIT 2 #14'S OFFICE 100 VESTIBULE 1-A FOYER 1-B OFFICE 105 VESTIBULE 1-C CERAMICS CLASSROOM 104 WOMEN'S RESTROOM 103 MEN'S RESTROOM 102 MECHANICAL & ELECTRICAL ROOM 119B CUSTODIAL 119A DATA ROOM 119C SCULPTURE CLASSROOM 101 WOOD SHOP 110 KILN ROOM 112 HALLWAY 1-E B.F.A. STUDIO 113 TOOL ROOM 114 HALLWAY 1-F GLAZING ROOM 118 DAMP ROOM 104A CLAY STORAGE 117A RAKU KILN AREA 115 CLAY MIXING & DRY STORAGE 117 FOUNDRY, FORGE & WELDING AREA 111 HALLWAY 1-D PLASTER AREA 101B FURNITURE STORAGE AREA 101A MECHANICAL RISER ROOM 116 F A C U F WF TS TS S LOC S S S S L1S001 N1 L1S002 N1 L1S003N1 L1S004N1 L1S005N1 L1M001 N1 N1-L1M005N1-L1M006N1-L1M007 N1-L1M008 S L1S006 N1 N A C 120 VAC TO RELAY FOR FIRE SMOKE DAMPER2 SEE RISER FA-R-01 FOR WATER FLOW INTERCONNECT3