Loading...
HomeMy WebLinkAboutCONCRETE TEST 2 - 21-00216 - Valley Agronomics - Maintenance ShopFile name: 20058SB03192021TP 5F20B1B9-9EF6-477D-8295-0F5CBA189482 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20058 Cumulative Test Load Amount: 9.0 Project Name: Valley Ag Test Location: North wall Client: Valley Ag Admixtures: N/A Ticket Number: 20292 Contractor: Gary Jones Construction Supplier: Walters Mix Number: 1820 Date: 2/19/2021 Cylinder Log #: 51 Field Test Results: Set #: 1 Slump (inches): 5.5 Slump Maximum (in): Entrained Air (%): 5.50 Entrained Air Spec. (%): Concrete Temperature (°F): 65 Ambient Temperature (°F): 27 Unit Weight (PCF): 34.34 Remarks: Tested By: W. Moffat Date: 2/19/2021 Time Tested: 51 Picked Up By: S.Thompson Date: 2/19/2021 Time: 10:20 AM Max, Min Temperature 120.5/51.8 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/26/2021 4 12.56 43,595.00 3470.94 4,000.00 Type 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 3/19/2021 4.0 12.6 55,335.0 4391.7 4,000.0 Type 1 C 28 3/19/2021 4.0 12.6 51,100.0 4055.6 4,000.0 Type 2 D 28 3/19/2021 4.0 12.6 56,425.0 4478.2 4,000.0 Type 2 Second Break Average: 4309 Reviewed By: S.Thompson Signature: Date: File name: 20058SB03192021TP 5F20B1B9-9EF6-477D-8295-0F5CBA189482 2 03/19/2021