HomeMy WebLinkAboutCONCRETE TEST 42 - The Grove at Thomson FarmsFile name:
20001SB08162021YK
81220A64-DEE0-483E-A019-D633F6C7D149 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
11.0
Project Name:
The Grove
Test Location:
Sidewalk at The Grove
Client:
Stillwater Equity Partners
Admixtures:
0
Ticket Number:
1
Contractor:
Kevin Virgin
Supplier:
Walters Ready Mix, Inc
Mix Number:
526FCITY
Date:
7/19/2021
Cylinder Log #:
469
Field Test Results:
Set #:
1
Slump
(inches):
7.0
Slump
Maximum
(in):
Entrained Air
(%):
5.10
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
76
Ambient
Temperature
(°F):
64
Unit Weight
(PCF):
138.55
Tested By:
A. Montes
Date:
7/19/2021
Picked Up By:
D. Rykowski
Date:
7/19/2021
Time:
9:45 AM
Max, Min Temperature
64,73
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 7/26/2021 4.00 12.56 34525 2748.81 3,000.00 Type 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 8/16/2021 4.00 12.6 54,435.0 4320.2 3,000.0 Type 2
C 28 8/16/2021 4.00 12.6 52,920.0 4200.0 3,000.0 Type 2
D 28 8/16/2021 4.00 12.6 54,615.0 4334.5 3,000.0 Type 2
Second Break Average:
4284
Date:
08/16/2021
Reviewed By:
E. Vail
Signature: