HomeMy WebLinkAboutSOIL DENSITY 4 - 19-00731 - The Grove at Thomson Farms PH2 - Hickory - 30 Unit Bldg 4In Place Density of Soils ASTM D2922 & D3017
Project Name:
Project Number:
Client:
Contractor:
Date:Tested By:
Time Start:Time End:
Instrument ID
Daily Standardization:MS:DS:
Test
Number
Depth: Elevation:% M:
Proctor:
% of
Proctor:
Test
Number
Test
Number
Test
Number
Test
Number
Test Location:
Elevation:
Material Type:
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Reviewed By:
Remarks:
Page 1 of 2
Depth:
Depth:
Depth:
Depth:
Depth:
Depth:
Pass Fail
Dry:
Wet:Test Location:
Material Type:
FailPass
FailPass
Pass Fail
FailPass
FailPass
FailPass
Test
Number
Test
Number
лйсͨтрйͨплмрϝϝϝͨωϕϔϔϋωϚϋϔύϘͨωϕϓнкймΎпйоΗΜϛϏϚϋкΛϏύψϟͥΒсмннл
Thompson Farms
20001
Stillwater Equity Partners
05/18/2020 F Pelton
3:45 6:45
867
1192 5177
12Bottom of Footing 5.011
132
98%
Approximately A.75 and 1.25 of Building 6.
Bottom of Footing
Pit Run
97%
132
5.969
128.3
136
95%
132
4.953
126
132.2
Pit Run
Bottom of Footing
Approximately A.5 and 2.5 of Building 6.
96%
132
5.466
127.1
134.1
Pit Run
Bottom of Footing
Approximately A.25 and 3.75 of Building 6.
97%
132
5.226
128.1
134.8
Pit Run
Bottom of Footing
Approximately A.75 and 3.75 of Building 6.
96%
132
5.152
127
133.6
Pit Run
Bottom of Footing
Approximately C.25 and 3.75 of Building 6.
95%
132
5.72
125
132.2
Pit Run
Bottom of Footing
Approximately C.75 and 3.7 of Building 6.
Digitally signed by Jacob P
Christensen
Date: 2020.05.19 11:43:53 -06'00'
12
10
12
12
12
12
1
129
135Approximately A.25 and 1.25 of Building 6.
Pit Run
5
6
7
2
3
4
Test
Number
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Proctor:
% of
Proctor:
% M:Elevation:
Wet:Test Location:
Material Type:
Dry:
Page 2 of 2
% of
Proctor:
Proctor:
% M:
Dry:
Wet:
Material Type:
Elevation:
Test Location:
Depth:
Depth:
Depth:
Depth:
Depth:
Depth:
Depth:
Depth:
Depth:
Depth:
FailPass
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Pass Fail
Test
Number
Test
Number
Test
Number
Test
Number
Test
Number
Test
Number
Test
Number
Test
Number
Test
Number
96%
132
4.701
126.2
132.2
Pit Run
Bottom of Footing
Approximately C.75 and 1.25 of Building 6.
132
99%
4.875
130.1
136.4
Pit Run
Bottom of Footing
Approximately C.25 and 1.25 of Building 6.
132
98%
4.525
128.9
134.8
Pit Run
Bottom of Footing
Approximately C.35 and 2.5 of Building 6.
12
12
12
8
9
10