Loading...
HomeMy WebLinkAboutCONCRETE TEST - 21-00216 - Valley Agronomics - Maintenance ShopFile name: 20058SB03162021TP BF4FEE93-3E46-46BC-8198-9B9CA69376DB 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20058 Cumulative Test Load Amount: 15.0 Project Name: Valley Ag Test Location: Fittings on West side of building. Client: Valley Ag Admixtures: Ticket Number: 20252 Contractor: Gary Jones Construction Supplier: Walter's Ready Mix Mix Number: 1820 Date: 2/16/2021 Cylinder Log #: 46 Field Test Results: Set #: 1 Slump (inches): 5.0 Slump Maximum (in): Entrained Air (%): 6.80 Entrained Air Spec. (%): Concrete Temperature (°F): 56 Ambient Temperature (°F): 35 Unit Weight (PCF): 141 Remarks: Tested By: D. Aust Date: 2/16/2021 Time Tested: 46 Picked Up By: T paules Date: 2/16/2021 Time: 8:58 AM Max, Min Temperature Max 114.4 min 31.7 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/23/2021 4 12.56 50,460.00 4017.52 4000 Type 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 3/16/2021 4.0 12.6 59,700.0 4738.1 4,000.0 Type 1 C 28 3/16/2021 4.0 12.6 60,905.0 4833.7 4,000.0 Type 2 D 28 3/16/2021 4.0 12.6 63,205.0 5016.3 4,000.0 Type 2 Second Break Average: 4863 Reviewed By: S.Thompson Signature: Date: File name: 20058SB03162021TP BF4FEE93-3E46-46BC-8198-9B9CA69376DB 2 03/16/2021