HomeMy WebLinkAboutCONCRETE TEST 6 - 21-00216 - Valley Agronomics - Maintenance ShopProject Name:
Client:
Mix Number:
Project Number:
Ticket Number:
Load Amount:
Admixtures:
Tested By:
Date and Time:
Compressive Strength of Concrete Test Specimens
Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511)
Slump (Inches):
Entrained Air (%):
Concrete Temperature:
Ambient Temperature:
Test Results:Minimum:Maximum:
Cylinder #
Lab Test Data: (ASTM C39, C42, C617, and C1231)
Break Age
Cylinder
Diameter (in)
Area
(in² )
Break
Date
Maximum Load
(lbs)
Break
Type
Compressive
Strength (psi)Required 28 day
Strength (psi)
°F
°F
Reviewed By:
Supplier:
Test Location:
Unit Weight (PCF):Set # :
Cylinders Picked Up By: Date and Time:
Hi / Low Temperatures
Remarks:
28-day Average Strength
5,133 PSI
Valley Agronomics
Valley Agronomics
1820
20058
18237
20 of 245 yards
MP 322, Maae 90
E. Jenkins
10/02/2020 9:30 AM
4
4
64
57
407A
407E
407C
407B
407D
4
4
4
4
10/09/20
10/30/20
10/30/20
10/30/20
57,060
64,765
64,640
64,160
2 4,0004,539
5,152
5,142
5,104
Digitally signed by Jacob
Christensen
Date: 2020.10.30 08:30:25 -06'00'
12.57
Walters Ready Mix
Near Grid E7 Footing
7
28
28
28
H
12.57
12.57
12.57
The contractor was informed of results. And chose to
continue the pour since there was no spec for the
concrete.
137.6 1 of 2
E. Jenkins 10/05/2020 2:00 PM
2
2
2