Loading...
HomeMy WebLinkAboutCONCRETE TEST 41 - The Grove at Thomson FarmsFile name: 20001SB08132021ES 0202D8ED-FE63-4AFC-A641-BB23ACCFE718 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20001 Cumulative Test Load Amount: 14.8 Project Name: The Grove Test Location: South sidewalk of buildings 6 and 5 Client: Stillwater Equity Partners Admixtures: Ticket Number: 1 Contractor: Kelvin Virgin Construction Supplier: Walters Ready Mix Mix Number: 526F CITY Date: 7/16/2021 Cylinder Log #: 460 Field Test Results: Set #: 1 Slump (inches): 3.8 Slump Maximum (in): Entrained Air (%): 4.20 Entrained Air Spec. (%): Concrete Temperature (°F): 72 Ambient Temperature (°F): 60 Unit Weight (PCF): 141.20 Tested By: Y. Kabwika Date: 7/16/2021 Picked Up By: Yannick Kabwika Date: 7/16/2021 Time: 2:15 PM Max, Min Temperature 82.5; 49.1 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/23/2021 4.00 12.56 42620 3393.31 3,500.00 Type 1 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/13/2021 4.00 12.6 58,965.0 4679.8 3,500.0 Type 1 C 28 8/13/2021 4.00 12.6 62,105.0 4929.0 3,500.0 Type 2 D 28 8/13/2021 4.00 12.6 60,450.0 4797.6 3,500.0 Type 1 Second Break Average: 4801 Date: 08/13/2021 Reviewed By: E. Vail Signature: