Loading...
HomeMy WebLinkAboutCONCRETE TEST 9 - 21-00216 - Valley Agronomics - Maintenance ShopProject Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength 5,495 PSI Valley Agronomics Valley Agronomics 1820 20058 18553 11 of 170 MP 322, MAE 90 E. Jenkins 10/14/2020 9:15 AM 4.75 4.5 64 44 428A 428E 428C 428B 428D 4 4 4 4 10/21/20 11/11/20 11/11/20 11/11/20 52,890 67,835 69,775 69,625 2 4,0004,207 5,396 5,550 5,538 Digitally signed by Jacob Christensen Date: 2020.11.11 10:20:01 -07'00' 12.57 Walters Ready Mix Near Grid line6/A. First lift. 7 28 28 28 H 12.57 12.57 12.57 NA 1 of 2 D. Aust 10/15/2020 8AM 1 3 2