HomeMy WebLinkAboutCONCRETE TEST 41 - The Grove at Thomson FarmsFile name:
20001SB08132021ES
0202D8ED-FE63-4AFC-A641-BB23ACCFE718 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
14.8
Project Name:
The Grove
Test Location:
South sidewalk of buildings 6 and 5
Client:
Stillwater Equity Partners
Admixtures:
Ticket Number:
1
Contractor:
Kelvin Virgin Construction
Supplier:
Walters Ready Mix
Mix Number:
526F CITY
Date:
7/16/2021
Cylinder Log #:
460
Field Test Results:
Set #:
1
Slump
(inches):
3.8
Slump
Maximum
(in):
Entrained Air
(%):
4.20
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
72
Ambient
Temperature
(°F):
60
Unit Weight
(PCF):
141.20
Tested By:
Y. Kabwika
Date:
7/16/2021
Picked Up By:
Yannick Kabwika
Date:
7/16/2021
Time:
2:15 PM
Max, Min Temperature
82.5; 49.1
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 7/23/2021 4.00 12.56 42620 3393.31 3,500.00 Type 1
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 8/13/2021 4.00 12.6 58,965.0 4679.8 3,500.0 Type 1
C 28 8/13/2021 4.00 12.6 62,105.0 4929.0 3,500.0 Type 2
D 28 8/13/2021 4.00 12.6 60,450.0 4797.6 3,500.0 Type 1
Second Break Average:
4801
Date:
08/13/2021
Reviewed By:
E. Vail
Signature: