HomeMy WebLinkAboutHVAC PLANS - 21-00589 - Madison Armory Indoor Gun Range.pdfMADISON ARMORY ZM001 INDEX PAGE ZM002 HVAC GENERAL NOTES ZM003 HVAC SPECIFICATIONS ZM101.1 25YD & 50YD HVAC RANGE PLAN ZM103.1 25YD & 50YD HVAC ROOF PLAN ZM501 AIRFLOW SHEMATIC ZM502 LOW VOLTAGE SCHEMATIC ZM601 MECHANICAL SCHEDULES ZM102.1 25YD & 50YD PENETRATION PLAN ZM602 MECHANICAL DETAILS ZM301.1 50YD HVAC SECTION ZM603 MECHANICAL DETAILS SCALED FOR ORIGINAL DRAWING AT 22" X 34" ZM001 MADISON ARMORY 100% SUBMITTAL SAVED: 2021-08-24 16:44:06 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM001-003-21.038.00.dwg---- Project Manager: Territory Manager: Project Engineer: Drawn By: Approved By: Origination Date: ADAM ZIEGENFELDER 08/24/2021 WILLIAM LEWIS SCOTT DESANTI WILLIAM LEWIS STEVE TIBBALS REVISION DATENoBY PROJECT STATUS PROJECT NAMEP O Box 636, Provo UT, 84603Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.comThe use of these plans shall be restricted to the original project site for which they were prepared.Publications expressly limited to such use. Re-use, reproduction, or publication by any method in wholeor part is prohibited. drawings and designs remain the property of action target inc. without reservation.Action Target Inc. 2021 All Rights ReservedDRAWING NUMBER SHEET NAME SHEET NUMBER SHEET INDEX Signature: Printed Name: Date: CUSTOMER APPROVAL: NOTWITHSTANDING THE CONTRACT DOCUMENTS, APPROVAL OF THESE DRAWINGS SHALL ACT AS AN AMENDMENT TO THE PARTIES' AGREEMENT AND SUPERSEDE ALL PREVIOUS DRAWINGS. MECHANICAL ABBREVIATIONS INDEX AP MECHANICAL DUCT SYMBOLS DESIGN CONTACTS GENERAL NOTES: 1.EACH DRAWING HAS SPECIFIC KEYED AND GENERAL NOTES. THE NOTES ON THIS DRAWING ARE GENERAL IN NATURE AND APPLY TO WORK DESCRIBED IN ALL THE RANGE VENTILATION DRAWINGS AND SPECIFICATIONS. 2.THE RANGE VENTILATION DUCT ROUTING SHOWN IS APPROXIMATE AND DIAGRAMMATIC AND IS NOT TO BE SCALED. MINOR ALTERATIONS ARE ALLOWED TO AVOID LOCAL INTERFERENCES. WHERE FIELD CONDITIONS REQUIRE SUBSTANTIAL CHANGES TO THE DUCT LAYOUT, CHANGES MUST BE APPROVED BY ACTION TARGET. 3.THIS PROJECT AND ALL WORK SHALL CONFORM TO ALL LOCAL AND NATIONAL CODES AND STANDARDS WHICH ARE APPLICABLE TO THIS TYPE OF WORK, SOME OF WHICH ARE AS FOLLOWS: LOCAL AND NATIONAL BUILDING AND MECHANICAL CODES, NFPA, ASHRAE, SMACNA AND OTHER REGULATORY BODIES HAVING JURISDICTION OVER THIS TYPE OF WORK. ALL SYSTEMS INCLUDING MATERIALS, EQUIPMENT AND WORKMANSHIP SHALL CONFORM TO THE ASSOCIATED CODES AND REGULATIONS OF GOVERNING BODIES, CODES AND REGULATIONS OF THE ASSOCIATED MUNICIPAL, STATE AND FEDERAL AUTHORITIES. 4.THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, LICENSES, AND UTILITY SERVICE AGREEMENTS RELATED TO THE INSTALLATION, COMMISSIONING, TESTING AND BALANCING FOR THE COMPLETION OF THIS WORK. THE CONTRACTOR SHALL ASSIST AND WORK WITH THE OWNER TO OBTAIN OWNER SPECIFIC PERMITS, LICENSES AND AGREEMENTS. 5.THE CONTRACTOR SHALL COORDINATE THE RANGE VENTILATION WORK WILL ALL BUILDING PLUMBING, ELECTRICAL, AND STRUCTURAL TRADES TO PROVIDE ALL THE NECESSARY UTILITY CONNECTIONS FOR THE RANGE VENTILATION EQUIPMENT. COORDINATE THIS WORK WITH ALL OTHER TRADES IN ORDER TO RESOLVE ANY CONFLICTS THAT MIGHT ARISE DUE TO THE INSTALLATION AND LOCATION OF DUCTWORK, PIPING, CONTROLS OR EQUIPMENT THAT IS TO BE INSTALLED AS PART OF THIS PROJECT. 6.THE GENERAL CONTRACTOR OR OTHER DIVISIONS WILL INSURE THAT THE RANGE ENVELOPE IS SEALED TIGHT TO MAINTAIN THE REQUIRED NEGATIVE SPACE PRESSURE AS SPECIFIED ON THE DRAWINGS AND IN THE SPECIFICATIONS. 7.ALL WALL AND ROOF PENETRATIONS FOR DUCTWORK AND OTHER RELATED OPENINGS SHALL BE COMPLETED BY THE GENERAL CONTRACTOR OR BY THE OWNER. PROVIDE ROOF CURBS FOR ALL ROOF DUCT PENETRATIONS AND FLASH WATER TIGHT. 8.THE EQUIPMENT PADS AND STRUCTURAL SUPPORTS WILL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR OR BY THE OWNER. 9.DUCTWORK, PIPING, CONTROLS AND EQUIPMENT INCLUDING FILTER HOUSING SHALL BE INSTALLED SUCH THAT THEY CAN BE SERVICED AND REPAIRED OR REPLACED BY ANY PERSON ASSOCIATED WITH THIS PROJECT, INCLUDING THE OWNER AND THE OWNERS REPRESENTATIVE. 10.ALL DUCTWORK, SUPPLY, EXHAUST AND RETURN SHALL BE SEALED AS DESCRIBED IN THE DRAWINGS AND IN THE SPECIFICATIONS AND PER SMACNA STANDARDS. 11.ALL DUCTWORK NEEDS TO BE RATED AT A MINIMUM OF 2” WC STATIC PRESSURE. THE DUCTWORK CONNECTING TO THE RANGE EXHAUST FANS AND THE FILTER HOUSING IS RATED AT A MINIMUM OF -8” WC STATIC PRESSURE. SEE DRAWINGS AND SPECIFICATIONS AND SMACNA STANDARDS FOR THE CONSTRUCTION AND INSTALLATION OF ALL DUCTWORK. 12.ALL DUCTWORK SIZES ARE INSIDE CLEAR DIMENSIONS. IF INSULATION LINING IS NOTED THE DUCTWORK SHALL BE INCREASED IN SIZE TO ALLOW FOR THE INSULATION. 13.ALL DUCTWORK ELBOWS SHALL BE RADIUS ELBOWS UNLESS NOTED OTHERWISE. WHERE SQUARE ELBOWS ARE SHOWN THEY SHALL HAVE SINGLE BLADE TURNING VANES. ROUTE ALL DUCTWORK AS HIGH AS POSSIBLE ABOVE BALLISTIC BAFFLES. COORDINATE DUCT INSTALL WITH CEILING SUPPORT SYSTEM. DUCTWORK SIZE CHANGES ARE ALLOWED AS LONG AS THE FREE AREA IS NOT REDUCED. SUBMIT COORDINATED SHEET METAL SHOP DRAWINGS FOR APPROVAL BEFORE FABRICATION OF DUCTWORK SYSTEMS. SHOP DRAWINGS SHALL BE APPROVED BY ACTION TARGET INC (ATI). ALL OFF- SETS, RISERS OR DROPS ARE TO BE INDICATED ON THE SHOP DRAWINGS. 14.THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT AND WIRING FROM THE POWER SOURCES TO THE EQUIPMENT DISCONNECT AND FROM THE DISCONNECT SWITCHES TO STARTERS AND FROM STARTERS TO THE EQUIPMENT. 15.ALL HIGH VOLTAGE CONDUITS AND WIRING SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 16.ALL LOW VOLTAGE CONDUITS AND WIRING SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 17.AUTOMATIC CONTROL DEVICES, SUCH AS TEMPERATURE SENSORS, RELAYS AND PRESSURE SWITCHES WHICH ARE ASSOCIATED WITH THIS WORK AND THESE SYSTEMS AND SHALL BE FURNISHED AND INSTALLED BY THIS DIVISION. 18.ALL CONTROL WIRING SHALL BE RUN CONCEALED WHEN POSSIBLE. WIRING IN WALLS SHALL BE IN CONDUIT. ALL CONTROL WIRING SHALL BE PLENUM RATED. CONTROL WIRING IN EXPOSED AREAS SHALL BE RUN IN CONDUIT. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODES AND ANY OTHER LOCAL OR STATE CODES. 19.FIELD VERIFY LOCATIONS OF ALL RANGE MECHANICAL EQUIPMENT, ROOF PENETRATIONS, AND DEVICES PRIOR TO FABRICATION OR STARTING NEW WORK. MECHANICAL CONTRACTOR SHALL COORDINATE WITH OWNERS GENERAL CONTRACTOR AND STRUCTURAL ENGINEER ALL SUPPORTING STEEL FOR MECHANICAL EQUIPMENT. GENERAL CONTRACTOR TO FURNISH AND INSTALL SUPPORT ANGLES AND SUPPORT BEAMS FOR MECHANICAL EQUIPMENT. 20.THE CONTRACTOR SHALL INSTALL THE RANGE MECHANICAL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION GUIDELINES AND STANDARDS. MAINTAIN THE MANUFACTURER'S OPERATIONAL AND SERVICE CLEARANCES AROUND EQUIPMENT. 21.ALL RANGE MECHANICAL SYSTEMS SHALL BE TESTED, COMMISSIONED AND SHALL BE COMPLETE AND FUNCTIONAL AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR SHALL WARRANTY HIS WORK FOR A PERIOD OF TWELVE (12) MONTHS FROM DATE OF FINAL ACCEPTANCE. 22.THIS WORK SHALL INCLUDE ALL THE PRODUCTS AND EQUIPMENT FOR COMPLETE AND FUNCTIONAL SYSTEMS FOR THE AREAS INDICTED IN THESE DOCUMENTS. OWNER/CONTRACTOR TO PROVIDE · · STRUCTURAL · · · · ELECTRICAL · · · · · MECHANICAL · MISCELLANEOUS · · · · · · · · · ATTENTION: REQUIRED INFORMATION: THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE PROVIDED TO SHOW GENERAL INTENT OF THE VENTILATION EQUIPMENT AND DUCT LAYOUT. ACTUAL EQUIPMENT AND DUCT SIZE WILL BE DETERMINED DURING DETAILED DESIGN AND MAY VARY FROM THE SIZES SHOWN ON THESE DRAWINGS. ACTION TARGET'S DESIGNERS/ENGINEERS WILL NEED TO COORDINATE WITH THE CUSTOMER'S STRUCTURAL ENGINEER, ARCHITECT, AND CONTRACTOR THE LAYOUT OF THE VENTILATION SYSTEM AND SCOPE OF WORK. PROVIDE ACTION TARGET WITH BUILDING DRAWINGS OF THE RANGE SPACE. PLANS AND SECTION VIEWS IN AUTOCAD FORMAT. (PDF FILES OR HAND SKETCHES ARE REQUIRED WHEN AUTOCAD FILES ARE NOT AVAILABLE.) ACTION TARGET ROUTES VENTILATION DUCTING BETWEEN THE STEEL BAFFLES AND THE BOTTOM OF THE RANGE CEILING STRUCTURE. THE MINIMUM CLEAR DISTANCE FROM THE FLOOR TO THE BOTTOM OF THE RANGE ROOF STRUCTURAL MEMBERS (TRUSSES, ETC.) IS 14'-0". COMPLETE ACTION TARGET HVAC SURVEY WITH SALES ASSOCIATE AND/OR PROJECT MANAGER. ALL PERMITS AND LICENSES PERTAINING TO PROJECT. STRUCTURAL SUPPORT OF MECHANICAL VENTILATION EQUIPMENT. CONCRETE EQUIPMENT PADS FOR MECHANICAL VENTILATION EQUIPMENT, IF APPLICABLE. WALL PENETRATIONS FOR VENTILATION DUCTING ROOF PENETRATIONS, PATCHING, AND ROOFING AROUND DUCT ROOF CURBING AND EQUIPMENT SUPPORTS OF MECHANICAL EQUIPMENT. FLASH AND WATER TIGHT SEAL. MATERIAL AND INSTALL OF HIGH AND LOW VOLTAGE WIRE AND CONDUIT FOR VENTILATION EQUIPMENT. ELECTRICAL DISCONNECTS FOR MECHANICAL EQUIPMENT. DEDICATED 120V CIRCUIT TO VENTILATION CONTROL PANEL. INSTALLATION OF ATI PROVIDED VFD'S AND CONTROL/RANGE DISPLAY PANELS. INTERNET STATIC IP ADDRESS FOR REMOTE CONTROL ACCESS. CAT5 CABLE TO RANGE CONTROL PANEL. ALL GAS PIPE (SIZED FOR MECHANICAL EQUIPMENT), REGULATORS & FINAL CONNECTIONS AND HOOKUPS FOR RANGE MECHANICAL EQUIPMENT PROVIDE AN AIR TIGHT RANGE ENVELOPE. SEAL ALL HOLES, PENETRATIONS, DOORWAYS, DOOR JAMS, AND OPENINGS IN RANGE WALLS, WALL TO ROOF CONNECTIONS, AND ALL ROOF OPENINGS. T-BAR CEILING BETWEEN SAFETY CEILING AND RANGE DIFFUSERS. ANY FIRE/SMOKE DEVICES REQUIRED BY LOCAL JURISDICTION. NOTE: THIS LIST IS PROVIDED TO IDENTIFY AND COORDINATE THE SCOPE OF WORK FOR THE RANGE VENTILATION SYSTEM. A COMPLETE AND DETAILED LIST WILL BE PROVIDED UPON CONTRACT. MECHANICAL CALLOUTS SCALED FOR ORIGINAL DRAWING AT 22" X 34" ZM002 MADISON ARMORY 100% SUBMITTAL SAVED: 2021-08-24 16:44:06 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM001-003-21.038.00.dwg---- Project Manager: Territory Manager: Project Engineer: Drawn By: Approved By: Origination Date: ADAM ZIEGENFELDER 08/24/2021 WILLIAM LEWIS SCOTT DESANTI WILLIAM LEWIS STEVE TIBBALS REVISION DATENoBY PROJECT STATUS PROJECT NAMEP O Box 636, Provo UT, 84603Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.comThe use of these plans shall be restricted to the original project site for which they were prepared.Publications expressly limited to such use. Re-use, reproduction, or publication by any method in wholeor part is prohibited. drawings and designs remain the property of action target inc. without reservation.Action Target Inc. 2021 All Rights ReservedDRAWING NUMBER SHEET NAME SHEET NUMBER SYMBOLS, ABBREVIATIONS, & NOTES · ALL DIMENSIONS SHOWN ARE IN FEET AND INCHES. IT SHALL BE THE RESPONSIBILITY OF THE AWARDED CONTRACTOR TO PROVIDE COMPLETE SHOP DRAWINGS OF THE SYSTEMS OUTLINED WITHIN THESE BID SPEC DOCUMENTS. SHOP DRAWINGS SHALL INCLUDE, BUT NOT LIMITED TO: EQUIPMENT CUT SHEETS, MATERIALS CUT SHEETS, EQUIPMENT LOCATIONS AND DIMENSIONS, DUCTWORK ROUTING AND DIMENSIONS, HANGING/BRACING/MOUNTING METHODS, CONTRACTOR CERTIFICATIONS, ETC. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO ENGINEER FOR REVIEW AND APPROVAL PRIOR TO ACQUISITION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRED. SPECIFICATIONS: 1.SECTION 23000 GENERAL REQUIREMENTS. 2.THIS WORK SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, FIXTURES, AND DEVICES FOR THE ENTIRE MECHANICAL WORK AND A COMPLETE OPERATING AND TESTED INSTALLATION AS REQUIRED FOR THIS PROJECT. 3.ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL LOCAL AND STATE RULES AND REGULATIONS APPLICABLE TO THE TRADE AFFECTED. AFTER ENTERING INTO THIS CONTRACT, THE CONTRACTOR WILL COMPLETE ALL WORK NECESSARY TO MEET THESE REQUIREMENTS WITHOUT EXTRA EXPENSES TO THE OWNER. 4.APPLICABLE CODES SHALL BE THE LATEST EDITION OF IBC, IMC, IPC, AND IFC. INDUSTRY STANDARDS SHALL BE AS FOLLOWS: ARI, ADC, AMCA, AGA, ANSI, ASHRAE, ASME, ASTM, AWWA, ETL, IEEE, NFPA, NEC, NEMA, NESC OSHA, SMACNA, AND UL. 5.THE CONTRACTOR SHALL OBTAIN THE NECESSARY PERMITS TO PERFORM THIS WORK. 6.SHOP DRAWINGS AND COORDINATION DRAWING SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER AND ATI FOR REVIEW AND MUST BE COORDINATE WITH ALL OTHER TRADES. SHOP DRAWINGS SHALL INCLUDED PLANS, ELEVATIONS, SECTIONS AND INDICATE PRESSURE CLASS. DRAWINGS SHALL ALSO INCLUDE FITTINGS, REINFORCING AND SPACING, SEAM AND JOINT CONSTRUCTION DETAILS. PENETRATIONS THROUGH PARTITIONS AND FIRE-RATE WALLS SHALL BE INDICATED. HANGERS AND SUPPORTS WITH BUILDING ATTACHMENT AS WELL AS VIBRATION ISOLATION SHALL ALSO BE INCLUDED. SHEETMETAL SHOP DRAWINGS WILL BE REQUIRED FOR ALL DUCTWORK IN THE ENTIRE BUILDING. THESE DRAWINGS SHALL BE COORDINATED WITH ALL PIPING, CONDUIT, VALVES, EQUIPMENT AND DUCTWORK. 7.THE CONTRACT DRAWINGS SHOW THE GENERAL DESIGN ARRANGEMENTS AND THE EXTENT OF THE SYSTEMS. THE DRAWINGS MAY INCLUDE DETAILS THAT SHOW MORE NEARLY EXACT LOCATIONS AND ARRANGEMENTS; HOWEVER, THE LOCATIONS ARE SHOWN DIAGRAMMATICALLY, AND ARE TO BE REGARDED AS GENERAL. IT SHALL BE THE WORK OF THIS CONTRACTOR TO MAKE SUCH SLIGHT ALTERATIONS AS MAY BE NECESSARY TO MAKE COMPONENTS AND SYSTEMS FIT. THE DRAWINGS SHALL NOT BE SCALED FOR ROUGHING IN MEASUREMENTS NOR SHALL THEY BE USED AS SHOP DRAWINGS. 8.EXISTING CONDITIONS SHALL BE CAREFULLY EXAMINED BY THIS CONTRACTOR. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL EXISTING SERVICES AND UNDERSTAND THE STRUCTURAL AND ELECTRICAL DRAWINGS AND REQUIREMENTS NEEDED TO COMPLETE THIS WORK. 9.THE EQUIPMENT CAPACITIES SHOWN FOR THE EQUIPMENT IS THE MINIMUM ACCEPTABLE. ALL EQUIPMENT SUBMITTALS SHALL GIVE THE SPECIFIED CAPACITY AND PERFORMANCE AT THE GIVEN JOB-SITE ELEVATION. 10.ALL EQUIPMENT SHALL BE FURNISHED AND INSTALLED STRUCTURALLY ADEQUATE TO WITHSTAND THE SEISMIC FORCES AS OUTLINED IN THE INTERNATIONATIONAL BUILDING CODE AND THE SMACNA GUIDELINES FOR THE AREA WHICH THIS PROJECT IS BEING CONSTRUCTED. 11.THE CONTRACTOR SHALL REFER TO OTHER DRAWINGS AND PARTS OF THIS SPECIFICATION THAT COVER WORK OF OTHER TRADES THAT IS CARRIED ON IN CONJUNCTION WITH THE MECHANICAL WORK SUCH THAT ALL WORK CAN PROCEED WITHOUT INTERFERENCE RESULTING FORM LACK OF COORDINATION. THE CEILING CAVITY MUST BE CAREFULLY REVIEWED AND COORDINATED WITH ALL TRADES. THIS CONTRACTOR SHALL INSURE THAT THE INSTALLATION OF ALL DUCTWORK, PIPING AND EQUIPMENT IS IN COMPLIANCE WITH ARTICLES 110-16 AND 384-4 OF THE NATIONAL ELECTRICAL CODE RELATIVE TO PROPER CLEARANCES IN FRONT OF AND OVER ALL ELECTRICAL PANELS AND EQUIPMENT. NO PIPING OR DUCTWORK SHALL BE ALLOWED TO RUN OVER ELECTRICAL PANELS. 12.THE CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF A SATISFACTORY PIECE OF WORK IN ACCORDANCE WITH THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONS. HE SHALL PROVIDE AS A PART OF HIS WORK AND WITHOUT EXPENSE, ALL INCIDENTAL ITEMS REQUIRED EVEN THOUGH THESE ITEMS ARE NOT PARTICULARLY SPECIFIED OR INDICATED. THE INSTALLATION SHALL BE MADE SO THAT SEVERAL COMPONENT PARTS WILL FUNCTION TOGETHER AS A WORKABLE SYSTEM AND SHALL BE LEFT WITH ALL EQUIPMENT PROPERLY ADJUSTED AND IN WORKING ORDER. THE CONTRACTOR SHALL FAMILIARIZE THE OWNER’S REPRESENTATIVE WITH MAINTENANCE AND LUBRICATION INSTRUCTIONS AS PREPARED BY THE CONTRACTOR AND SHALL EXPLAIN AND FULLY INSTRUCT HIM RELATIVE TO OPERATING, SERVICING, AND MAINTENANCE OF EACH ITEM. 13.WORKMANSHIP SHALL BE THE BEST QUALITY OF ITS KIND FOR THE RESPECTIVE INDUSTRIES, TRADE, CRAFTS, AND PRACTICES, AND SHALL BE ACCEPTABLE IN EVERY RESPECT TO THE OWNERS REPRESENTATIVE. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL, AND OSHA SAFETY REQUIREMENTS IN PERFORMANCE WITH THIS WORK. 14.THE ACCESS TO EQUIPMENT SHOWN ON THE DRAWINGS IS THE MINIMUM ACCEPTABLE SPACE REQUIREMENTS. ALL OPEN DUCT AND PIPE OPENINGS SHALL BE ADEQUATELY COVERED AT ALL TIME TO PREVENT ITEMS FROM ENTERING. 15.NO CUTTING OR DRILLING IN STRUCTURAL MEMBERS SHALL BE DONE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. 16.ALL FLOOR MOUNTED MECHANICAL EQUIPMENT SHALL BE SET ON 6-INCH HIGH CONCRETE BASE, UNLESS OTHERWISE NOTED OR SHOWN ON DRAWINGS. THE UNISTRUT INSERT OF DUCTWORK AND PIPING SYSTEMS SHALL INCLUDE ALL INSERTS, VERTICAL SUPPORTS, HORIZONTAL SUPPORT MEMBERS, CLAMPS, HANGERS, ROLLERS, BOLTS, NUTS AND ANY OTHER ACCESSORY ITEMS FOR A COMPLETE SUPPORTING SYSTEM. 17.UPON COMPLETION OF THIS WORK REMOVE ALL SURPLUS MATERIAL AND RUBBISH RESULTING FROM THIS WORK AND LEAVE THE PREMISES IN A CLEAN AND ORDERLY CONDITION. 18.THE ENTIRE MECHANICAL SYSTEM INCLUDING PLUMBING AND HVAC SYSTEMS SHALL BE QUITE IN OPERATION. THE CONTRACTOR SHALL MAKE PROMPTLY AND FREE OF CHARGE, UPON NOTICE FROM THE OWNER, ANY NECESSARY REPAIRS DUE TO DEFECTIVE WORKMANSHIP OR MATERIALS THAT MAY OCCUR DURING A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. 19.PRE FILTERS USED DURING CONSTRUCTION AND TESTING SHALL BE REPLACED PRIOR TO TURNING THE SYSTEM OVER TO THE OWNER. 20.SECTION 230100 OPERATION AND MAINTENANCE MANUALS 21.THE CONTRACTOR SHALL TURN OVER TO THE OWNER THE OPERATION AND MAINTENANCE MANUALS WITH THE BALANCING REPORTS. THE MANUALS SHALL INCLUDE AIR-BALANCING REPORTS, SYSTEM COMMISSIONING PROCEDURES, START-UP TESTS AND REPORTS. ALSO INCLUDED SHALL BE THE EQUIPMENT AND SYSTEM PERFORMANCE TEST REPORTS AND WARRANTIES. 22.SECTION 233001 METAL DUCTS. 23.THIS SECTION INCLUDES RECTANGULAR AND ROUND METAL DUCTWORK FOR VENTILATING, AIR CONDITIONING SYSTEMS IN PRESSURE CLASSES FROM MINUS 2 INCHES TO PLUS 10 INCHES WATER GAGE. 24.THE DUCT SYSTEM DESIGNS, AS INDICATED, HAVE BEEN USED TO SELECT AND SIZE AIR MOVING AND DISTRIBUTION EQUIPMENT AND OTHER COMPONENTS OF THE HVAC AIR SYSTEM. CHANGES OR ALTERATIONS TO THE LAYOUT OR CONFIGURATION OF THE DUCT SYSTEM MUST BE SPECIFICALLY APPROVED IN WRITING. APPROVED LAYOUT MODIFICATIONS PROPOSED MUST BE WITHOUT INCREASING THE SYSTEM TOTAL STATIC PRESSURE. 25.THE GENERAL FABRICATION REQUIREMENTS SHALL ALSO COMPLY WITH ALL SMACNA’S HVAC DUCT CONSTRUCTION STANDARDS. CONSTRUCTION SHALL BE BASED ON STATIC PRESSURES INDICATED ON THE SCHEDULES, DRAWINGS AND SPECIFICATIONS. TYPICAL TOTAL STATIC PRESSURE OF THE SUPPLY FAN SYSTEMS ARE IN THE 3.5” RANGE AND THE EXHAUST SYSTEMS ARE TYPICALLY IN THE 7.5” RANGE, SEE SCHEDULES FOR EXACT PRESSURES. COMPLIANCE OF THIS WORK SHALL ALSO CONFORM TO NFPA STANDARD 90A. 26.TRANSVERSE JOINTS: SELECT JOINT TYPES AND FABRICATE ACCORDING TO “SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” FIGURE 2-1, RECTANGULAR DUCT/TRANSVERSE JOINTS FOR STATIC-PRESSURE CLASS AS REQUIRED FOR THIS PROJECT, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT SUPPORT INTERVALS, AND OTHER PROVISIONS ARE TO BE PER THE SMACNA STANDARDS. 27.LONGITUDINAL SEAMS: SELECT SEAM TYPES AND FABRICATE ACCORDING TO SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” FIGURE 2-2, “RECTANGULAR DUCT/LONGITUDINAL SEAMS,” FOR STATIC-PRESSURE CLASS FOR THIS PROJECT, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND OTHER PROVISIONS ARE TO BE PER THE SMACNA STANDARDS. 28.ELBOWS, TRANSITIONS, OFFSETS, BRANCH CONNECTIONS, AND OTHER DUCT CONSTRUCTION: SELECT TYPES AND FABRICATE ACCORDING TO SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” CHAPTER 4, “FITTINGS AND OTHER CONSTRUCTION” FOR STATIC-PRESSURE CLASS FOR THIS PROJECT, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND OTHER PROVISIONS ARE TO BE PER SMACNA STANDARDS. 29.ROUND DUCTS AND FITTINGS, GENERAL FABRICATION REQUIREMENTS: COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” CHAPTER 3, “ROUND, OVAL, AND FLEXIBLE DUCT” BASED ON INDICATED STATIC-PRESSURE CLASS FOR THIS PROJECT. 30.TRANSVERSE JOINTS: SELECT JOINT TYPES AND FABRICATE ACCORDING TO SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” FIGURE 3-1, “ROUND DUCT TRANSVERSE JOINTS,” FOR STATIC PRESSURE CLASS FOR THIS PROJECT, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND OTHER PROVISIONS PER SMACNA STANDARDS. 31.LONGITUDINAL SEAMS: SELECT SEAM TYPES AND FABRICATE ACCORDING TO SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE”, FIGURE 3-2, “ROUND DUCT LONGITUDINAL SEAMS,” FOR STATIC-PRESSURE CLASS FOR THIS PROJECT APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED DUCT-SUPPORT INTERVALS, AND OTHER PROVISIONS AS PER SMACNA STANDARDS. 32.TEES AND LATERALS: SELECT TYPES AND FABRICATE ACCORDING TO SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” FIGURE 3-5, “90 DEGREE TEES AND LATERALS,” AND FIGURE 3-6 “CONICAL TEES,” FOR STATIC-PRESSURE CLASS PER THIS PROJECT, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND OTHER PROVISIONS PER SMACNA STANDARDS. 33.SHEET METAL MATERIALS, GENERAL MATERIAL REQUIREMENTS: COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE” FOR ACCEPTABLE MATERIALS, MATERIAL THICKNESS, AND DUCT CONSTRUCTION METHODS UNLESS OTHERWISE INDICATED. SHEET METAL MATERIALS SHALL NEW PRODUCT WITHOUT IMPERFECTIONS. GALVANIZED SHEET STEEL: COMPLY WITH ASTM A 653. GALVANIZED COATING DESIGNATION: G60. REINFORCEMENT SHAPES AND PLATES: COMPLY WITH ASTM A 36, STEEL PLATES, SHAPES, AND BARS: BLACK AND GALVANIZED. TIE RODS: GALVANIZED STEEL, ¼-INCH MINIMUM DIAMETER FOR LENGTHS 36 INCHES OR LESS; ⅜-INCH MINIMUM DIAMETER FOR LENGTHS LONGER THAN 36 INCHES. 34.SEALANT AND GASKETS, GENERAL SEALANT AND GASKET REQUIREMENTS: SURFACE-BURNING CHARACTERISTICS FOR SEALANTS AND GASKETS SHALL HAVE A MINIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED ACCORDING TO UL723; CERTIFIED BY AN NRTL. USE A TWO PART TAPE SEALING SYSTEM OR A WATER BASED JOINT AND SEAM SEALANT. FLANGED JOINT SEALANT SHALL COMPLY WITH ASTM C 920. 35.HANGERS AND SUPPORTS, HANGER RODS: CADMIUM-PLATED STEEL RODS AND NUTS. STRAP AND ROD SIZES: COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” TABLE 5-1, “RECTANGULAR DUCT HANGERS MINIMUM SIZE,” AND TABLE 5-2, “MINIMUM HANGER SIZES FOR ROUND DUCT.” 36.STEEL CABLES FOR GALVANIZED-STEEL DUCTS: GALVANIZED STEEL COMPLYING WITH ASTM A 603.STEEL CABLE END CONNECTIONS: CADMIUM-PLATED STEEL ASSEMBLIES WITH BRACKETS, SWIVEL, AND BOLTS DESIGNED FOR DUCT HANGER SERVICE: WITH AN AUTOMATIC-LOCKING AND CLAMPING DEVICE.DUCT ATTACHMENTS: SHEET METAL SCREWS, BLIND RIVETS, OR SELF-TAPPING METAL SCREWS: COMPATIBLE WITH DUCT MATERIALS. 37.TRAPEZE AND RISER SUPPORTS FOR GALVANIZED-STEEL DUCTS SHALL BE USED AS NEED AND ARE TO BE GALVANIZED - STEEL SHAPES AND PLATES. WIRE HANGERS ARE NOT ALLOWED. USE THREADED ROD TO STEEL JOIST WITH ANVIL STEEL WASHERS AND DOUBLE NUT CONNECTION. ONE INCH 18 GA GALVANIZED STEEL STRAPS ARE ALLOWED FOR SMALLER SINGLE RUN DUCTWORK. 38.INSTALL DUCTS ACCORDING TO SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE” UNLESS OTHERWISE INDICATED. DUCTWORK IS TO BE INSTALLED WITH FEWEST JOINTS AS POSSIBLE. SHOP AND PRE FABRICATED THE FITTINGS WHENEVER POSSIBLE. PREFABRICATED FITTINGS ARE TO BE USED FOR CHANGES IN DIRECTIONS AND BRANCH CONNECTIONS. UNLESS OTHERWISE INDICATED, INSTALL DUCTS VERTICALLY AND HORIZONTALLY, AND PARALLEL AND PERPENDICULAR TO BUILDING LINES AND WALLS. INSTALL DUCTS WITH A CLEARANCE AT LEAST 1 INCH, PLUS ALLOWANCE FOR INSULATION THICKNESS WHEN NOTE IN THE SPECIFICATIONS OR DRAWINGS. WHERE DUCTS PASS THROUGH EXTERIOR WALLS AND ARE EXPOSED TO THE OUTSIDE OR VIEW, COVER THE OPENING BETWEEN THE WALL AND DUCT OR DUCT INSULATION WITH SHEET METAL FLANGES OF SAME METAL THICKNESS AS THE DUCT. OVERLAP OPENINGS ON FOUR SIDES BY AT LEAST 1-½ INCHES. DURING CONSTRUCTION PROTECT DUCT INTERIORS FROM MOISTURE, CONSTRUCTION DEBRIS AND DUST, AND OTHER FOREIGN MATERIALS AT ALL TIMES. 39.DUCT SEALING SHALL BE FOR THE DUCT STATIC PRESSURES, SEAL CLASSES, AND LEAKAGE CLASSES SPECIFIED IN “DUCT CONSTRUCTION SCHEDULE” ACCORDING TO SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE.” THE CONTRACTOR SHALL COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” CHAPTER 5, “HANGERS AND SUPPORTS.” 40.THIS CONTRACTOR NEEDS TO GET APPROVAL FROM THE STRUCTURAL ENGINEER ON ATTACHMENT SELECTION AND SPACING OF THE SYSTEMS HE WANTS TO INSTALL AND THE SUPPORTING OF THE DUCTWORK FROM THE STRUCTURE. BUILDING ATTACHMENTS SHALL BE CONCRETE INSERTS, POWDER-ACTUATED FASTENERS, OR STRUCTURAL-STEEL FASTENERS APPROPRIATE FOR CONSTRUCTION MATERIALS TO WHICH HANGERS ARE BEING ATTACHED. IF CONSTRUCTION PHASING ALLOWS INSTALL CONCRETE INSERTS BEFORE PLACING CONCRETE IT IS PREFERRED. POWDER-ACTUATED CONCRETE FASTENERS ARE TO BE INSTALLED AFTER CONCRETE IS PLACED AND COMPLETELY CURED. ONLY USE POWDER-ACTUATED CONCRETE FASTENERS FOR STANDARD-WEIGHT AGGREGATE CONCRETE OR FOR SLABS MORE WHICH HAVE A THICKNESS GREATER THAN 4 INCHES. POWDER-ACTUATED CONCRETE FASTENERS ARE NOT TO BE USED FOR LIGHTWEIGHT-AGGREGATE CONCRETES OR FOR SLABS LESS THAN 4 INCHES THICK. 41.HANGER SPACING: COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” TABLE 5-1, “RECTANGULAR DUCT HANGERS MINIMUM SIZE,” AND TABLE 5-2, “MINIMUM HANGER SIZES FOR ROUND DUCT,” FOR MAXIMUM HANGER SPACING; INSTALL HANGERS AND SUPPORTS WITHIN 24 INCHES OF EACH ELBOW AND WITHIN 48 INCHES OF EACH BRANCH INTERSECTION. IF THE HANGERS ARE EXPOSED TO VIEW THEY SHALL BE THREADED ROD AND ANGLE OR CHANNEL SUPPORTS. INSTALL UPPER ATTACHMENTS TO STRUCTURES. SELECT AND SIZE UPPER ATTACHMENTS WITH PULL-OUT, TENSION, AND SHEAR CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED. 42.COORDINATE DUCT INSTALLATIONS AND SPECIALTY ARRANGEMENTS WITH DRAWINGS. MAKE DUCTWORK CONNECTIONS TO EQUIPMENT WITH FLEXIBLE CONNECTORS FOR THE RATED PRESSURE AND USE INDOOR OR OUTDOOR. COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE” FOR BRANCH, OUTLET AND INLET, AND FAN OR UNIT CONNECTIONS. 43.FABRICATE DUCTS WITH GALVANIZED SHEET STEEL EXCEPT AS OTHERWISE INDICATED AND AS FOLLOWS: ELBOW CONFIGURATION - RECTANGULAR DUCT: COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” FIGURE 4-2 “RECTANGULAR ELBOWS.” BRANCH CONFIGURATION - RECTANGULAR DUCT: COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,” FIGURE 4-6, “BRANCH CONNECTIONS.” RECTANGULAR MAIN TO RECTANGULAR BRANCH: 45-DEGREE ENTRY.RECTANGULAR MAIN TO ROUND BRANCH PROVIDE A 45 DEGREE TYPE TAKE-OFF. 44.SECTION 233300 AIR DUCT ACCESSORIES. 45.GENERAL, COMPLY WITH NFPA 90A, “INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS,” AND WITH NFPA 90B, “INSTALLATION OF WARM AIR HEATING AND AIR CONDITIONING SYSTEMS.” COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE”FOR ACCEPTABLE MATERIALS, MATERIAL THICKNESSES, AND DUCT CONSTRUCTION METHODS UNLESS OTHERWISE INDICATED. SHEET METAL MATERIALS SHALL BE FREE OF PITTING, SEAM MARKS, STAINS, DISCOLORATIONS, AND OTHER IMPERFECTIONS. MATERIALS, GALVANIZED SHEET STEEL: COMPLY WITH ASTM A 653, GALVANIZED COATING DESIGNATION G60. REINFORCEMENT SHAPES AND PLATES: GALVANIZED - STEEL REINFORCEMENT WHERE INSTALLED ON GALVANIZED SHEET METAL DUCTS: TIE RODS SHALL BE GALVANIZED STEEL, ¼-INCH MINIMUM DIAMETER FOR LENGTHS 36 INCHES OR LESS; ⅜-INCH MINIMUM DIAMETER FOR LENGTHS LONGER THAN 36 INCHES. 46.MANUAL VOLUME DAMPERS, STANDARD, STEEL, MANUAL VOLUME DAMPERS: STANDARD LEAKAGE RATING WITH LINKAGE OUTSIDE AIRSTREAM, SUITABLE FOR HORIZONTAL OR VERTICAL APPLICATIONS. FRAMES SHALL BE A HAT-SHAPED TYPE, GALVANIZED SHEET STEEL, MITERED AND WELDED CORNERS WITH FLANGES FOR ATTACHING TO WALLS. PROVIDE FRAMES FOR INSTALLING IN DUCTS. THE BLADES ARE TO BE MULTIPLE OR SINGLE BLADE OR PARALLEL THE BLADE AXLES SHALL BE GALVANIZED STEEL, DAMPERS IN DUCTS WITH PRESSURE CLASSES OF 3-INCH WG OR LESS SHALL HAVE AXLES FULL LENGTH OF DAMPER BLADES AND BEARINGS AT BOTH ENDS OF OPERATING SHAFT. 2.10.4 MANUAL BALANCING DAMPERS. 47.CONTROL DAMPERS, GENERAL REQUIREMENTS: USE PARALLEL BLADE CONFIGURATION FOR TWO-POSITION CONTROL. SEE DRAWINGS FOR SIZES. 48.CONSTRUCTION SHALL BE STANDARD STEEL. PROVIDE STANDARD LEAKAGE RATING WITH LINKAGE OUTSIDE AIRSTREAM, SUITABLE FOR HORIZONTAL OR VERTICAL APPLICATIONS. THE FRAMES SHALL BE HAT-SHAPED CHANNEL WITH INTEGRAL FLANGES. THE BLADES SHALL BE AIRFOIL, GALVANIZED STEEL WITH A PARALLEL BLADE CONFIGURATION. MATERIAL SHALL BE ASTM A 653 GALVANIZED STEEL. THE BLADE SEALS SHALL BE REPLACEABLE AND ARE TO BE MECHANICALLY ATTACHED EXTRUDED SILICONE, VINYL, OR PLASTIC COMPOSITE. THE JAMB SEALS ARE TO BE STAINLESS STEEL, OR COMPRESSION TYPE. THE AXLES SHALL BE MECHANICALLY ATTACHED TO BLADES. BEARINGS ARE TO BE STAINLESS STEEL MOUNTED IN THE FRAME. WHERE BLADE AXLES ARE INSTALLED IN VERTICAL POSITION, PROVIDE THRUST BEARINGS. THE LINKAGE SHALL BE CONCEALED IN FRAME AND CONSTRUCTED OF ALUMINUM AND PLATED OR STAINLESS STEEL WITH STAINLESS STEEL HARDWARE. THE DAMPERS AND ACTUATORS SHALL BE ACCESSIBLE FOR VISUAL INSPECTION AND SERVICE. DAMPER ACTUATORS SHALL OPERATE WITH DAMPERS WITH SUFFICIENT RESERVE POWER TO PROVIDE SMOOTH MODULATING ACTION OR TWO-POSITION ACTION AND PROPER SPEED OF RESPONSE AT VELOCITY AND PRESSURE CONDITIONS TO WHICH THE DAMPER IS SUBJECT TO. ACTUATORS SHALL PRODUCE SUFFICIENT POWER AND TORQUE TO CLOSE OFF AGAINST THE MAXIMUM SYSTEM PRESSURES ENCOUNTERED. ACTUATORS SHALL BE SIZED TO CLOSE OFF AGAINST THE FAN SHUTOFF PRESSURE AS A MINIMUM REQUIREMENT. PROVIDE ONE ACTUATOR FOR EACH DAMPER ASSEMBLY. MULTIPLE ACTUATORS REQUIRED TO DRIVE A SINGLE DAMPER ASSEMBLY SHALL OPERATE IN UNISON IF NEEDED. 49.FLANGE CONNECTIONS SHALL BE ADD-ON OR ROLL-FORMED, FACTORY-FABRICATED, SLIDE-ON TRANSVERSE FLANGE CONNECTORS, GASKETS, AND COMPONENTS, GALVANIZED STEEL, GAGE AND SHAPE TO MATCH CONNECTING DUCTWORK. 50.TURNING VANES SHALL COMPLY WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE”; FIGURES 4-3, “VANES AND VANE RUNNERS,” AND 4-4, “VANE SUPPORT IN ELBOWS.” VANE CONSTRUCTION SHALL BE SINGLE OR DOUBLE WALL. 51.DUCT-MOUNTED ACCESS DOORS PROVIDE IN ACCORDANCE WITH SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE”; FIGURES 7-2, “DUCT ACCESS DOORS AND PANELS.” DOOR: DOUBLE WALL, RECTANGULAR. GALVANIZED SHEET METAL WITH INSULATION FILL AND THICKNESS AS INDICATED FOR DUCT PRESSURE CLASS. HINGES AND LATCHES: 1-BY-1-INCH BUTT OR PIANO HINGE AND CAM LATCHES. FABRICATE DOORS AIRTIGHT AND SUITABLE FOR DUCT PRESSURE CLASS. FRAME SHALL BE GALVANIZED SHEET STEEL WITH BEND-OVER TABS AND FOAM GASKETS. 52.FLEXIBLE CONNECTORS SHALL BE FLAME-RETARDANT OR NONCOMBUSTIBLE FABRICS COMPLY WITH UL 181, CLASS 1. THE OUTDOOR SYSTEM, FLEXIBLE CONNECTORS SHALL BE FABRIC GLASS FABRIC DOUBLE COATED WITH WEATHERPROOF, SYNTHETIC RUBBER RESISTANT TO UV RAYS AND OZONE. 53.DUCT ACCESSORY INSTALLATION SHALL BE ACCORDING TO APPLICABLE DETAILS IN SMACNA’S “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE” FOR METAL DUCTS. USE GALVANIZED-STEEL ACCESSORIES IN GALVANIZED STEEL. INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS. WHERE DAMPERS ARE INSTALLED IN DUCTS HAVING DUCT LINER, INSTALL DAMPERS WITH HAT CHANNELS OF SAME DEPTH AS LINER, AND TERMINATE LINER WITH NOSING AT HAT CHANNEL. SEE DRAWINGS FOR SOME OF THE DAMPER LOCATIONS. HOWEVER DAMPERS WILL NEED TO BE PROVIDED AS REQUIRED IN THE SYSTEM TO BALANCE THE SYSTEM ADEQUATELY. DAMPERS ARE TO BE SET AT A FULLY OPEN POSITION BEFORE TESTING, ADJUSTING, AND BALANCING. INSTALL TEST HOLES AT FAN INLETS AND OUTLETS AND ELSEWHERE AS NEEDED FOR BALANCING. INSTALL DUCT ACCESS DOORS ON SIDES OF DUCTS TO ALLOW FOR INSPECTING, ADJUSTING, AND MAINTAINING ACCESSORIES AND EQUIPMENT AT THE FOLLOWING LOCATIONS: FIRE AND SMOKE DAMPERS LOCATIONS IF JOB REQUIRED! AS WELL AS CONTROL DAMPERS AREAS. DOORS ARE TO BE INSTALLED WITH SWING AGAINST DUCT STATIC PRESSURES. 54.INSTALL FLEXIBLE CONNECTORS TO CONNECT DUCTS TO EQUIPMENT. INSTALL DUCT TEST HOLES WHERE REQUIRED FOR TESTING AND BALANCING PURPOSES. SCALED FOR ORIGINAL DRAWING AT 22" X 34" ZM003 MADISON ARMORY 100% SUBMITTAL SAVED: 2021-08-24 16:44:06 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM001-003-21.038.00.dwg---- Project Manager: Territory Manager: Project Engineer: Drawn By: Approved By: Origination Date: ADAM ZIEGENFELDER 08/24/2021 WILLIAM LEWIS SCOTT DESANTI WILLIAM LEWIS STEVE TIBBALS REVISION DATENoBY PROJECT STATUS PROJECT NAMEP O Box 636, Provo UT, 84603Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.comThe use of these plans shall be restricted to the original project site for which they were prepared.Publications expressly limited to such use. Re-use, reproduction, or publication by any method in wholeor part is prohibited. drawings and designs remain the property of action target inc. without reservation.Action Target Inc. 2021 All Rights ReservedDRAWING NUMBER SHEET NAME SHEET NUMBER HVAC SPECIFICATIONS KEYED NOTES (SHEET ZM101.1)•• GENERAL NOTES (SHEET ZM101.1)SHEET NAMESHEET NUMBERSCALED FOR ORIGINAL DRAWING AT 22" X 34"ZM101.1MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 16:20:42 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM101.1-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedHVAC 25YD & 50YDRANGE PLANSCALE: 1/8" = 1'-0"HVAC - 25YD & 50YD RANGE PLAN KEYED NOTES (SHEET ZM102.1) GENERAL NOTES (SHEET ZM102.1)SHEET NAMESHEET NUMBERSCALED FOR ORIGINAL DRAWING AT 22" X 34"ZM102.1MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 13:59:25 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM102.1-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedHVAC 25YD & 50YDPENETRATIONPLANSCALE: 1/8" = 1'-0"HVAC - 25YD & 50YD PENETRATION PLAN KEYED NOTES (SHEET ZM103.1)•• GENERAL NOTES (SHEET ZM103.1)SHEET NAMESHEET NUMBERSCALED FOR ORIGINAL DRAWING AT 22" X 34"ZM103.1MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 14:51:27 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM103.1-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedHVAC 25YD & 50YDROOF PLANSCALE: 1/8" = 1'-0"HVAC - 25YD & 50YD ROOF PLAN KEYED NOTES (SHEET ZM301.1)••• GENERAL NOTES (SHEET ZM301.1)SHEET NAMESHEET NUMBERSCALED FOR ORIGINAL DRAWING AT 22" X 34"ZM301.1MADISON ARMORY100% SUBMITTALSAVED: 2021-08-25 10:58:11 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM301.1-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedHVAC 50YDRANGE SECTIONSCALE: 1/8" = 1'-0"HVAC - 50YD RANGE SECTION SCALED FOR ORIGINAL DRAWING AT 22" X 34"SHEET NUMBERSHEET NAMEZM501MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 14:54:46 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM501-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedAIRFLOWSCHEMATICPURGE SYSTEMAIR FLOW SCHEMATIC - 25YD & 50YD RANGES NOT TO SCALE1ZM501MAICTVFDAOBODPAISBIBUILDING DIFFERENTIAL PRESSUREDOOR STATUSTAIOUTDOOR TEMPERATUREPAIRANGE PRESSUREAORANGE PRESSURE SETPOINTMAICTVFDAOBOGAS HEAT HLAIE.A. 34,320 CFMEXHAUST FA(EF-1)17,160 CFMS.A.31,200 CFMSUPPLY FAN(MAU-1)31,200 CFMO.A. 31,200 CFMMBO(FB-1)DPHEPAFILTERDPBAG TYPEFILTERMERV 14AIAIAIANALOG INPUTESEND SWITCHHLHIGH LIMIT SWITCHVARIABLE FREQUENCY DRIVECTCURRENT TRANSFORMERBOBINARY OUTPUTVFDMMOTORIZED DAMPERDSPDUCT STATIC PRESSUREMAKE-UP AIR SCHEMATIC - RANGE BAYSEXHAUST AIR SCHEMATIC - RANGE BAYSAIBIBIBIBIESTAIPAIE.A. 34,320 CFM SCALED FOR ORIGINAL DRAWING AT 22" X 34"SHEET NUMBERSHEET NAMEZM502MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 14:54:46 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM501-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedLOW VOLTAGESCHEMATICPURGE SYSTEMCONTROL WIRING SCHEMATIC - PURGE SYSTEMEQUIPMENT LEGEND - BY ACTION TARGETITEMQTYDESCRIPTIONJB41WATERPROOF JUNCTION BOX - CONTAINS PRESSURE SENSORSS4DOOR PRESSURE SENSORTH1TEMPERATURE/HUMIDITY SENSORDP1DIFFERENTIAL PRESSURE UNITRCP1RANGE VENTILATION CONTROL PANEL CONNECTED TO MASTERCONTROL SCREENMCS1MASTER CONTROL SCREEN (W/ SMART ACCESS)MAU-VFD1VARIABLE FREQUENCY UNIT FOR THE MAKEUP AIR UNITEF-VFD1VARIABLE FREQUENCY UNIT FOR THE EXHAUST FANP1DUCT PRESSURE SENSOR KEYED NOTES (SHEET ZM502)RANGE ENTRANCE DOOR - SSIDE ENTRANCE DOOR - SSUPPLY TEMP - THSUPPLY DUCT PRESSURE - PMAU OUSIDE AIR TEMPOUSIDE AIR FILTEREVAP ENABLEOUTSIDE AIR DAMPERMAU HEAT CONTROL/ENABLE120V 15A INPUTFILTER RETURN BANK - DPSUPPLY VFD - MAUEXHAUST VFD - EFADJUSTABLE FREQUENCY DRIVE PROVIDEDBY ATI AND LOCATED INDOORS. VFD SHALL BEIN A TEMPERATURE CONTROLLED ANDACCESSIBLE LOCATIONADJUSTABLE FREQUENCY DRIVE PROVIDEDBY ATI AND LOCATED INDOORS. VFD SHALL BEIN A TEMPERATURE CONTROLLED ANDACCESSIBLE LOCATIONHVAC MASTER PANELPURGE VENTILATIONRCP10x10J-BOX10x10J-BOXATI SUPPLIEDJ-BOX (JB-4)4x4J-BOXDUCT MOUNTED1-18/41-18/42-18/42-18/63-18/44-18/42-18/63-18/41-18/62-18/41-18/61-18/42-RS-4851-CAT5E1-18/42-RS-4851-CAT5ESMOKE DETECTOR(BY OTHERS)1-18/4INTERNET IN from SMART RANGE AXIS (SRA)1-CAT5ETYP.TYP.PNEUMATIC TUBE TO SPACEADJACENT TO RANGE1/4"1/4"PNUEMATIC TUBE SCALED FOR ORIGINAL DRAWING AT 22" X 34"SHEET NUMBERSHEET NAMEZM601MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 16:43:50 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM601-603-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedMECHANICAL HVACSCHEDULES SCALED FOR ORIGINAL DRAWING AT 22" X 34"SHEET NUMBERSHEET NAMEZM602MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 16:43:50 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM601-603-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedMECHANICALDETAILSMANUAL BALANCING DAMPER ROUND6 38 IN. MAX.18 IN. DIAMETER20 GA.FRAMEAND BLADETHICKNESSNOTE:BASIS OF DESIGN: GREENHECK MBDR-50PRESSURE: UP TO 4 IN W.G.38 IN. SQ. LOCKINGMANUAL QUADRANTGALVANIZEDSTEELSYNTHETICSLEEVEAXLE BEARINGTYPICAL DUCTWORK45 DEGREE TAKE-OFFAIR FLOWAIR FLOWDUCT/PIPE ROOF CURB DETAILWITH RIDGE PEAK FOR WATER SHEDTYPICAL ROOF DUCT SUPPORTTYPICAL DUCT STRAP HANGERDUCT CONSTRUCTIONTYPICAL ROOF CURBTRAPEZE HANGER DETAILRADIAL DIFFUSER DETAIL (TYP.)FRONT VIEW4"18"4"24"28"24"18"24"24"48"12"TOP VIEW0.375"Ø MOUNTING HOLE(TYP-5)SIDE VIEWRIGHT18"Ø2"18"ØFILTER BANK INSTALLATION DETAIL (TYP.)25"36"DUCT TRANSITIONFROM RANGEDUCT TRANSITIONEXHAUST FAN SIDEMEDIUM EFFICIENCYFILTER SECTIONMERV 14HEPA FILTERSECTIONMERV 17DUCTWORKCONNECTINGTHE FILTER BANKTO THE EXHAUSTFAN SHALL BERATED AT AMINIMUM OF 8"WCSTATIC PRESSURE.CONCRETEPAD OR ROOF(BY OTHERS)EQUIPMENT RAILL/ARDEN MODEL SER-POR EQUIVALENT (TYP)CEILING REQUIREMENTS DETAIL8'-0"CONSTANT SLOPE CEILING ONLY (NO STEPS)SLOPE AS NEEDED DOWN TO STATIC FIRING LINE.INSTALL ALL RADIAL DIFFUSERSAT THE SAME HEIGHT. INSTALLJUST ABOVE DOOR JAMS ANDWINDOW JAMS. DO NOTINSTALL HIGHER THAN NEEDED.TYPICALLY 7'-0" MINIMUM.SAFETY CEILINGHEIGHT1'-6"7'-0"ACTION TARGETBALLISTIC SAFETYCEILING SCALED FOR ORIGINAL DRAWING AT 22" X 34"SHEET NUMBERSHEET NAMEZM603MADISON ARMORY100% SUBMITTALSAVED: 2021-08-24 16:43:50 BY: BILLY.LEWIS AT: Z:\_Projects\2021\21.038.00 - Madison Armory GR\Mechanical\ATI-ZM601-603-21.038.00.dwg DRAWING NUMBER----Project Manager:Territory Manager:Project Engineer:Drawn By:Approved By:Origination Date:ADAM ZIEGENFELDER08/24/2021WILLIAM LEWISSCOTT DESANTIWILLIAM LEWISSTEVE TIBBALSREVISIONDATENoBYPROJECT STATUSPROJECT NAMEP O Box 636, Provo UT, 84603 Office: (801) 377-8033 | Fax: (801) 377-8096 | www.ActionTarget.com The use of these plans shall be restricted to the original project site for which they were prepared. Publications expressly limited to such use. Re-use, reproduction, or publication by any method in whole or part is prohibited. drawings and designs remain the property of action target inc. without reservation. Action Target Inc. 2021 All Rights ReservedMECHANICALDETAILSPIPE HANGERSROOF PIPE SUPPORT - POLYMER BASETYPICAL GAS PIPING LB. TO OZ. CONNECTIONRCP PANEL DETAILDISPLAYRCPCOORDINATE LOCATIONWITH BUILDING OWNER.MUST BE LOCATED WITHIN300' OF RCP.RANGE VENTILATIONCONTROL PANEL. INSTALL INCONDITIONED SPACE WITHIN300' OF EQUIPMENT DISPLAY.FINISHED FLOORVENTILATION CONTROLPANEL (VCP).BY ACTION TARGET.24Hx20Wx8DTYPICAL PANELSIZE.(DETAIL 5)RCPPANELTROUGHCONDUIT & TROUGHBY ELECTRICALCONTRACTOR.CONTROLS120VVARIABLE FREQUENCY DRIVE DETAILMOUNT VFD TO WALLUSING HOLLOW WALLOR MASONRY ANCHORSTHE LOCATIONS OF THE VFD'S,RANGE VENTILATION CONTROLBOX AND RANGE VENTILATIONDISPLAY ARE TO BE DETERMINEDBY THE CUSTOMER OR GENERALCONTRACTOR.IT IS RECOMMENDED THAT THEVFD'S AND THE RANGEVENTILATION CONTROL BOX BEINSTALLED IN AN ELECTRICALROOM AND THE RANGEVENTILATION DISPLAY IN ANADJACENT RETAIL SPACE WHEREIT CAN BE EASILY SEEN ANDREADILY ACCESSIBLE.ACS-CP-AFINISHED FLOORMOUNT VFD ON WALLWHERE DIRECTED BYOWNER IN ACONDITIONED SPACEVARIABLE FREQUENCY DRIVE (VFD) DETAILVRD = VARIABLE FREQUENCY DRIVEE.C. = ELECTRICAL CONTRACTORSUPPLY ANDEXHAUST FAN VFDBY ACTION TARGETCONDUIT ROUTEDTO RANGE CONTROLPANEL (RCP). E.C.30.5H x 13.4W x15.7D DIMENSIONSARE FOR ONE OFTHE LARGESTDRIVE SIZES. SIZETBD.(DETAIL 3)NOTE:EACH VENTILATIONSYSTEM REQUIRESA VFD FOR THESUPPLY ANDEXHAUST FANS.HIGH VOLTAGE CONDUITAND TROUGH. BY E.C..FINISHED FLOORSUPPLYFANVFD4x4 J-BOXTYP.HIGH VOLTAGE TROUGH B.O.EXHAUSTFANVFDR-CER TYPEEQUIPMENT STAND DETAILROOF MOUNTED - R-CER TYPE EQUIP. STANDSUTILITY TYPE EXHAUST FAN DETAILFLEXIBLECONNECTIONTRANSITIONEXHAUSTDUCTGRAVITYBACKDRAFTDAMPERWEATHER-PROOFENCLOSURE OVERMOTOR SECTIONDUCT SUPPORTSAS NEEDEDMOUNT ON SEISMICALLYCAGED SPRINGVIBRATIONISOLATORSR-CER TYPEEQUIPMENT STAND(TYP.)MAKE-UP AIR UNIT CURB DIAGRAM