Loading...
HomeMy WebLinkAboutCONCRETE TEST 12 - 21-00216 - Valley Agronomics - Maintenance ShopProject Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength 4,292 PSI Valley Agronomics Valley Agronomics 1820 20058 18888 7.5 of 15 yds MP 322, MAE 90 E Jenkins 10/27/2020 2:00 PM 5.5 4.8 66 35 465A 465E 465C 465B 465D 4 4 4 4 11/03/20 11/24/20 11/24/20 11/24/20 44,140 56,870 52,895 52,085 2 4,0003,511 4,524 4,208 4,143 Digitally signed by Jacob Christensen Date: 2020.11.24 14:10:46 -07'00' 12.57 Walters Ready Mix Mass footing. off SE corner of Addition 7 28 28 28 H 12.57 12.57 12.57 NA 1 of 1 T. Falls 10/28/2020 3 5 5