Loading...
HomeMy WebLinkAboutCONCRETE TEST 42 - The Grove at Thomson FarmsFile name: 20001SB08162021YK 81220A64-DEE0-483E-A019-D633F6C7D149 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20001 Cumulative Test Load Amount: 11.0 Project Name: The Grove Test Location: Sidewalk at The Grove Client: Stillwater Equity Partners Admixtures: 0 Ticket Number: 1 Contractor: Kevin Virgin Supplier: Walters Ready Mix, Inc Mix Number: 526FCITY Date: 7/19/2021 Cylinder Log #: 469 Field Test Results: Set #: 1 Slump (inches): 7.0 Slump Maximum (in): Entrained Air (%): 5.10 Entrained Air Spec. (%): Concrete Temperature (°F): 76 Ambient Temperature (°F): 64 Unit Weight (PCF): 138.55 Tested By: A. Montes Date: 7/19/2021 Picked Up By: D. Rykowski Date: 7/19/2021 Time: 9:45 AM Max, Min Temperature 64,73 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/26/2021 4.00 12.56 34525 2748.81 3,000.00 Type 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/16/2021 4.00 12.6 54,435.0 4320.2 3,000.0 Type 2 C 28 8/16/2021 4.00 12.6 52,920.0 4200.0 3,000.0 Type 2 D 28 8/16/2021 4.00 12.6 54,615.0 4334.5 3,000.0 Type 2 Second Break Average: 4284 Date: 08/16/2021 Reviewed By: E. Vail Signature: