HomeMy WebLinkAboutFIRE PLAN REVIEW - 97-00001 - Sears - Retail Stores�.
.m�
19 9 4 Una,fo�a
Pian R
Building Name
REXBURG MADI SON COUNTY FIRE DEPAR-*N
jW
Fire Code
P.O. Box 280
26 North Center
Idaho 83440
359-3010
ENTRAL
Building Address 310 NORTH -.-SECOND
Plan Date: JANUARY 19.97
Review Date JANUARY 13F 1997
Stories : ONE Type of '
Construction : II -NR
Occupancy ClasSificatign: M Existing Floor a:
New Construction Floor Area&& 82 6 SQ10Feet
8246 SQ. FEET
Required Fire Flow {Appendix
III -A):2000 GPM/ Two hours
Comments
2 - Water supply (Article
Fire Hydrant Location: Se
Fire Hydrant Flows
9, Section
conal East
Fire Flow Test Location_
Fire Flaw Supplied Hy
Other Approved Water Source
Water Supp1y Acceptable.- Yes
4
903) Required: YES
and KFC
Fire Hydrant Location Acceptable: Yes
Water Supply Comments : Fire Hydrant is required
`Lhe South is developed on a minimum of a 6-i.nch
when property to
suPply li-ne .
Plan Review
Page 2
3.)Fire Apparatus Access Roads
Require ves
(Article 9 Section 902)
Accep �ab1e : Width OKAY Length OKAY Surface OKAY
burning Radius OKAY Grade OKAY Vehicle Vertical
Clearance OKAY 'urn Arounds OKAY
Complete Road Acceptab? e OKAY Corn-ments
4}.Access Roads and Water Supply,
Including Fire Hydrants Are
Required Tn Be Installed And, Made Serviceable Prior To find During
Time Cif
Comments
Construction.Article 9 Section 901.3)
YES
5)4Installation of Portable "ire Extinguisher (Article
1002) Required: Yes Location Accept�b�e: � IOWN
Type Provided Acceptable. UNKNOWN
10 Section
Comments: FIRE EXTINGUISHER PLACEMENT, SIZE, AND TYPE NOT SHOWN.
NEEDS TO BE SPECIFIED,,
6) .Automatic Fire
Required-, No
Extinguishing Systems- (Article 10 Section 1003
Type Of System Being Ins�alled
Sprinkler System Monitoring Required (Article 10 Section 1003.3)
Reciui wed : No CommeP, 9
Plan
Page
Review
3
7}.E3 tandpzpes
Type Required;
Comment s
8j,Ven"Lilating
Section 1006,2)
r a
(ArLicle 10 Section 1004)
Hood And Duct Fire
Required: No
Type Being Provided
Automatic Fuel Shutoff Shown
NOT REQUIRED
10
Comments .
9 ) .Fire Alarm
Required:
Required: No
Extinguishing System Article 10
(Article 10 Section 1006.2.4)
Systems (Article 10 Section -1007)
Type Of System Required: Manual Automatic Both
Type Of System Being Provided.* Manual
�.�xtomatic Both
Gamponents Of System SSmoke Detectars_-- Heat Uetector�
Manual Pull Station._ Sounding Devices
Viso I Devices
Door Holders Duct Detectors Flow Alarm. Sprinkler Valve
�anitc�;ing Fire Alarm Sys- 0
tem Acceptable 6 N/A
Spec3fied:
10)*Other Corrections That Need To Be
FIRE EXTINGUISHERS NEED TO HE ADDRESSED AS TO PLACEMENT,TYPE
AND SIZE.
Plan Review
Page 4
IF SERVICE WORK ON INTERNAL COMBUSTION ENGINESDONE IN THE BUILDING THERE ARE DTF IS GOING TO BE
ADDRESSED. WILL SERVICEtn7ORK
RENTREQUIREMENTS TO BE
DONE ON THE PREMISES?
Plans Submitted Are Acceptable: No
Plans Checked By CHRIS HUSKINSON
Date JAN. 13, 199
.1 in
Piease furnish COMMents back to the, �eviewer the following
manner: Written Comments