HomeMy WebLinkAboutPLANS - 98-00034 - Horkley's Exxon Station - Canopy�c' n" 1997 U.B.C. DATA OCCUPANCY GROUP ........... S-3 CONSTRUCTION TYPE ........... II N OCCUPANCY LOAD FACTOR ........N.A. SEPARATION ..... SEE SITE PLAN AND SEC. 311.2.3.2 AND TABLE 5 A USE ..... CANOPY OVER GASOLINE PUMPS AREA . . . . . I .....q .....1976 Sq. Ft. FRAMING PLAN W10x22 PURLINS SCALE: 3/32"=1'-0" W16x31 BEAM 0 •_q• 13'-10� 13'-10j" 13'-103 13'-10r 13'-10� '_q• 7,, " DECK PANEL a ING TYP. w J V io TS 12x12x1/4 0 COLUMN c ❑ ❑ ❑ ❑ ❑ 4R\ 6" CONC SLAB `(12) EA. L.S.I. FIXTURES L N L J CONCRETE FOOTING REINFORCED PATH W6x6 8/8 WWF 4'-6"x5'-0" HIGH WITH 12" LAP OR Q4 BAR 0 1�—n O.C. VERT, ON 5'-0"0 AND 9'FiE�i�� ❑ ❑ ❑ ❑ ❑ ❑ HORIZONTAL 4QD s SECTION/ELEVATION LIGHTING SCHEME SCALE: 1/8"=1'-0" W �� SCALE: 3/32"=1'-O" s O APPROVED Z.. ✓ TgTF Of \aP ^gib D TE 9M ®•'M®(i $2155 BUILDING INSPECTOR P 1119% Z O 7 J W Z L Z O V Lu z cc 00 Xx W xa Wp z N — c 6 J W= S cc in H O W I- ca w 4 n 12'-0" 26'-0" 26'-0" 12'-0" 0 i N WIOx22 X -BRACING o _ M I 3 3 WIOx22 F 5'-6" S0. TS 12x12x1/4 --� FOOTING I COLUMN WIOx22 L L -J L J M I I I I W1Ox22 1997 U.B.C. DATA OCCUPANCY GROUP ........... S-3 CONSTRUCTION TYPE ........... II N OCCUPANCY LOAD FACTOR ........N.A. SEPARATION ..... SEE SITE PLAN AND SEC. 311.2.3.2 AND TABLE 5 A USE ..... CANOPY OVER GASOLINE PUMPS AREA . . . . . I .....q .....1976 Sq. Ft. FRAMING PLAN W10x22 PURLINS SCALE: 3/32"=1'-0" W16x31 BEAM 0 •_q• 13'-10� 13'-10j" 13'-103 13'-10r 13'-10� '_q• 7,, " DECK PANEL a ING TYP. w J V io TS 12x12x1/4 0 COLUMN c ❑ ❑ ❑ ❑ ❑ 4R\ 6" CONC SLAB `(12) EA. L.S.I. FIXTURES L N L J CONCRETE FOOTING REINFORCED PATH W6x6 8/8 WWF 4'-6"x5'-0" HIGH WITH 12" LAP OR Q4 BAR 0 1�—n O.C. VERT, ON 5'-0"0 AND 9'FiE�i�� ❑ ❑ ❑ ❑ ❑ ❑ HORIZONTAL 4QD s SECTION/ELEVATION LIGHTING SCHEME SCALE: 1/8"=1'-0" W �� SCALE: 3/32"=1'-O" s O APPROVED Z.. ✓ TgTF Of \aP ^gib D TE 9M ®•'M®(i $2155 BUILDING INSPECTOR P 1119% Z O 7 J W Z L Z O V Lu z cc 00 Xx W xa Wp z N — c 6 J W= S cc in H O W I- ca w 4 n p �-- ATE MFS .:®• PP�® BUILDING INSPECTOR #12 TEK a 1/8 M CONN. #12 TEK < +/9 TYV. CONN. #12 TEK @ 16" 0. C. 1"xt"x1/8" ANGLE 1"xi'xt/8" ANGLE STRUCTURAL NOTES: 4'-0" MAX. SPACING #12 TEK ®i6" O.C. 4'-0" MAX. SPACING 1-1/2"x1-1/2"x16 GA._z- GENERAL GALV. ANGLE CONTINUOUS e n 1- +/s1. I-1/2"x1-1/2"x16 GA. v The contractor shall verify all conditions and dimensions GALV. ANGLE CONTINUOUS at the site. PURLIN #12 TEK 2. Observation visits to the site by the design engineer shall COMPOSITE FASCIA SCREW (TYP.) neither be construed as inspection nor approval of m PANEL COMPOSITE FASCIA construction. d PANEL 3. During and after construction, builder and/or owner shall Fes- '� keep loads on the structure within limits of design loads. p 4. Typical details and sections shall apply where specific Q #12 TEK SCREW (TYP.) 19" details are not shown. t PAN HEAD ®12" O.C. RAIN GUTTER B. DESIGN CRITERIA CIO #10 PAN HEAD ® 12" O.C.- 52" 1. Building Code . . . . . . . . . . . . UBC 1997 FW- 2. Snow Load . . . . . . . . . . . . . 35 P.S.F. Z C i / 1 , I I TYPICAL SIDE FASCIA DETAIL 2 TYPICAL END FASCIA DETAIL Dead Load . . . . . . . . . . 10 P.S.F. 3. Wind Design: C= t �-/ N.T.S. N.T.S. Wind Velocity . . . . . . . . . . . . 80 M.P.H. W 0 Exposure. . . , . . . . . . . C I 4. Seismic Design: _� H v W Cc 0C 1-1/2"x1-1/2"x3/16" 3x6x1 4 PLATE / ANGLE BRACE BEAM ANGLE 2"x2"xi /4" Zone . . . . . . . . . . . . . . . . . 3 Jim ~t/J heim BEAM 3/+s AS REQUIRED C. 0 FOUNDATION 1Z X S � 3/16 1 1. Soil Bearing Pressure - 1500 P.S.F. (not tested) 1/s + 6x8x1/4 PLATE 2. Design Lateral Soil Pressure: 150 P.S.F./Ft. of depth. z 0 L2 63/1 BEA 3. All footings shall be placed on undisturbed soil or on granular fill mechanically compacted to not less than 95% U o 3/16 of modified proctor density (ASTM D-1557). p 3/16 6x1'/4 PLATED. CONCRETE C J g 0 o W W m m — 1. All concrete shall have o design 26-day compressive strength of 2500 P.S.I. E. STRUCTURAL STEEL i/e 1 (2) EA. A-3077, 1. Structural steel shall be fabricated and erected in o n i PURLIN 5/8" BOLTS NOTE: SPLICE PLATE ONE SIDE AFTER accordance with the latest edition of the following: "Specifications w BUTT WELDING PURLINS TOGETHER. PURLIN (a) AISC for the Design Fabrication and Erection of Structural Steel for Buildings'. n PURLIN BRACING DETAIL (AS REQUIRED) n PURLIN SPLICE DETAIL (AS REQUIRED) n BEAM BRACING DETAIL (AS REQUIRED) (b) AISC "Code of Standard Practice" excluding the following sections: 1.5.1, 3.3 (first sentence), m w 3, -. o k o N.T.S. N.T.S. N.T.S. 4.2, 4.2.1, 4.2.2, 7.5.4, and 7.11.5. (c) AISC "Specifications for the Design of Cold c a BEAM (4) EA. 5/8"x2-1/2' Formed Structural Members . e A d 2' snTCH weio +/6 z' sma 1B WLD A-307 BOLTS. (TYP.) 2. Structural steel shall conform to ASTM A-36 and ASTM A572 CR50. a z FON ERECTION ONLY p^^yl _ -1/4" PLATE STIFFENER SPOT WELD 3. Cold-formed structural steel tubing shall conform to g IL y- FIT TO BEAM WEB 1/{ 1/z• ASTM A-500, Grade B. PURLIN 4. All welding shall be performed by certified welders in a If accordance with the American Welding Society. Z f3/16 NOTCH COLUMN TO 5. All bolted connections shall use bolts conformingto ASTM A-307. ; SUPPORT BEAM 6. Metal roof deck shall be 22 Go. MBCI Architectural panel, 4x5x3/8 PLATE +/8 1/2 Classic series, or equal ASTM A-446, Grade D, min. — yield strength of 50 P.S.I. — 8"x8" F. PAINTING a s� GUSSET R DECK PANEL 8"x8" GUSSET R — 1. All exposed of steel shall be (spar STEEL STEEL COLUMN 13-12-79 cooling or approved! coating exposed or 6o IC 2. All welds andafter otherfabrication. COLUMN STD. PANEL CLIP prime coni C � f ® 16" O.C. STD. 3" DECK PANEL NOTE: Bolting shown is for erectinp se op n COLUMN/BEAM CONNECTION PURLIN CONNECTION DETAIL #2155 N.T.S. N.T.S. \, ,, L3 6& Srq 0 p �-- ATE MFS .:®• PP�® BUILDING INSPECTOR