PROJECT COVER SHEET
FA-C-01
NELSON FIRE SYSTEMS
DRAWN BY:
DESIGNED BY:
APPROVED BY:
DATE:
SCALE:
PROJECT NO:
REVISION NO:
DRAWING NAME:
NO
T
E
:
NF
S
D
R
A
W
I
N
G
S
A
R
E
B
A
S
E
D
O
N
T
H
E
P
R
O
J
E
C
T
AR
C
H
I
T
E
C
T
U
R
E
/
E
N
G
I
N
E
E
R
(
A
/
E
)
P
L
A
N
S
A
N
D
SP
E
C
I
F
I
C
A
T
I
O
N
S
F
U
R
N
I
S
H
E
D
T
O
N
F
S
.
A
/
E
I
S
S
O
L
E
L
Y
RE
S
P
O
N
S
I
B
L
E
(
N
O
T
N
F
S
)
F
O
R
T
H
E
T
Y
P
E
,
S
I
Z
E
,
LO
C
A
T
I
O
N
,
A
N
D
S
U
I
T
A
B
I
L
I
T
Y
O
F
A
L
L
F
I
R
E
A
L
A
R
M
S
,
CO
N
T
R
O
L
P
A
N
E
L
S
,
A
N
D
O
T
H
E
R
D
E
V
I
C
E
S
S
H
O
W
N
O
N
TH
E
A
/
E
P
L
A
N
S
.
N
F
S
D
R
A
W
I
N
G
S
A
R
E
T
O
S
H
O
W
O
N
L
Y
TH
E
W
I
R
I
N
G
D
I
A
G
R
A
M
S
B
E
T
W
E
E
N
F
I
R
E
A
L
A
R
M
DE
V
I
C
E
S
A
N
D
C
O
N
T
R
O
L
P
A
N
E
L
S
.
N
F
S
I
S
N
O
T
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
I
N
F
O
R
M
A
T
I
O
N
S
H
O
W
N
O
N
T
H
E
A/
E
P
L
A
N
S
.
NELSON FIRE SYSTEMS
PAGE:
INDEX OF DRAWINGS
PAGE
1
2
3
4
5
FA-C-01
FA-R-01
FA-1-01
FA-1-02
FA-1-03
SHEET #LEVEL
PROJECT COVER SHEET / INDEX OF DRAWINGS
FIRE ALARM BUILDING RISER DIAGRAM / MATRIX
BUILDING
BUILDING
BUILDING
DEVICE SCHEDULE
COUNTS
SMOKE DETECTOR w/BASE
MANUAL PULL STATION
MONITOR MODULE
SPEAKER/STROBE- WALL
MULTI-VOLTAGE RELAY
ASD-PL3 w/B300-6
MS-7AF
AMM-4F
SPSWL
PR-3
DESCRIPTION
LOCAL OPERATING CONSOLE INCC-CAB
FIRE ALARM CONTROL UNIT E3-BB-BC/INCC
FIRE/SMOKE DAMPER PROVIDED BY OTHERS
S
F
MM
SS
R
FACU
FSD
4 SQ. 2-1/8" DEEP BOX MINIMUM w/3/O MUD RING
4 SQ. 2-1/8" DEEP BOX MINIMUM w/SINGLE GANG MUD RING
4 SQ. 2-1/8" DEEP BOX MINIMUM
4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2" EXT. RING
4 SQ. 2-1/8" DEEP BOX MINIMUM
SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS.
SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS.
PROVIDED BY OTHERS
PART NUMBER MOUNTING REQUIREMENTSYMBOL
6
1
4
5
1
19
5
5
1
1
WEATHERPROOF SPEAKER/STROBE- WALL SPSRKSSWP SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS.
SHEET CONTENTS
ADDRESSABLE CIRCUITS
NOTIFICATION CIRCUITS
ADDRESSABLE NUMBERS
LOC
WEATHERPROOF HORN/STROBE- WALL P2RKHSWP SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS.
SPORTI ANNEX COVER.DWG
8/21/2020 1:50:41 PM
NAC PANEL SBB-C4NAC SUPPLIED BY NFS. FOLLOW MANUFACTURERS INSTRUCTIONS.1
1 PAIR #14'S TWISTED
ADDRESSABLE CIRCUIT
N1L1S001 N1L1S002 N1L1S003 N1L1M001 N1L1M005 N1L1M006 N1L1M007 N1L1M008 N1L1S004 N1L1S005
INSTALL (2) STRANDS FIBER OPTIC SINGLE
MODE FIBER WITH LC CONNECTORS
(OPTIMIZED FOR 9
125 MICROMETER CABLE
@1310 NM. UP TO 30 dB LOSS BETWEEN
NODES) TO FACILITATE CONNECTION OF
BUILDING CONTROL PANEL TO
FIRE/EMERGENCY VOICE ALARM NETWORK.
OUTGOING AND RETURN CIRCUITS SHALL BE
PHYSICALLY SEPARATED AND INSTALLED IN
SEPARATED CONDUIT/RACEWAY.
1
2 STRANDS SINGLE MODE FIBER OPTIC
PER SYSTEM MANUFACTURER
2" CONDUIT WITH LONG RADIUS ELBOWS
FIRE ALARM NETWORK CONNECTION
TYPICAL ALL LOCATIONS
1 FIBER INTERCONNECT CONDUIT 2 STRANDS SINGLE MODE FIBER OPTIC
PER SYSTEM MANUFACTURER
2" CONDUIT WITH LONG RADIUS ELBOWS
FIRE ALARM NETWORK CONNECTION
TYPICAL ALL LOCATIONS
1 FIBER INTERCONNECT CONDUIT
SPORI ANNEX BUILDING
DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUIT
JPK
PAYNE
TDT
(ANSI B) 1/16" = 1'
XXXX
XXXX
SP
O
R
I
A
N
N
E
X
B
U
I
L
D
I
N
G
BR
I
G
H
A
M
Y
O
U
N
G
U
N
I
V
E
R
S
I
T
Y
-
I
D
A
H
O
FI
R
E
A
L
A
R
M
R
I
S
E
R
D
I
A
G
R
A
M
/
M
A
T
R
I
X
52
5
S
C
E
N
T
E
R
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
A
H
O
8
3
4
6
0
FI
R
E
A
L
A
R
M
S
Y
S
T
E
M
FIRE RISER DIAGRAM / MATRIX
FA-R-01
NELSON FIRE SYSTEMS
DRAWN BY:
DESIGNED BY:
APPROVED BY:
DATE:
SCALE:
PROJECT NO:
REVISION NO:
DRAWING NAME:
NO
T
E
:
NF
S
D
R
A
W
I
N
G
S
A
R
E
B
A
S
E
D
O
N
T
H
E
P
R
O
J
E
C
T
AR
C
H
I
T
E
C
T
U
R
E
/
E
N
G
I
N
E
E
R
(
A
/
E
)
P
L
A
N
S
A
N
D
SP
E
C
I
F
I
C
A
T
I
O
N
S
F
U
R
N
I
S
H
E
D
T
O
N
F
S
.
A
/
E
I
S
S
O
L
E
L
Y
RE
S
P
O
N
S
I
B
L
E
(
N
O
T
N
F
S
)
F
O
R
T
H
E
T
Y
P
E
,
S
I
Z
E
,
LO
C
A
T
I
O
N
,
A
N
D
S
U
I
T
A
B
I
L
I
T
Y
O
F
A
L
L
F
I
R
E
A
L
A
R
M
S
,
CO
N
T
R
O
L
P
A
N
E
L
S
,
A
N
D
O
T
H
E
R
D
E
V
I
C
E
S
S
H
O
W
N
O
N
TH
E
A
/
E
P
L
A
N
S
.
N
F
S
D
R
A
W
I
N
G
S
A
R
E
T
O
S
H
O
W
O
N
L
Y
TH
E
W
I
R
I
N
G
D
I
A
G
R
A
M
S
B
E
T
W
E
E
N
F
I
R
E
A
L
A
R
M
DE
V
I
C
E
S
A
N
D
C
O
N
T
R
O
L
P
A
N
E
L
S
.
N
F
S
I
S
N
O
T
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
I
N
F
O
R
M
A
T
I
O
N
S
H
O
W
N
O
N
T
H
E
A/
E
P
L
A
N
S
.
NELSON FIRE SYSTEMS
PAGE:
BUILDING- SMOKE DETECTORS
BUILDING- PULL STATIONS
BUILDING- TAMPER SWITCH
BUILDING- WATERFLOW SWITCH
LOSS OF POWER ANY PANEL OR NAC
LOW BATTERY CONDITIONS
OPEN CIRCUIT CONDITIONS
GROUND FAULTS
FACPANNUNCIATION NOTIFICATION FIRESAFETY CONTROL REPORTING
SYSTEM INPUTS
SYSTEM OUTPUTSFIRE ALARM
INPUT/OUTPUT MATRIX
AL
A
R
M
S
I
G
N
A
L
T
O
F
I
R
E
A
L
A
R
M
D
I
S
P
L
A
Y
SU
P
E
R
V
I
S
O
R
Y
S
I
G
N
A
L
T
O
F
I
R
E
A
L
A
R
M
D
I
S
P
L
A
Y
TR
O
U
B
L
E
S
I
G
N
A
L
T
O
F
I
R
E
A
L
A
R
M
D
I
S
P
L
A
Y
BU
I
L
D
I
N
G
S
P
E
A
K
E
R
/
S
T
R
O
B
E
S
FIR
E
/
S
M
O
K
E
D
A
M
P
E
R
S
AL
A
R
M
S
I
G
N
A
L
T
O
M
O
N
I
T
O
R
I
N
G
C
O
M
P
A
N
Y
SU
P
E
R
V
I
S
O
R
Y
S
I
G
N
A
L
T
O
M
O
N
I
T
O
R
I
N
G
C
O
M
P
A
N
Y
TR
O
U
B
L
E
S
I
G
N
A
L
T
O
M
O
N
I
T
O
R
I
N
G
C
O
M
P
A
N
Y
SPORI ANNEX RISER.DWG
8/21/2020 1:50:41 PM
MANUAL PULL STATION (MS-7AF)
ADDRESSABLE CKT
1 2 3 4 FIRE
PUSH INPULL DOWN
IN(+)
(-)TO NEXT DEVICEOUT(+)
(-)FIRE
80"
FLOOR LINE
96"
48"
60"
MOUNTING HEIGHTS
PULL STATIONTOP AT 48"
WALL NOTIFICATION DEVICE
MAXIMUM 96" TO TOPMINIMUM 80" TO BOTTOM
FACU
TOP AT 72"
REMOTE ANNUNCIATOR
TOP AT 60"
72"
ADDRESSABLE DETECTOR BASE
3
2(+)1(-)
(+)
(-)
FR
O
M
N
A
C
P
A
N
E
L
(+)
(-)
B300
AD
D
R
E
S
S
A
B
L
E
C
K
T
OR
P
R
E
V
I
O
U
S
D
E
V
I
C
E
TO
N
E
X
T
D
E
V
I
C
E
SPRINKLER NOTIFICATION MODULES
NO NCCOM NONCCOM
NOTIFICATION MODULESPRINKLERAMM-4F
WATERFLOW ALARMAMM-4F
47K Ω
SPRINKLER WATERFLOW SWITCH
47K Ω
CI
R
C
U
I
T
O
U
T
AD
D
R
E
S
S
A
B
L
E
(-)
(+)
(+)
(-)
CIR
C
U
I
T
I
N
AD
D
R
E
S
S
A
B
L
E
SPSRK - WEATHERPROOF SPEAKER STROBE
TO NEXT DEVICESPEAKER CKT OUTIN
TO NEXT DEVICE(+)(-)STROBE CIRCUIT IN OUT(+)(-)
SPSWL - WALL SPEAKER STROBE
TO NEXT DEVICESPEAKER CKT OUTIN
TO NEXT DEVICE(+)(-)STROBE CIRCUITIN OUT(+)(-)
1/2WSP1-11/2WSP1-21/2WSP1-31/2WSP1-41/2WSP1-51/2WSP1-61/2WSP1-71/2WSP1-81/2WSP1-91/2WSP1-101/2WSP1-11
1 PAIR #14'S TWISTED SHIELDED
SPEAKER CIRCUIT L1-175cdL1-230cdL1-330cdL1-430cdL1-515cdL1-630cdL1-730cdL1-815cdL1-915cdL1-1030cdL1-1115cd
1/2WSP1-221/2WSP1-211/2WSP1-201/2WSP1-191/2WSP1-181/2WSP1-171/2WSP1-161/2WSP1-151/2WSP1-14
L2-915cdL2-875cdL2-775cdL2-615cdL2-575cdL2-475cdL2-375cdL2-215cdL2-175cd
4 #14'S
(2) STROBE CIRCUITS
E.O.L. 3.9K
E.O.L. 3.9KE.O.L. 4.7K
1/2WSP1-23
L2-1075cd
1/2WSP1-12
L1-1215cd
1/2WSP1-13
L1-1315cd
1/2WSP1-24
L2-1175cd
FSD
4 #14'S 4 #14'S 4 #14'S 2 #14'S
2 #14'S
RELAY CIRCUIT
3 #12'S
FSD
3 #12'S
FSD
3 #12'S
FSD
3 #12'S
FSD
3 #12'S
120 VAC 120 VAC 120 VAC 120 VAC 120 VAC
3 #12'S
120 VAC
3 #12'S
120 VAC
3 #12'S
120 VAC
3 #12'S
120 VAC
3 #12'S
120 VAC
INCC-CAB
LOCAL
OPERATING
CONSOLE
4.5" DEEP19.375" WIDE
19.375" HIGH
2 PAIR #16'S TWISTED
2 PAIR #16'S TWISTED/SHIELDED
2 PAIR #16'S TWISTED
2 PAIR #16'S TWISTED/SHIELDED
LOCATED IN FOYER 1B
HS1-1
L3-115cd
2 #14'S
WATER BELL CIRCUIT
2 TO NEXT BUILDING
2
DEVICE LEGEND
S SMOKE DETECTOR
F PULL STATION
TS TAMPER SWITCH
WF WATERFLOW SWITCH
SN SIGNAL MODULE
SS SPEAKER/STROBE- WALL
R RELAY
LOCAL OPERATING CONSOLE
FACU FIRE ALARM CONTROL UNIT
NAC NAC
DESCRIPTIONCOUNTS
HS WEATHER PROOF HORN/STROBE
SYMBOL
61
2
1
15
1
19
5
11
1
FSD FIRE/SMOKE DAMPER5
WP
SS WEATHERPROOF SPEAKER/STROBEWP
LOC
FACU
E3-BB-BC/
ASM-16LCD-SLP(2)FSL-E3(2)RPT-E3
PM-9
4.5" DEEP19.375" WIDE
30" HIGH
LOCATED IN DATA ROOM 119C
DEDICATED CIRCUIT
120 VAC W/GROUND
INCC
2 CAT-6E TO NETWORK PORTS
N1L1S006
E.O.L. 3.9K
E.O.L. 3.9K
(1) HP-FF8
5.2" DEEP24" WIDE37.13" HIGH
TRANSPONDER
SBB-C4w/FCI-DR-C4B
ILI-MB-E3
AM-50INI-VGXINCC-MIC
LCD-SLP
CONDUITS& ONE 3/4"TWO 1"
4" DEEP
17" WIDE8" HIGH
MINI
BATTERY
CABINET
MMO-6SF
WEATHERPROOF WATERFLOW HORN/STROBE (P2RK)
(+)
(-)
FROM NAC PANEL
IN
(+)(-)OUT
STROBE CIRCUIT
JPK
PAYNE
TDT
(ANSI B) 1/16" = 1'
XXXX
XXXX
SP
O
R
I
A
N
N
E
X
B
U
I
L
D
I
N
G
BR
I
G
H
A
M
Y
O
U
N
G
U
N
I
V
E
R
S
I
T
Y
-
I
D
A
H
O
52
5
S
C
E
N
T
E
R
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
A
H
O
8
3
4
6
0
FI
R
E
A
L
A
R
M
S
Y
S
T
E
M
SPORI ANNEX
ADDRESSABLE
FA-1-01
SYSTEM NOTES:
TO NAC PANEL LOCATED IN DATA ROOM 119C
NELSON FIRE SYSTEMS
801-468-8300
DRAWN BY:
DESIGNED BY:
APPROVED BY:
DATE:
SCALE:
PROJECT NO:
REVISION NO:
DRAWING NAME:
NO
T
E
:
NF
S
D
R
A
W
I
N
G
S
A
R
E
B
A
S
E
D
O
N
T
H
E
P
R
O
J
E
C
T
AR
C
H
I
T
E
C
T
U
R
E
/
E
N
G
I
N
E
E
R
(
A
/
E
)
P
L
A
N
S
A
N
D
SP
E
C
I
F
I
C
A
T
I
O
N
S
F
U
R
N
I
S
H
E
D
T
O
N
F
S
.
A
/
E
I
S
S
O
L
E
L
Y
RE
S
P
O
N
S
I
B
L
E
(
N
O
T
N
F
S
)
F
O
R
T
H
E
T
Y
P
E
,
S
I
Z
E
,
LO
C
A
T
I
O
N
,
A
N
D
S
U
I
T
A
B
I
L
I
T
Y
O
F
A
L
L
F
I
R
E
A
L
A
R
M
S
,
CO
N
T
R
O
L
P
A
N
E
L
S
,
A
N
D
O
T
H
E
R
D
E
V
I
C
E
S
S
H
O
W
N
O
N
TH
E
A
/
E
P
L
A
N
S
.
N
F
S
D
R
A
W
I
N
G
S
A
R
E
T
O
S
H
O
W
O
N
L
Y
TH
E
W
I
R
I
N
G
D
I
A
G
R
A
M
S
B
E
T
W
E
E
N
F
I
R
E
A
L
A
R
M
DE
V
I
C
E
S
A
N
D
C
O
N
T
R
O
L
P
A
N
E
L
S
.
N
F
S
I
S
N
O
T
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
I
N
F
O
R
M
A
T
I
O
N
S
H
O
W
N
O
N
T
H
E
A/
E
P
L
A
N
S
.
NELSON FIRE SYSTEMS
PAGE:
25'10'50'
W E
S
N
1
SN
1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER
APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ.
CLASS "B" WIRING IS REQUIRED.
2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL
WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING
SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION
CONDITION ALLOW AND TO MINIMIZE PENETRATIONS
THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE
OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR
HIGHER CABLES ARE IN THE RACEWAY.
3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT
WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT
WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT.
FURTHERMORE, ALL PL AND NPL CKT WIRING MUST
ENTER AND EXIT THE CABINET THROUGH A DIFFERENT
KNOCKOUT AND/OR SEPARATE CONDUIT.
4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM
CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT.
5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL
TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT
INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN.
6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET
FROM MECHANICAL DIFFUSERS.
7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS.
8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE
ALARM CONTROL UNIT OR POWER SUPPLY.
9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS,
AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM
EQUIPMENT.
10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM
CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS
FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION
WILL BE NOTED AT EACH CONTROL UNIT.
GENERAL NOTES:
8/28/2020 8:43:28 AM
SPORI ANNEX.DWG
DEVICE LEGEND
S SMOKE DETECTOR
F PULL STATION
TS TAMPER SWITCH
WF WATERFLOW SWITCH
SN SIGNAL MODULE
SS SPEAKER/STROBE- WALL
R RELAY
LOCAL OPERATING CONSOLE
FACU FIRE ALARM CONTROL UNIT
NAC NAC PANEL
DESCRIPTIONCOUNTS
HS WEATHER PROOF HORN/STROBE
SYMBOL
6
1
2
1
1
5
1
1
1
FSD FIRE/SMOKE DAMPER5
WP
SS WEATHERPROOF SPEAKER/STROBEWP
LOC
WIRE SCHEDULE
NOTE DESCRIPTION WIRES
A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED
B
C
RELAY CIRCUIT 2 #14'S
D
120 VAC POWER 3 #12'S
E
SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED
LOCAL OPERATING CONSOLE 2 PAIR #16'S TWISTED
2 PAIR #16'S TWISTED/SHIELDED
F
STROBE CIRCUIT 2 #14'S
WIRING NOTE DESCRIPTION
A =2 TOTAL CONDUCTORS
(2)A =4 TOTAL CONDUCTORS
A,(2)B =6 TOTAL CONDUCTORS
G WATER BELL CIRCUIT 2 #14'S
OFFICE
100
VESTIBULE
1-A
FOYER
1-B
OFFICE
105
VESTIBULE
1-C
CERAMICS CLASSROOM
104
WOMEN'S RESTROOM
103
MEN'S RESTROOM
102
MECHANICAL & ELECTRICAL
ROOM
119B
CUSTODIAL
119A DATA ROOM
119C
SCULPTURE CLASSROOM
101
WOOD SHOP
110
KILN ROOM
112
HALLWAY
1-E
B.F.A. STUDIO
113
TOOL ROOM
114
HALLWAY
1-F
GLAZING ROOM
118
DAMP ROOM
104A
CLAY STORAGE
117A
RAKU KILN AREA
115
CLAY MIXING & DRY STORAGE
117
FOUNDRY, FORGE & WELDING
AREA
111
HALLWAY
1-D
PLASTER AREA
101B
FURNITURE STORAGE AREA
101A
MECHANICAL RISER ROOM
116
FSD FSD
FSD
FSD
FSD
F
A
C
U
F
WF TS TS
S
R R
R
R
R
1
B
2
C
CC
C
C
C
2
C
2
C
2
C
2 C
LOC
1
F
1
F
S
S
S
S
S
N
A
C
1
A
120 VAC TO RELAY FOR FIRE SMOKE DAMPER2
E.O.L. 3.9K
SEE RISER FA-R-01 FOR WATER FLOW INTERCONNECT3
3
JPK
PAYNE
TDT
(ANSI B) 1/16" = 1'
XXXX
XXXX
SP
O
R
I
A
N
N
E
X
B
U
I
L
D
I
N
G
BR
I
G
H
A
M
Y
O
U
N
G
U
N
I
V
E
R
S
I
T
Y
-
I
D
A
H
O
52
5
S
C
E
N
T
E
R
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
A
H
O
8
3
4
6
0
FI
R
E
A
L
A
R
M
S
Y
S
T
E
M
SPORI ANNEX
NOTIFICATION
FA-1-02
SYSTEM NOTES:
TO NAC PANEL LOCATED IN DATA ROOM 119C
NELSON FIRE SYSTEMS
801-468-8300
DRAWN BY:
DESIGNED BY:
APPROVED BY:
DATE:
SCALE:
PROJECT NO:
REVISION NO:
DRAWING NAME:
NO
T
E
:
NF
S
D
R
A
W
I
N
G
S
A
R
E
B
A
S
E
D
O
N
T
H
E
P
R
O
J
E
C
T
AR
C
H
I
T
E
C
T
U
R
E
/
E
N
G
I
N
E
E
R
(
A
/
E
)
P
L
A
N
S
A
N
D
SP
E
C
I
F
I
C
A
T
I
O
N
S
F
U
R
N
I
S
H
E
D
T
O
N
F
S
.
A
/
E
I
S
S
O
L
E
L
Y
RE
S
P
O
N
S
I
B
L
E
(
N
O
T
N
F
S
)
F
O
R
T
H
E
T
Y
P
E
,
S
I
Z
E
,
LO
C
A
T
I
O
N
,
A
N
D
S
U
I
T
A
B
I
L
I
T
Y
O
F
A
L
L
F
I
R
E
A
L
A
R
M
S
,
CO
N
T
R
O
L
P
A
N
E
L
S
,
A
N
D
O
T
H
E
R
D
E
V
I
C
E
S
S
H
O
W
N
O
N
TH
E
A
/
E
P
L
A
N
S
.
N
F
S
D
R
A
W
I
N
G
S
A
R
E
T
O
S
H
O
W
O
N
L
Y
TH
E
W
I
R
I
N
G
D
I
A
G
R
A
M
S
B
E
T
W
E
E
N
F
I
R
E
A
L
A
R
M
DE
V
I
C
E
S
A
N
D
C
O
N
T
R
O
L
P
A
N
E
L
S
.
N
F
S
I
S
N
O
T
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
I
N
F
O
R
M
A
T
I
O
N
S
H
O
W
N
O
N
T
H
E
A/
E
P
L
A
N
S
.
NELSON FIRE SYSTEMS
PAGE:
25'10'50'
W E
S
N
1
1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER
APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ.
CLASS "B" WIRING IS REQUIRED.
2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL
WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING
SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION
CONDITION ALLOW AND TO MINIMIZE PENETRATIONS
THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE
OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR
HIGHER CABLES ARE IN THE RACEWAY.
3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT
WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT
WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT.
FURTHERMORE, ALL PL AND NPL CKT WIRING MUST
ENTER AND EXIT THE CABINET THROUGH A DIFFERENT
KNOCKOUT AND/OR SEPARATE CONDUIT.
4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM
CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT.
5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL
TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT
INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN.
6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET
FROM MECHANICAL DIFFUSERS.
7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS.
8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE
ALARM CONTROL UNIT OR POWER SUPPLY.
9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS,
AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM
EQUIPMENT.
10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM
CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS
FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION
WILL BE NOTED AT EACH CONTROL UNIT.
GENERAL NOTES:
8/28/2020 8:43:28 AM
SPORI ANNEX.DWG
DEVICE LEGEND
S SMOKE DETECTOR
F PULL STATION
TS TAMPER SWITCH
WF WATERFLOW SWITCH
SN SIGNAL MODULE
SS SPEAKER/STROBE- WALL
R RELAY
LOCAL OPERATING CONSOLE
FACU FIRE ALARM CONTROL UNIT
NAC NAC PANEL
DESCRIPTIONCOUNTS
HS WEATHER PROOF HORN/STROBE
SYMBOL
1
19
5
1
1
1
FSD FIRE/SMOKE DAMPER
WP
SS WEATHERPROOF SPEAKER/STROBEWP
LOC
WIRE SCHEDULE
NOTE DESCRIPTION WIRES
A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED
B
C
RELAY CIRCUIT 2 #14'S
D
120 VAC POWER 3 #12'S
E
SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED
LOCAL OPERATING CONSOLE 2 PAIR #16'S TWISTED
2 PAIR #16'S TWISTED/SHIELDED
F
STROBE CIRCUIT 2 #14'S
WIRING NOTE DESCRIPTION
A =2 TOTAL CONDUCTORS
(2)A =4 TOTAL CONDUCTORS
A,(2)B =6 TOTAL CONDUCTORS
G WATER BELL CIRCUIT 2 #14'S
OFFICE
100
VESTIBULE
1-A
FOYER
1-B
OFFICE
105
VESTIBULE
1-C
CERAMICS CLASSROOM
104
WOMEN'S RESTROOM
103
MEN'S RESTROOM
102
MECHANICAL & ELECTRICAL
ROOM
119B
CUSTODIAL
119A DATA ROOM
119C
SCULPTURE CLASSROOM
101
WOOD SHOP
110
KILN ROOM
112
HALLWAY
1-E
B.F.A. STUDIO
113
TOOL ROOM
114
HALLWAY
1-F
GLAZING ROOM
118
DAMP ROOM
104A
CLAY STORAGE
117A
RAKU KILN AREA
115
CLAY MIXING & DRY STORAGE
117
FOUNDRY, FORGE & WELDING
AREA
111
HALLWAY
1-D
PLASTER AREA
101B
FURNITURE STORAGE AREA
101A
MECHANICAL RISER ROOM
116
F
A
C
U
SS
SS
SS
SS
SS
SS
SS
SSSS
SS
SS
SSSS
SS
SS
SS
SS WPSSWP
SSWP SS WP
SS WP
SP1-11/2WL1-175cd
SP1-21/2WL1-230cd
SP1-31/2WL1-330cd
SP1-41/2WL1-430cd
SP1-51/2WL1-515cd
SP1-61/2WL1-630cd
SP1-81/2WL1-815cd
SP1-91/2WL1-915cd
SP1-101/2WL1-1030cd
SP1-121/2WL1-1215cd
SP1-111/2WL1-1115cd
SP1-131/2WL1-1315cd
SP1-151/2WL2-215cdSP1-161/2WL2-375cd
SP1-171/2WL2-475cd
SP1-181/2WL2-575cd
SP1-191/2WL2-615cd
SP1-201/2WL2-775cd
SP1-241/2WL2-1175cd
SP1-231/2WL2-1075cd
SP1-221/2WL2-915cd
1
D,(2)E
E.O.L. 3.9K
E.O.L. 3.9KE.O.L. 4.7K LOC
SS
SS
SP1-141/2WL2-175cd
SS
SP1-71/2WL1-730cd
SP1-211/2WL2-875cd
HS WP
1
G
HS1-115cd
N
A
C
120 VAC TO RELAY FOR FIRE SMOKE DAMPER2
SEE RISER FA-R-01 FOR WATER FLOW INTERCONNECT3
JPK
PAYNE
TDT
(ANSI B) 1/16" = 1'
XXXX
XXXX
SP
O
R
I
A
N
N
E
X
B
U
I
L
D
I
N
G
BR
I
G
H
A
M
Y
O
U
N
G
U
N
I
V
E
R
S
I
T
Y
-
I
D
A
H
O
52
5
S
C
E
N
T
E
R
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
A
H
O
8
3
4
6
0
FI
R
E
A
L
A
R
M
S
Y
S
T
E
M
SPORI ANNEX
NUMBERS
FA-1-03
SYSTEM NOTES:
TO NAC PANEL LOCATED IN DATA ROOM 119C
NELSON FIRE SYSTEMS
801-468-8300
DRAWN BY:
DESIGNED BY:
APPROVED BY:
DATE:
SCALE:
PROJECT NO:
REVISION NO:
DRAWING NAME:
NO
T
E
:
NF
S
D
R
A
W
I
N
G
S
A
R
E
B
A
S
E
D
O
N
T
H
E
P
R
O
J
E
C
T
AR
C
H
I
T
E
C
T
U
R
E
/
E
N
G
I
N
E
E
R
(
A
/
E
)
P
L
A
N
S
A
N
D
SP
E
C
I
F
I
C
A
T
I
O
N
S
F
U
R
N
I
S
H
E
D
T
O
N
F
S
.
A
/
E
I
S
S
O
L
E
L
Y
RE
S
P
O
N
S
I
B
L
E
(
N
O
T
N
F
S
)
F
O
R
T
H
E
T
Y
P
E
,
S
I
Z
E
,
LO
C
A
T
I
O
N
,
A
N
D
S
U
I
T
A
B
I
L
I
T
Y
O
F
A
L
L
F
I
R
E
A
L
A
R
M
S
,
CO
N
T
R
O
L
P
A
N
E
L
S
,
A
N
D
O
T
H
E
R
D
E
V
I
C
E
S
S
H
O
W
N
O
N
TH
E
A
/
E
P
L
A
N
S
.
N
F
S
D
R
A
W
I
N
G
S
A
R
E
T
O
S
H
O
W
O
N
L
Y
TH
E
W
I
R
I
N
G
D
I
A
G
R
A
M
S
B
E
T
W
E
E
N
F
I
R
E
A
L
A
R
M
DE
V
I
C
E
S
A
N
D
C
O
N
T
R
O
L
P
A
N
E
L
S
.
N
F
S
I
S
N
O
T
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
I
N
F
O
R
M
A
T
I
O
N
S
H
O
W
N
O
N
T
H
E
A/
E
P
L
A
N
S
.
NELSON FIRE SYSTEMS
PAGE:
25'10'50'
W E
S
N
1
SN
1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER
APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ.
CLASS "B" WIRING IS REQUIRED.
2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL
WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING
SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION
CONDITION ALLOW AND TO MINIMIZE PENETRATIONS
THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE
OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR
HIGHER CABLES ARE IN THE RACEWAY.
3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT
WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT
WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT.
FURTHERMORE, ALL PL AND NPL CKT WIRING MUST
ENTER AND EXIT THE CABINET THROUGH A DIFFERENT
KNOCKOUT AND/OR SEPARATE CONDUIT.
4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM
CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT.
5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL
TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT
INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN.
6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET
FROM MECHANICAL DIFFUSERS.
7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS.
8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE
ALARM CONTROL UNIT OR POWER SUPPLY.
9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS,
AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM
EQUIPMENT.
10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM
CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS
FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION
WILL BE NOTED AT EACH CONTROL UNIT.
GENERAL NOTES:
8/28/2020 8:43:28 AM
SPORI ANNEX.DWG
DEVICE LEGEND
S SMOKE DETECTOR
F PULL STATION
TS TAMPER SWITCH
WF WATERFLOW SWITCH
SN SIGNAL MODULE
SS SPEAKER/STROBE- WALL
R RELAY
LOCAL OPERATING CONSOLE
FACU FIRE ALARM CONTROL UNIT
NAC NAC PANEL
DESCRIPTIONCOUNTS
HS WEATHER PROOF HORN/STROBE
SYMBOL
6
1
2
1
1
1
1
1
FSD FIRE/SMOKE DAMPER
WP
SS WEATHERPROOF SPEAKER/STROBEWP
LOC
WIRE SCHEDULE
NOTE DESCRIPTION WIRES
A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED
B
C
RELAY CIRCUIT 2 #14'S
D
120 VAC POWER 3 #12'S
E
SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED
LOCAL OPERATING CONSOLE 2 PAIR #16'S TWISTED
2 PAIR #16'S TWISTED/SHIELDED
F
STROBE CIRCUIT 2 #14'S
WIRING NOTE DESCRIPTION
A =2 TOTAL CONDUCTORS
(2)A =4 TOTAL CONDUCTORS
A,(2)B =6 TOTAL CONDUCTORS
G WATER BELL CIRCUIT 2 #14'S
OFFICE
100
VESTIBULE
1-A
FOYER
1-B
OFFICE
105
VESTIBULE
1-C
CERAMICS CLASSROOM
104
WOMEN'S RESTROOM
103
MEN'S RESTROOM
102
MECHANICAL & ELECTRICAL
ROOM
119B
CUSTODIAL
119A DATA ROOM
119C
SCULPTURE CLASSROOM
101
WOOD SHOP
110
KILN ROOM
112
HALLWAY
1-E
B.F.A. STUDIO
113
TOOL ROOM
114
HALLWAY
1-F
GLAZING ROOM
118
DAMP ROOM
104A
CLAY STORAGE
117A
RAKU KILN AREA
115
CLAY MIXING & DRY STORAGE
117
FOUNDRY, FORGE & WELDING
AREA
111
HALLWAY
1-D
PLASTER AREA
101B
FURNITURE STORAGE AREA
101A
MECHANICAL RISER ROOM
116
F
A
C
U
F
WF TS TS
S
LOC
S
S
S
S
L1S001
N1
L1S002
N1
L1S003N1
L1S004N1
L1S005N1
L1M001
N1
N1-L1M005N1-L1M006N1-L1M007
N1-L1M008
S
L1S006
N1
N
A
C
120 VAC TO RELAY FOR FIRE SMOKE DAMPER2
SEE RISER FA-R-01 FOR WATER FLOW INTERCONNECT3