Loading...
HomeMy WebLinkAboutRESCHECK - 21-00522 - 1127 Larch Dr - New SFRGenerated by REScheck-Web Software Compliance Certificate Project Fitzgerald ICF Energy Code:2018 IECC Location:Rexburg, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:2,193 ft2 Glazing Area 16% Climate Zone:6 (8693 HDD) Permit Date:2021-08-05T06:00:00.000Z Construction Site: 1127 Larch DR Rexburg, ID 83440 Owner/Agent:Designer/Contractor: Matthew Astin H&M Astin Homes LLC 469 Linden Ave Rexburg, ID 83440 605-890-3057 msastin@gmail.com 21-00522Permit Number: Compliance: Passes using UA trade-off 0.2% Better Than Code Maximum UA:447 Your UA:446 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Ceiling: Flat Ceiling or Scissor Truss 2,764 40.0 0.0 0.029 0.026 80 72 Wall: Wood Frame, 16" o.c.733 21.0 0.0 0.057 0.045 31 24 Door: Glass Door (over 50% glazing)42 0.290 0.300 12 13 Window: Vinyl Frame 12 0.270 0.300 3 4 Window 1: Vinyl Frame 12 0.270 0.300 3 4 Window 2: Vinyl Frame 25 0.270 0.300 7 8 Window 3: Vinyl Frame 25 0.270 0.300 7 8 Window 4: Vinyl Frame 25 0.270 0.300 7 8 Window 5: Vinyl Frame 27 0.270 0.300 7 8 Window 6: Vinyl Frame 27 0.270 0.300 7 8 Wall 1: Wood Frame, 16" o.c.356 21.0 0.0 0.057 0.045 18 14 Window 7: Vinyl Frame 10 0.270 0.300 3 3 Window 7 Copy: Vinyl Frame 10 0.270 0.300 3 3 Window: Vinyl Frame 16 0.270 0.300 4 5 Wall 2: Wood Frame, 16" o.c.198 21.0 0.0 0.057 0.045 9 7 Project Title: Fitzgerald ICF Data filename:Page 1 of 2 08/05/21Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Door 1: Solid Door (under 50% glazing)21 0.290 0.300 6 6 Door 1 Copy: Solid Door (under 50% glazing)21 0.290 0.300 6 6 Wall 3: Wood Frame, 16" o.c.84 21.0 0.0 0.057 0.045 5 4 Wall 4: Wood Frame, 16" o.c.149 21.0 0.0 0.057 0.045 6 5 Door 2: Glass Door (over 50% glazing)21 0.270 0.300 6 6 Window: Vinyl Frame 6 0.270 0.300 2 2 Window 8 Copy: Vinyl Frame 18 0.270 0.300 5 5 Wall 5: Wood Frame, 16" o.c.102 21.0 0.0 0.057 0.045 6 5 Wall 6: Wood Frame, 16" o.c.149 21.0 0.0 0.057 0.045 7 6 Window 8: Vinyl Frame 27 0.270 0.300 7 8 Wall 7: Wood Frame, 16" o.c.507 21.0 0.0 0.057 0.045 26 21 Window 9: Wood Frame 12 0.270 0.300 3 4 Window 9 Copy: Wood Frame 12 0.270 0.300 3 4 Window 9 Copy: Wood Frame 12 0.270 0.300 3 4 Window 9 Copy Copy: Wood Frame 12 0.270 0.300 3 4 Floor: Slab-On-Grade (Unheated) Insulation depth: 4.0'350 22.0 0.430 0.480 151 168 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Fitzgerald ICF Data filename:Page 2 of 2 08/05/21Report date: