HomeMy WebLinkAboutPLAN REVIEW - 96-00009 - Cal Ranch Stores - Addition11 ffL%'EXBURG MADISON COUNTY FIRE DEPAR9rMENT P a 0 . Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1994 Unl*form Fire Cade P1 an Review Building Name, GAL Ranch Stare Building Address.:404 Narth 2nd Easy Stories: 1 Occupancy Classif'cation: M New Construction Floor Area: -5.,760 Plan Date: 03-11-96 Review Date: 03-25-96 Type of cons t ruction: ii -N Existing Floor Area : lg 400 total of 24 �1*1 1).Required Fire Flo w (A�apen�.i x I I I -A) 3 250 p, m Comments@_ -Up to 75% reduction for -automat ic sprinkler-- system not less than- 1.,500 a p m e 0 2)mWater Supply (Article 9, Section 903) Required: Fire Hydrant Locations. 8-31 2nc� Fi�� Hydrant Flows, 0 Fire. Flow Test Locatioll. Fire Flow Supplied By: Other Approved Water Source: Water SuPPly Acceptable.** Yes --..X No Fire Hydrant Location Ac.. eptabl e : yes X No Wader SuPPlY Comments; 8-37 3r Yes K Na 3. }Fire Apparatus Acce sRoads �tic�.e !I Section 902} Required: Yes- X No but E.& 4th Na Acceptable,* Width* 30-- feet Length: Pull throuQh Surface : As haI t Turning Radiu�s : �3�31�� Grade ; t- kay �ehicl e Vertical Clearance.* 0�a Turn Around: NZA___. IA Flan Review Page 2 Complete Road Acceptable: Yes Comments; 4 } .Access Roars and Water Supply, including Fire Hydrants Are Required To Be Installed And Mads Serviceable Prior To And wring Time Of Construction Comments 0 (Article 9 Section 901.3) Yes X No 5 ) . Instal lation Of Portable Fire Extinguisher (Arti:cle 10 Sec 3 -on 1002) Requireds, Yes X No---- Location Acceptable: YesNo Type Provided acceptable: Yes No-- comments: Size and IA r, o rn Q n * r% ^ 4- m" 1,.,L ., v. -w . 0-1- U.M dans, 6).Automatic Fire Extingu ishingI SYStems;(Article 10 Sect'vn 1003 Required: YesX Na Type Of System Being Installed; Sec,. 1003. 2. 7 over 12,000 scuare fppt Not shown on the lens, Sprinkler System Monitoring Required. (Artisc1� 1� Section 1 43.3) Required; Yes.,, -,,X No Comments: If over 100 heads 7)wStandpipes (Article 10 Section 1Q04) Required: Yes No X Type Required: Comments: Not requi red i f_bu`1dJL,n has a s rinkler system 8} -Ventilating Hood And Duct Fire Xtinguishing System (Article 10 SectiOn 100 red Type Being Provided: Yes N 0 X Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4) Yes N oX Portable Fire Extinguisher shown (Article 10 section 1p06.2.?} Yes..--. No X Comments : No ,cook �,ng Plan Review Page 3 g } *Fire Alarm Systems (Artic3. e 10 Section 1007 ) Required: Yes�„ div X fiype Of System Required t Manual Automatic,Both Pr Type Of SSystemBeing Provided: Manual A ic Bath Components Of System Shawn: Smoke Detectors Heat Manual PuII Station Sounding Devices.......--. -M. Visual Detectors Devi ces 4EMPOPED0106� Door Holders � Duct Detectors Flow Alarm Sprinkler Valve Monitoring Fire Alarm �ys�emwmmftfto� Acceptable: Yes No, 10 ) - Other Correct' ions That Are Required By Special Occupancy Conditions: Additivnal exitsneedto be added. Exit throu storeroom is not allowed. Plans As Submitted Are Acceptable: Yes Ido X the Plans Checked By: Dee OwensDat�:0 96 Please furnish comments back to th lan reviewer in the tallowing manner: Written comments. New additional in,formation. Plans.; Showinq