Loading...
HomeMy WebLinkAboutLETTER - 92-00009 - Albertsons - New BuildingARCHITECTS/PLANNERS ..._amu � � ■ BUJ rLr_iUf 200 N 6th Boise., Idaho 8370 208-343-463 FAX 208-43-1 SSR January 9, 1992 Terry Leishman Building Department City of Rexburg 12 North Center Rexburg, ID 83440 RE: Albertson's No. 171 NEC Teton River and E. 2nd N. Project No. 91073 Dear Mr. Leishman Four copies of construction pians for the above referenced pRUJECT ars hereby submitted for PLAN REVIEW. Two (2) copies of the project manuals including specifications and sons regvrt) are included. Two (2) sets of the documents have been "wet signed" by the architect and engineers. and fourth copies of plans (unsigned) are intended for review by tie Fire DeDartmen agencies requiring pans. If additianai codes are required please contact us. Following is the list of personnel associated with the project., ARCHITECT91 : STRUCTURAL ENG'R: MECHANICAL ENG'R: ELECTRICAL ENG'R: FIRE PROTEC'TION: The third ts or hLI-1 HERBERT J. WINTERS REX HARRISON DEAN McKELLIP JACK TAYLOR JAMES WICKING dna gnone number for eachproject design team member ars fisted an the cover Pages of the groj ect manuals and �.ri the attached sets of plans on Sheet No. 1.0-1, Partial. Site Pian, center of the page. SOILS ENGINEER and GEOTECHNICAL DATA: (See the SOILS REPORT included in the Project Manual - Specifications, following Section 2200 - Earthwork). GENERAL COMMENTS41 1. The two official review sets each consast of one manual, calculations,and buildingConstruction plans. Both official sets are "wetsigned" Y p b each disci 1xne 2. This submittal consists of the construction of a single -story retail grocery store. The building has been designated ALBERTSON'S as depicted on the partial Site Plan P 1.0.1. I Occupancy Classification is B-2. Minimum Tnf�+nnotreir.+;r.., .� TrT ,.r ,�---- __.. _,�-�, .....)"La� ��.t �„f lib 111 -IN, rue spnx� nered.3. Data for the above project has been reviewed 0 for conformance with the followin codes FEDERAL REGISTER 28 CFR PART 36 UNIFORM BUILDING CODE: UNIFORM MECHAN,1CAL CODE: UATIFORM PLUMBING CODE: UNIFORM FIRE CODE; NATIO' NAL ELECTRICAL CODE: ADA (implementing Title III of the American's with Disabilities Act -199 1 UBC 1941 UMC 1991 UPC 1991 UFC 1991 NEC 4. En .gineered Sprinkler Drawings (prepared by an approved sprinkler contractor) shall be submitted tot he Building Department A FTER THE BID and prior to construction. 5. Building Setbacks: 1111t ecu: Yard Varies to parcel Zine at dock, exceeds 60' at remaining length of wall, Right** Exceeds 60' to property line. Front: Exceeds G0' yard. Left: 0' to parcel line along wail common with retail Shops. Exterior walls are rated as follows* Left Wall: 4 her gratec�on (g� parcel i ne & 2 hr where openings are permitted, Other Walls* Unprotected @ non-combustible non-bearing & 2 hr � non-combustible bearing wa11s. 6. Maximum Building Area; Designated type of construction is Type III -N, for 11B-2 Occupancy. UBC Table No. 5-C allow 12:,000 S.F. of building area. Partial Site Plan (1,0-1 of the drawings) shows 2 side yard separation. Vie will use 2 - side yard separation to obtain max" area increases. UBC S{ec. 506(a)l provides an allowable area increase based on 2 -side yard separation as follows: The rate of increase for separation on 2 sides in 1. 25 % for each foot by which the minimum width exceeds 20 feet., The yard width exceeds 6o,6 Therefore 50' minus 20' equals 4D' (anI Iica Ie), allowing 4Q�' x .4 � 2 5 = SQ % yr 1 + 0.5 — 1.5 multiplier, 12 ,000 s.f. x 1.5 (area multiplier) = 18,000 s.f. PERMITTED 18,2000 s.f. x 3 (sprinkler (per Sec. 506. (c)) . .f. Increase) = 54,000 sALLOWABLE INCREASE 54,000 s.f, permitted > 40,241 s.f. provided. OK 7. Building Area,. Mr. Terry Leishman January 9, 1992 Page 3 Mezzanine Retail & Support Area Mechanical Mezzanine TOTAL Canopy/overhangs 8, Occupant Load by Use: Use Assembly Areas Kitchin -Commercial M e,ch. Equip. R () 0 M Offices Store -Retail Sales Stock Roy Corriclorq MS Room No. 202 108, 110, 112, 114, 115, 116, 118). 127 120, 206, 212, 213, 107, 207, 209,211 103, 104, 105, 121, Entrances 101, 102, and Stairs 2031210 Coolers, Freezers Restrooms Not Used Total Building Area Total Occupant Load ill) 124, 129, 132, 11_9, 9. Exits Required: 106, 109 122, 208 1 34, 201 113, 117, 123 , 125, 126, 128, 135 133, 204, 130, 131, Overall 1,422 37,134 1.685 40,241 1, 705 s.f.(not included) S.FJFactor 350 at 15 2,655 at 200 1, 894 at 300 68 1 at 100 24,430 at 30 5,090 at 300 1,691 at 100 3,102 at 100 205 348 at 100 4 0,241 Sq. Ft. Occ. ioad mmmw�w.� (23) 13 6 7 814 17 17 (3 1)* (4)* WA NUMBER: UBC See., 3303.(a)requires not less than three exits for occupant loads of 501 to 1000. The occupant load is designated as 874 (see part 8, above). Four exists are provided. WIDTH: 874 (occupants)/ 50 = 17.48, say 17.5 LF required Width of exiting pr0V1ded: Opening No. 02 - 3 n ft Fv;f av, , TOTAL Width Provided 17.5 11, required < 194,5 Lfa provided. 03 - & 3.5 .6 ft. Ex -it 19 No. 1 04 - 3.5 ft. Exit No. 2 OS - 3.0 ft. Exit No. 2 20 - 3.05 ft. Exit No., 3 23 - 300 ft. Exit No. 4 19.5 ft. As directed bY Rose Bagley, City Clerk, this package has been forwarded without payment of the plate check fee. She indicate the amount would be established upon your receipt of this package. Once we have been advised of the amount, Payment will be promptly issued. Mr. Terry Leishman January 9, 1992 Page 4 This completes our initial plan review submittal.Please provide a written response and/orapproval at your earliest cvnveni�nc�e. �f you have any questions, do not hesitate to calf ,(Collect) Respectfully submitted, CSHQA Architects/Planners. Gene Shaffer, AIA GS; ms cc: Jeremy Jeffers Attachments: 4 leis of Plans Z Project Manuals (including soils 2 Structural Calculations