HomeMy WebLinkAboutCODE CHECK - 92-00003 - Walmart - New BuildingWALLACE ENGINEERING • STRUCTURAL CONSULTANTS
201 W. FIFTH SUITE 200 TULSA, OKLAHOMA 74103 (918) 584.5858
PROJECT: Wal-Mart Rexbu-rg, Idaho
DATE: 9145!91
TIME: 10:15
BY PHONE: 3C
CONVERSATION WITH: Terry Leishman
Bulldl'ng Inspector
. CODE: 1991 Uniform Buildl*ng Code
b. LOCAL AMENDMENTS: None
2. a. MINIMUM ROOF LIVE LOAD: 40
D. carsVUrvu tilVuvV LUAU: 4 d v sf
r
s. CAN GROUND SNOW LOAD BE
(NIA if pg c 20 psf)
3. a. WIND SPEED: 8 0 mph
b. MINIMUM WIND LOAD: Per Code
4. a. SEISMIC ZONE: 3
PSf
,BY VISIT: BY OTHER:
Rexburg CV HaI�
REDUCED ACCORDING TO CODE: No
i. EFFECTIVE PEAK VELOCITY - RELATED ACCELERATION:
(NIA if seismic zine o, or pg c 30 psf)
ii.
CAN WE REDUCE THE DESIGN SNOW LOAD FOR USE IN SEI
IF YES, 8Y WHAT PERCENTAGE: % (75D/o MAX.)
(NIA ff seismic zone 0, or pg r 30 psf)
5. FROST DEPTH J MINIMUM BEARING DEPTH: 3 6 i n ,
SISIIC NALYSIS: No
rwase natty Glens P. Kustera
at Wallace Engineering (g18 _ 584 _ 5858) ff any of the above information is incorrect.
REMARKS:
COPIES. To.
Terry Leishman
Building inspector
P.O. Bax 245
Rexburg, ID 83440
PHONE N4.: (208) 359-3020
T
Frank Pampalone
BS W Architects
1400 S. Boston, Sete 300
Tulsa, OK 74119
EIEC:
4-r
Glenn P. Kustera