HomeMy WebLinkAboutCONCRETE TEST 3 - 21-00216 - Valley Agronomics - Maintenance ShopFile name:
20058SB03302021TP
14647B3F-0CEA-4B5A-BE0E-3D5E5592C164 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20058
Cumulative Test Load Amount:
9.0
Project Name:
Valley Ag
Test Location:
West building interior slab
Client:
Valley Ag
Admixtures:
N/A
Ticket Number:
20365
Contractor:
Gary Jones
Supplier:
Walter's
Mix Number:
1720
Date:
3/2/2021
Cylinder Log #:
63
Field Test Results:
Set #:
1
Slump
(inches):
6.0
Slump
Maximum
(in):
Entrained Air
(%):
1.00
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
62
Ambient
Temperature
(°F):
9
Unit Weight
(PCF):
143.1
Tested By:
W. Moffat
Date:
3/2/2021
Picked Up By:
T Paules
Date:
3/2/2021
Time:
10:19 AM
Max, Min Temperature
O
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 3/9/2021 4 12.56 52895 4211.39 4,000.00 Type 3
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 3/30/2021 4.0 12.6 68,805.0 5460.7 4,000.0 Type 1
C 28 3/30/2021 4.0 12.6 67,100.0 5325.4 4,000.0 Type 2
D 28 3/30/2021 4.0 12.6 64,710.0 5135.7 4,000.0 Type 2
Second Break Average:
5307
Date:
03/30/2021
Reviewed By:
S.Thompson
Signature: