HomeMy WebLinkAboutPLANS - 21-00667 - 277 Jill Dr - Solar PanelsJ
B
A
C
D
P
M
A
C
D
P
M
C
B
M
S
P
U
M
M
S
P
U
M
1
1
0
'
-
1
"
95'-6"
95'-6"
1
1
0
'
-
1
"
14'-8"
3
5
'
-
2
"
13'-3"
2
1
'
-
2
"
SCALE: 1/16" = 1'
C
O
V
E
R
P
A
G
E
S
I
T
E
P
L
A
N
L
A
Y
O
U
T
V
I
C
I
N
I
T
Y
M
A
P
DANI
E
L
M
O
N
C
A
Y
O
-
7
.
4
8
0
k
W
D
C
,
5
.
2
8
k
W
A
C
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
T
-
1
SHEET CATALOGINDEX NO.T-1M-1M-2E-1PL-1SS DESCRIPTIONCOVER PAGEMOUNTING DETAILSTRUCTURAL DETAILTHREE LINE DIAGRAMWARNING PLACARDSSPEC SHEET(S)SCOPE OF WORKGENERAL SYSTEM INFORMATION:SYSTEM SIZE:7480W DC, 5280W ACMODULES:(22)HANWHA Q.cells Q.peak duo BLK-G6+ 340WINVERTER:(22)ENPHASE IQ7-60-2-USHIGH TEMP: 33°C, LOW TEMP: -26°CAPPLICABLE CODES·FIRE CODE:IFC 2018·ENERGY CONSERVATION CODE:IECC 2018·BUILDING CODE:IBC 2018·RESIDENTIAL CODE:IRC 2018GENERAL NOTES1.MODULES ARE LISTED UNDER UL 1703 ANDCONFORM TO THE STANDARDS.2.INVERTERS ARE LISTED UNDER UL 1741 ANDCONFORM TO THE STANDARDS.3.DRAWINGS ARE DIAGRAMMATIC, INDICATINGGENERAL ARRANGEMENT OF THE PV SYSTEM ANDTHE ACTUAL SITE CONDITION MIGHT VARY.4.WORKING CLEARANCES AROUND THE NEW PVELECTRICAL EQUIPMENT WILL BE MAINTAINED INACCORDANCE WITH NEC 110.26.5.ALL GROUND WIRING CONNECTED TO THE MAINSERVICE GROUNDING IN MAIN SERVICE PANEL/SERVICE EQUIPMENT.6.ALL CONDUCTORS SHALL BE 600V, 75°CSTANDARD COPPER UNLESS OTHERWISE NOTED.7.WHEN REQUIRED, A LADDER SHALL BE IN PLACEFOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.8.THE SYSTEM WILL NOT BE INTERCONNECTED BYTHE CONTRACTOR UNTIL APPROVAL FROM THELOCAL JURISDICTION AND/OR THE UTILITY.9.ROOF ACCESS POINT SHALL BE LOCATED INAREAS THAT DO NOT REQUIRE THE PLACEMENTOF GROUND LADDERS OVER OPENINGS SUCH ASWINDOWS OR DOORS, AND LOCATED AT STRONGPOINTS OF BUILDING CONSTRUCTION WHERE THEACCESS POINT DOES NOT CONFLICT WITHOVERHEAD OBSTRUCTIONS SUCH AS TREES,WIRES OR SIGNS.10.PV ARRAY COMBINER/JUNCTION BOXPROVIDES TRANSITION FROM ARRAY WIRING TOCONDUIT WIRING ·ELECTRIC CODE:NEC 2017 (E) MAIN SERVICE PANEL,200ARATED (INSIDE GARAGE)
(
E
)
U
T
I
L
I
T
Y
M
E
T
E
R
P
H
O
T
O
V
O
L
T
A
I
C
A
R
R
A
Y
O
N
T
H
E
R
O
O
F
VISIBLE, LOCKABLE, LABELED AC DISCO
N
N
E
C
T
I
S
LOCATED WITHIN 10 FEET OF THE UTILI
T
Y
M
E
T
E
R
JILL DR
3
'
F
I
R
E
S
E
T
B
A
C
K
D
R
I
V
E
W
A
Y
(
N
)
V
I
S
I
B
L
E
,
L
O
C
A
B
L
E
A
N
D
L
A
B
E
L
L
E
D
A
C
D
I
S
C
O
N
N
E
C
T
W
I
T
H
I
N
1
0
'
O
F
U
T
I
L
I
T
Y
M
E
T
E
R
P
R
O
P
E
R
T
Y
L
I
N
E
(
N
)
P
R
O
D
U
C
T
I
O
N
M
E
T
E
R
(
N
)
E
N
P
H
A
S
E
C
O
M
B
I
N
E
R
P
A
N
E
L
W
I
T
H
E
N
V
O
Y
-
I
Q
M
E
T
E
R
1
8
"
F
I
R
E
S
E
T
B
A
C
K
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
M
-
1
SCALE: 3/32" = 1'-0"
M
O
U
N
T
I
N
G
D
E
T
A
I
L
INSTALLATION NOTES1.STRUCTURAL ROOF MEMBER LOCATIONS AREESTIMATED AND SHOULD BE LOCATED AND VERIFIEDBY THE CONTRACTOR WHEN LAG BOLT PENETRATIONOR MECHANICAL ATTACHMENT TO THE STRUCTURE ISREQUIRED.2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILLBE COMPLETED AND SEALED WITH APPROVED SEALANTPER CODE BY A LICENSED CONTRACTOR.3.LAGS MUST HAVE A MINIMUM 2.5" THREADEMBEDMENT INTO THE STRUCTURAL MEMBER.4.ALL PV RACKING ATTACHMENTS SHALL BESTAGGERED BY ROW BETWEEN THE ROOF FRAMINGMEMBERS AS NECESSARY.5.ROOF MOUNTED STANDARD RAIL REQUIRES ONETHERMAL EXPANSION GAP FOR EVERY RUN OF RAILGREATER THAN 40'.6.ALL CONDUCTORS AND CONDUITS ON THE ROOFSHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE(INCLUDING CABLES UNDERNEATH MODULES ANDRACKING).7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANYPLUMBING, MECHANICAL OR BUILDING ROOF VENTS.ROOF ACCESS PATHWAYS AND SETBACKS:1204.2.1 SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUPR-3BUILDINGS.SOLAR PHOTOVOLTAIC SYSTEMS FORGROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS1204.2.1.1 THROUGH 1204.2.1.3.EXCEPTIONS:1.THESE REQUIREMENTS SHALL NOT APPLY TOSTRUCTURES DESIGNED AND CONSTRUCTED INACCORDANCE WITH THE INTERNATIONAL RESIDENTIALCODE.2.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFSWITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITSHORIZONTAL OR LESS.1204.2.1.1 PATHWAYS TO RIDGE. NOT FEWER THANTWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATEROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWERTHAN ONE PATHWAY SHALL BE PROVIDED ON THESTREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACHROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOTFEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAYFROM LOWEST ROOF EDGE TO RIDGE SHALL BEPROVIDED ON THE SAME ROOF PLANE AS THEPHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANEOR STRADDLING THE SAME AND ADJACENT ROOFPLANES1204.2.1.2 SETBACKS AT RIDGE.FOR PHOTOVOLTAICARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLANVIEW TOTAL ROOF AREA,A SETBACK OF NOT LESS THAN 18 INCHES (457MM)WIDE IS REQUIRED ON BOTH SIDES OF AHORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYSOCCUPYING MORE THAN 33 PERCENT OF THE PLANVIEW TOTAL ROOF AREA, A SETBACK OF NOT LESSTHAN 36 INCHES (457 MM) WIDE IS REQUIRED ONBOTH SIDES OF A HORIZONTAL RIDGE.1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS.PANELS AND MODULES INSTALLED ON GROUP R-3BUILDINGS SHALL NOT BE PLACED ON THE PORTION OFA ROOF THAT IS BELOW AN EMERGENCY ESCAPE ANDRESCUE OPENING. A PATHWAY OF NOT LESS THAN 36INCHES (914 MM) WIDE SHALL BE PROVIDED TO THEEMERGENCY ESCAPE AND RESCUE OPENING1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE.WHERE AN AUTOMATIC SPRINKLER SYSTEM ISINSTALLED WITHIN THE DWELLING IN ACCORDANCEWITH SECTION 903.3.1.3, SETBACKS AT THE RIDGESHALL CONFORM TO ONE OF THE FOLLOWING:1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENTOR LESS OF THE PLAN VIEW TOTAL ROOF AREA, ASETBACK OF NOT LESS THAN 18 INCHES (457 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTALRIDGE.2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, ASETBACK OF NOT LESS THAN 36 INCHES (914 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTALRIDGE
A
E
R
I
A
L
V
I
E
W
SITE
I
N
F
O
R
M
A
T
I
O
N
-
W
I
N
D
S
P
E
E
D
:
1
1
5
M
P
H
A
N
D
S
N
O
W
L
O
A
D
:
N
/
A
P
S
F
SR. NOARRAYTILTAZIMUTHNO.
O
F
MOD
U
L
E
S
A
R
R
A
Y
A
R
E
A
(
S
Q
.
F
T
.
)
R
O
O
F
T
Y
P
E
A
T
T
A
C
H
M
E
N
T
R
O
O
F
E
X
P
O
S
U
R
E
F
R
A
M
E
T
Y
P
E
F
R
A
M
E
S
I
Z
E
F
R
A
M
E
S
P
A
C
I
N
G
M
A
X
R
A
I
L
S
P
A
N
O
V
E
R
H
A
N
G
MP-0120°180°1
2
2
3
1
.
7
5
C
O
M
P
O
S
I
T
I
O
N
S
H
I
N
G
L
E
I
R
O
N
R
I
D
G
E
F
L
A
S
H
F
O
O
T
2
A
T
T
I
C
T
R
U
S
S
2
"
x
8
"
2
'
-
0
"
6
'
-
0
"
2
'
-
0
"
MP-0220°180°1
0
1
9
3
.
1
2
C
O
M
P
O
S
I
T
I
O
N
S
H
I
N
G
L
E
I
R
O
N
R
I
D
G
E
F
L
A
S
H
F
O
O
T
2
A
T
T
I
C
T
R
U
S
S
2
"
x
8
"
2
'
-
0
"
6
'
-
0
"
2
'
-
0
"
NOTE:PENETRATIONS ARE STAGGERED
A
R
R
A
Y
M
P
-
0
2
A
R
R
A
Y
M
P
-
0
1
2"X8" TRUSS@ 2'-0" O.C. SPACING
(
N
)
I
R
O
N
R
I
D
G
E
X
R
-
1
0
0
R
A
I
L
(
3
6
)
I
R
O
N
R
I
D
G
E
F
L
A
S
H
F
O
O
T
2
A
T
T
A
C
H
M
E
N
T
@
7
2
"
O
.
C
.
6
'
6
"
S
T
R
U
C
T
U
R
A
L
D
E
T
A
I
L
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
M
-
2
AT
T
A
C
H
M
E
N
T
D
E
T
A
I
L
M
O
D
U
L
E
S
D
A
T
A
H
A
N
W
H
A
Q
.
c
e
l
l
s
Q
.
p
e
a
k
d
u
o
B
L
K
-
G
6
+
3
4
0
W
M
O
D
U
L
E
D
I
M
S
6
8
.
5
"
x
4
0
.
6
"
x
1
.
5
7
"
G
R
O
U
N
D
I
N
G
E
N
D
/
M
I
D
C
L
A
M
P
(
N
)
I
R
O
N
R
I
D
G
E
X
R
-
1
0
0
R
A
I
L
F
L
A
S
H
F
O
O
T
2
A
T
T
A
C
H
M
E
N
T
5
/
1
6
"
x
3
"
S
S
L
A
G
B
O
L
T
W
I
T
H
M
I
N
2
1
2
"
T
H
R
E
A
D
E
M
B
E
D
M
E
N
T
,
S
E
A
L
E
D
P
E
N
E
T
R
A
T
I
O
N
SEE (2/PV-5) FORENLARGED VIEW
(
E
)
C
O
M
P
S
H
I
N
G
L
E
R
O
O
F
(N
)
S
O
L
A
R
M
O
D
U
L
E
(
E
)
2
"
x
8
"
T
R
U
S
S
@
2
'
-
0
"
O
.
C
I
R
O
N
R
I
D
G
E
X
R
-
1
0
0
R
A
I
L
(
N
)
S
O
L
A
R
M
O
D
U
L
E
(
E
)
C
O
M
P
S
H
I
N
G
L
E
R
O
O
F
(
E
)
2
"
x
8
"
T
R
U
S
S
@
2
'
-
0
"
O
.
C
1ATTACHMENT DETAILM-2SCALE: NTSM-2SCALE: NTS ATTACHMENT DETAIL (Top view)M-2SCALE: NTS 2
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
E
-
1
T
H
R
E
E
L
I
N
E
D
I
A
G
R
A
M
THREE LINE DIAGRAM: DC S
Y
S
T
E
M
S
I
Z
E
-
7
4
8
0
W
,
A
C
S
Y
S
T
E
M
S
I
Z
E
-
5
2
8
0
W
INVERTER SPECIFICATIONSMODELPOWER RATINGMAX OUTPUT CURRENTCEC WEIGHTED EFFICIENCYMAX INPUT CURRENTMAX DC VOLTAGE ENPHASEIQ7-60-2-US(240V)235W-350W1A97%15A PER STRING48V MAX MODULE SPECIFICAT
I
O
N
MODELMODULE POWER @ STCOPEN CIRCUIT VOLTAGE:VocMAX POWER VOLTAGE:VmpSHORT CIRCUIT VOLTAGE:IscMAX POWER CURRENT:Imp HAN
W
H
A
Q
.
c
e
l
l
s
Q
.
p
e
a
k
duo
B
L
K
-
G
6
+
3
4
0
W
3
4
0
W
4
0
.
6
6
V
3
3
.
9
4
V
1
0
.
5
2
A
1
0
.
0
2
A
O
C
P
D
C
A
L
C
U
L
A
T
I
O
N
S
:
I
N
V
E
R
T
E
R
O
V
E
R
C
U
R
R
E
N
T
P
R
O
T
E
C
T
I
O
N
=
I
N
V
E
R
T
E
R
O
/
P
I
X
C
O
N
T
I
N
U
O
U
S
L
O
A
D
(
1
.
2
5
)
=
2
2
x
1
.
2
5
x
1
.
0
0
=
2
7
.
5
0
A
=
>
P
V
B
R
E
A
K
E
R
=
3
0
A
T
O
T
A
L
R
E
Q
U
I
R
E
D
P
V
B
R
E
A
K
E
R
S
I
Z
E
/
F
U
S
E
D
S
I
Z
E
=
>
3
0
A
P
V
B
R
E
A
K
E
R
EL
E
C
T
R
I
C
A
L
C
A
L
C
U
L
A
T
I
O
N
S
DC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS>>· REQUIRED CONDUCTOR AMPACITY: 125% PER 690.8(A)(1) X Isc(A) X #OFPARALLEL STRINGS = MAX CURRENT PER 690.8(A)(1) X 125% PER690.8(B)(2)(a)=MAX CURRENT PER 690.8(B)(2)(a)· CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATEFACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <DERATED CONDUCTOR AMPACITYAC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >>· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OFINVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A)· CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATEFACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <DERATED CONDUCTOR AMPACITY
A
C
W
I
R
E
C
A
L
C
U
L
A
T
I
O
N
S
:
-
M
A
T
E
R
I
A
L
:
C
O
P
P
E
R
&
T
E
M
P
E
R
A
T
U
R
E
R
A
T
I
N
G
:
9
0
°
C
TAG ID
R
E
Q
U
I
R
E
D
C
O
N
D
U
C
T
O
R
A
M
P
A
C
I
T
Y
A
C
W
I
R
E
C
A
L
C
U
L
A
T
I
O
N
S
:
-
M
A
T
E
R
I
A
L
:
C
O
P
P
E
R
&
T
E
M
P
E
R
A
T
U
R
E
R
A
T
I
N
G
:
9
0
°
C
TAG ID
R
E
Q
U
I
R
E
D
C
O
N
D
U
C
T
O
R
A
M
P
A
C
I
T
Y
C
O
R
R
E
C
T
E
D
A
M
P
A
C
I
T
Y
C
A
L
C
U
L
A
T
I
O
N
6
2
.
4
A
D
E
R
A
T
E
D
C
O
N
D
U
C
T
O
R
A
M
P
A
C
I
T
Y
C
H
E
C
K
<
C
O
R
R
E
C
T
E
D
A
M
P
A
C
I
T
Y
C
A
L
C
U
L
A
T
I
O
N
<
E
L
E
C
T
R
I
C
A
L
N
O
T
E
S
1
.
C
O
N
D
U
C
T
O
R
S
E
X
P
O
S
E
D
T
O
S
U
N
L
I
G
H
T
S
H
A
L
L
B
E
L
I
S
T
E
D
A
S
S
U
N
L
I
G
H
T
R
E
S
I
S
T
A
N
T
P
E
R
N
E
C
3
1
0
.
1
0
(
D
)
.
2
.
C
O
N
D
U
C
T
O
R
S
E
X
P
O
S
E
D
T
O
W
E
T
L
O
C
A
T
I
O
N
S
S
H
A
L
L
B
E
S
U
I
T
A
B
L
E
F
O
R
U
S
E
I
N
W
E
T
L
O
C
A
T
I
O
N
S
P
E
R
N
E
C
3
1
0
.
1
0
(
C
)
.
3
.
M
A
X
I
M
U
M
D
C
/
A
C
V
O
L
T
A
G
E
D
R
O
P
S
H
A
L
L
B
E
N
O
M
O
R
E
T
H
A
N
2
%
.
4
.
A
L
L
C
O
N
D
U
C
T
O
R
S
S
H
A
L
L
B
E
I
N
C
O
N
D
U
I
T
U
N
L
E
S
S
O
T
H
E
R
W
I
S
E
N
O
T
E
D
.
5
.
B
R
E
A
K
E
R
/
F
U
S
E
S
I
Z
E
S
C
O
N
F
O
R
M
S
T
O
N
E
C
2
4
0
.
6
C
O
D
E
S
E
C
T
I
O
N
.
6
.
A
C
G
R
O
U
N
D
I
N
G
E
L
E
C
T
R
O
D
E
C
O
N
D
U
C
T
O
R
S
I
Z
E
D
P
E
R
N
E
C
2
5
0
.
6
6
.
7
.
A
M
B
I
E
N
T
T
E
M
P
E
R
A
T
U
R
E
C
O
R
R
E
C
T
I
O
N
F
A
C
T
O
R
I
S
B
A
S
E
D
O
N
N
E
C
6
9
0
.
3
1
(
C
)
.
8
.
A
M
B
I
E
N
T
T
E
M
P
E
R
A
T
U
R
E
A
D
J
U
S
T
M
E
N
T
F
A
C
T
O
R
I
S
B
A
S
E
D
O
N
N
E
C
3
1
0
.
1
5
(
B
)
(
2
)
.
9
.
M
A
X
.
S
Y
S
T
E
M
V
O
L
T
A
G
E
C
O
R
R
E
C
T
I
O
N
I
S
P
E
R
N
E
C
6
9
0
.
7
.
1
0
.
C
O
N
D
U
C
T
O
R
S
A
R
E
S
I
Z
E
D
P
E
R
W
I
R
E
A
M
P
A
C
I
T
Y
T
A
B
L
E
N
E
C
3
1
0
.
1
5
(
B
)
(
1
6
)
.
11.00
1
2
X
X
1
=
1
5
A
3
0
0
.
7
1
1
2
.
0
0
X
1
.
2
5
=
X
X
0
.
8
=
1
7
.
0
4
A
22
1
.
0
0
X
=
1
.
2
5
X
=
2
7
.
5
A
6
5
X
0
.
9
6
X
1
=
2 & 3
1
5
A
1
7
.
0
4
A
2
7
.
5
A
6
2
.
4
A
2
2
M
A
I
N
P
A
N
E
L
R
A
T
I
N
G
:
2
0
0
A
,
M
A
I
N
R
E
A
K
E
R
R
A
T
I
N
G
:
2
0
0
A
(
E
)
M
A
I
N
B
R
E
A
K
E
R
T
O
H
O
U
S
E
2
4
0
V
,
2
0
0
A
/
2
P
(
T
O
P
F
E
D
)
N
L
2
L
1
T
O
U
T
I
L
I
T
Y
G
R
I
D
B
I
-
D
I
R
E
C
T
I
O
N
A
L
U
T
I
L
I
T
Y
M
E
T
E
R
1
-
P
H
A
S
E
,
3
-
W
,
1
2
0
V
/
2
4
0
V
G
E
C
G
E
X
I
S
T
I
N
G
G
R
O
U
N
D
I
N
G
E
L
E
C
T
R
O
D
E
S
Y
S
T
E
M
T
O
E
A
R
T
H
R
E
F
.
N
E
C
2
5
0
.
5
2
,
2
5
0
.
5
3
(
A
)
M
N
S
U
P
P
L
Y
S
I
D
E
T
A
P
(
E
)
G
L
1
L
2
N
3
(
E
)
M
A
I
N
S
E
R
V
I
C
E
P
A
N
E
L
2
0
0
A
R
A
T
E
D
,
2
4
0
V
M
E
T
E
R
N
O
.
:
4
6
4
0
2
4
0
7
D
E
R
A
T
E
D
C
O
N
D
U
C
T
O
R
A
M
P
A
C
I
T
Y
C
H
E
C
K
P
V
P
R
O
D
U
C
T
I
O
N
M
E
T
E
R
N
E
M
A
3
R
,
U
L
L
I
S
T
E
D
M
L
O
A
D
L
I
N
E
G
L
1
L
2
N
G
L
1
L
2
N
3
A
C
D
I
S
C
O
N
N
E
C
T
:
V
I
S
I
B
L
E
,
L
O
C
K
A
B
L
E
,
L
A
B
E
L
E
D
6
0
A
F
U
S
E
D
,
(
2
)
3
0
A
F
U
S
E
S
,
2
4
0
V
N
E
M
A
3
R
,
U
L
L
I
S
T
E
D
G
N
JUNCTION BOX600 V, NEMA 3UL LISTED (2) ENPHASE Q CABLES20A/
2
P
L2 L1 1 12 MICROINVERTERS IN BRANCH CIRCUIT 1 ENPHASE C
O
M
B
I
N
E
R
P
A
N
E
L
W
I
T
H
ENV
O
Y
I
Q
M
E
T
E
R
,
(2) 20A / 240V
A
C
C
I
R
C
U
I
T
B
R
E
A
K
E
R
S
,
NEMA 3R, U
L
L
I
S
T
E
D
,
1
2
5
A
R
A
T
E
D
10 MICROINVERTERS IN BRANCH CIRCUIT 2G
E
N
V
O
Y
I
Q
(REVEN
U
E
G
R
A
D
E
M
E
T
E
R
)
4 10
A
/
2
P
20A/
2
P
L2 L1 HANWHA Q.CELLS Q.PEAKDUO BLK-G6+ 340WENPHASE IQ7-60-2-USMICROINVERTERS ONE UNDEREACH PANEL(240V)
2
P
E
R
M
A
N
U
F
A
C
T
U
R
E
R
S
P
E
C
I
F
I
C
A
T
I
O
N
S
,
E
I
T
H
E
R
1
0
A
O
R
1
5
A
B
R
E
A
K
E
R
I
S
S
U
I
T
A
B
L
E
F
O
R
U
S
E
CONDUIT SCHEDULETAG ID123CONDUIT SIZE1" EMT OR EQUIV(2) 6 AWG THHN/THWN-2 CONDUCTOR(4) 12AWG THHN/THWN-2 NEUTRALNONE(1) 6 AWG THHN/THWN-2
G
R
O
U
N
D
1" EMT OR EQUIV4
(
1
)
1
0
A
W
G
T
H
H
N
/
T
H
W
N
-
2
(
1
)
1
0
A
W
G
T
H
H
N
/
T
H
W
N
-
2
(
1
)
1
0
A
W
G
T
H
H
N
/
T
H
W
N
-
2
(
1
)
6
A
W
G
B
A
R
E
C
U
3/4" EMT OR EQUIV(2) 6 AWG THHN/THWN-2(1) 6 AWG THHN/THWN-2
J
B
A
C
D
P
M
A
C
D
P
M
C
B
M
S
P
U
M
M
S
P
U
M
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
P
L
-
1
W
A
R
N
I
N
G
P
L
A
C
A
R
D
A
L
L
P
L
A
C
A
R
D
S
S
H
A
L
L
B
E
O
F
W
E
A
T
H
E
R
P
R
O
O
F
C
O
N
S
T
R
U
C
T
I
O
N
,
B
A
C
K
G
R
O
U
N
D
O
N
A
L
L
P
L
A
C
A
R
D
S
S
H
A
L
L
B
E
R
E
D
W
I
T
H
W
H
I
T
E
L
E
T
T
E
R
I
N
G
U
.
O
.
N
.
P
L
A
C
A
R
D
S
H
A
L
L
B
E
M
O
U
N
T
E
D
D
I
R
E
C
T
L
Y
O
N
T
H
E
E
X
I
S
T
I
N
G
U
T
I
L
I
T
Y
E
L
E
C
T
R
I
C
A
L
S
E
R
V
I
C
E
.
F
A
S
T
E
N
E
R
S
A
P
P
R
O
V
E
D
B
Y
T
H
E
L
O
C
A
L
J
U
R
I
S
D
I
C
T
I
O
N
P
O
W
E
R
T
O
T
H
I
S
B
U
I
L
D
I
N
G
I
S
A
L
S
O
S
U
P
P
L
I
E
D
F
R
O
M
T
H
E
F
O
L
L
O
W
I
N
G
S
O
U
R
C
E
S
W
I
T
H
D
I
S
C
O
N
N
E
C
T
S
L
O
C
A
T
E
D
A
S
S
H
O
W
N
W
A
R
N
I
N
G
:
!
(
E
)
U
T
I
L
I
T
Y
M
E
T
E
R
SOLAR PV SYSTEM EQUIPPE
D
WITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN THE PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYPLACED ON INVERTER SOLAR ELECTRIC PV PANELS WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THIS PHOTOVOLTAICSYSTEM ARE UNGROUNDED AND MAY BEENERGIZEDLABEL LOCATIONDC DISCONNECT,INVERTER[PER CODE: NEC 690.41)][To be used when inverter is ungrounded]WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENT WHEN SOLARMODULES ARE EXPOSED TO SUNLIGHTLABEL LOCATIONAC DISCONNECT,POINT OF INTERCONNECTION[PER CODE: NEC 690.13(B)] WARNINGELECTRIC SHOCK HAZARDTERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITIONLABEL LOCATIONAC DISCONNECT,POINT OF INTERCONNECTION[PER CODE: NEC 690.13(B)]WARNING-ELECTRIC SHOCK HAZARDNO USER SERVICEABLE PARTS INSIDECONTACT AUTHORIZED SERVICEPROVIDE FOR ASSISTANCELABEL LOCATIONINVERTER, JUNCTION BOXES(ROOF),AC DISCONNECT[PER CODE: NEC 690.13]WARNING:PHOTOVOLTAICPOWER SOURCELABEL LOCATIONCONDUIT, COMBINER BOX[PER CODE: NEC690.31(G)(3)]CAUTION: SOLAR ELE
C
T
R
I
C
SYSTEM CONNECTE
D
LABEL LOCATIONWEATHER RESISTANT MATERIAL, DURABL
E
A
D
H
E
S
D
I
V
E
,
UL969 AS STANDARD TO WEATHER RATIN
G
(
U
L
L
I
S
T
I
N
G
OF MARKINGS NOT REQUIRED), MIN 38" L
E
T
T
E
R
H
E
I
G
H
T
ARIAL OR SIMILAR FONT NON-BOLD,PLAC
E
D
W
I
T
H
I
N
THE MAIN SERVICE DISCONNECT,PLACED
O
N
T
H
E
OUTSIDE OF THE COVER WHEN DISCONN
E
C
T
I
S
OPERATED WITH THE SERVICE PANEL CL
O
S
E
D
.
(PER CODE: NEC690.15 ,690.13(B))RAPID SHUTDOWNSWITCH FOR SOLAR PVSYSTEMLABEL LOCATIONINVERTER[PER CODE: NEC 690.56(C)(3)]PHOTOVOLTAIC SYSTEM AC DISCONNECT S
W
I
T
C
H
RATED AC OPERATING CURRENTAC NOMINAL OPERATING VOLTAGELABEL LOCATIONAC DISCONNECT , POINT OF INTERCONNE
C
T
I
O
N
[PER CODE: NEC 690.54]WARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVER-CURRENT DEVICELABEL LOCATIONPOINT OF INTERCONNECTION(PER CODE: NEC 705.12(b)(2)(3)(b)[ Not Required if Panel board is rated not less than sum ofampere ratings of all overcurrent devices supplying it]CAUTION: SOLA
R
C
I
R
C
U
I
T
LABEL LOCATIONMARKINGS PLACED ON ALL INTERIOR AND
E
X
T
E
R
I
O
R
D
C
C
O
N
D
U
I
T
,
RACEWAYS, ENCLOSURES AND CABLE ASS
E
M
B
L
E
S
A
T
L
E
A
S
T
E
V
E
R
Y
10 FT, AT TURNS AND ABOVE/BELOW PEN
E
T
R
A
T
I
O
N
S
A
N
D
A
L
L
COMBINER/JUNCTION BOXES.(PER CODE: IFC605.11.1.4)SOLAR DISCON
N
E
C
T
LABEL LOCATIONDISCONNECT, POINT OF INTERCONNECTI
O
N
[PER CODE: NEC690.13(B)]WARNINGDUAL POWER SOURCE SECONDSOURCE IS PHOTOVOLTAICSYSTEMLABEL LOCATIONPOINT OF INTERCONNECTION[PER CODE: NEC705.12(D)(4)]27.5240A
M
P
S
A
C
V
A
C
!!!!
(
N
)
A
C
D
I
S
C
O
N
N
E
C
T
(
N
)
C
O
M
B
I
N
E
R
B
O
X
(
N
)
P
R
O
D
U
C
T
I
O
N
M
E
T
E
R
S
O
L
A
R
P
H
O
T
O
V
O
L
T
A
I
C
R
O
O
F
M
O
U
N
T
E
D
(
E
)
M
A
I
N
S
E
R
V
I
C
E
P
A
N
E
L
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
1
S
P
E
C
S
H
E
E
T
M
O
D
U
L
E
S
P
E
C
S
H
E
E
T
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
2
S
P
E
C
S
H
E
E
T
I
N
V
E
R
T
E
R
S
P
E
C
S
H
E
E
T
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
3
S
P
E
C
S
H
E
E
T
O
P
T
I
M
I
Z
E
R
S
P
E
C
S
H
E
E
T
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
4
S
P
E
C
S
H
E
E
T
O
P
T
I
M
I
Z
E
R
S
P
E
C
S
H
E
E
T
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
5
S
P
E
C
S
H
E
E
T
M
O
U
N
T
S
P
E
C
S
H
E
E
T
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
6
S
P
E
C
S
H
E
E
T
M
O
U
N
T
S
P
E
C
S
H
E
E
T
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
7
S
P
E
C
S
H
E
E
T
M
O
U
N
T
S
P
E
C
S
H
E
E
T
C
U
S
T
O
M
E
R
I
N
F
O
R
M
A
T
I
O
N
N
A
M
E
:
D
A
N
I
E
L
M
O
N
C
A
Y
O
A
D
D
R
E
S
S
:
4
3
.
8
2
0
4
0
7
,
-
1
1
1
.
8
0
3
9
3
9
A
P
N
:
R
P
R
H
N
D
S
2
0
6
0
0
5
0
D
E
S
I
G
N
E
R
/
C
H
E
C
K
E
D
D
A
T
E
:
0
8
/
1
2
/
2
0
2
1
S
C
A
L
E
:
A
S
N
O
T
E
D
P
A
P
E
R
S
I
Z
E
:
1
7
"
X
1
1
"
R
E
V
:
A
A
H
J
:
R
E
X
B
U
R
G
C
I
T
Y
U
T
I
L
I
T
Y
:
R
O
C
K
Y
M
O
U
N
T
A
I
N
P
O
W
E
R
P
R
N
N
U
M
B
E
R
:
N
A
2
7
7
J
I
L
L
D
R
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
,
U
S
A
B
Y
:
S
A
T
S
S
-
8
S
P
E
C
S
H
E
E
T
M
O
U
N
T
S
P
E
C
S
H
E
E
T