Loading...
HomeMy WebLinkAboutELECTRICAL COMCHECK - 21-00586 - Just4Kids Pediatric Urgent CareCOMcheck Software Version 4.1.5.3 Interior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:Alteration Construction Site: Salem Highway U.S. 20 Artco Business Park - Block 1, Lot 2 Rexburg, ID 83440 Owner/Agent: IL Designer/Contractor: Casco 12 Sunnen Drive Suite 100 St. Louis, MO 63143 (314) 821-1100 midlanduc@cascocorp.com Project Information Energy Code: Just4Kids Urgent Care Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Health Care-Clinic 4800 0.82 3936 3936Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Health Care-Clinic (4800 sq.ft.) LED 1: A: 2x4: LED Panel 55W:1 26 58 1508 LED 2: B: 2X4 WITH DRYWALL ADAPTER: LED Panel 55W:1 5 58 290 LED 3: H: DOWNLIGHT: LED PAR 18W:1 96 20 1920 3718Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: Just4Kids Urgent Care K:\Urgent Care\Just4Kids\Projects\Rexburg ID 2100882\CDs\Calcs\Electrical\2100882 Lighting Energy Calcs.cck 07/27/21Report date: 71 ofPage COMcheck Software Version 4.1.5.3 Exterior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:Alteration Construction Site: Salem Highway U.S. 20 Artco Business Park - Block 1, Lot 2 Rexburg, ID 83440 Owner/Agent: IL Designer/Contractor: Casco 12 Sunnen Drive Suite 100 St. Louis, MO 63143 (314) 821-1100 midlanduc@cascocorp.com Project Information Energy Code: Just4Kids Urgent Care 1 (Developed rural area (LZ1))Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Parking area 8545 ft2 0.03 Yes 256 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 256 256 350 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 350 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Parking area (8545 ft2): Tradable Wattage LED 1: PB/PL/PR: Pole Lights: Other:1 3 89 267 LED 2: S: Wall Sconce: Other:1 2 10 20 LED 3: WF/WW: Wall Packs: Other:1 4 25 100 387Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES Project Title: Data filename: Just4Kids Urgent Care K:\Urgent Care\Just4Kids\Projects\Rexburg ID 2100882\CDs\Calcs\Electrical\2100882 Lighting Energy Calcs.cck 07/27/21Report date: 72 ofPage Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.5.3 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2018 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0, E3.0, E4.0, E4.1 C103.2 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E3.0, E4.0, E5.0 Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Just4Kids Urgent Care K:\Urgent Care\Just4Kids\Projects\Rexburg ID 2100882\CDs\Calcs\Electrical\2100882 Lighting Energy Calcs.cck 07/27/21Report date: 73 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.2. 2 [EL22]1 Spaces required to have light- reduction controls have a manual control that allows the occupant to reduce the connected lighting load in a reasonably uniform illumination pattern >= 50 percent. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0 C405.2.1, C405.2.1. 1 [EL18]1 Occupancy sensors installed in classrooms/lecture/training rooms, conference/meeting/multipurpose rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0 C405.2.1. 2 [EL19]1 Occupancy sensors control function in warehouses: In warehouses, the lighting in aisleways and open areas is controlled with occupant sensors that automatically reduce lighting power by 50% or more when the areas are unoccupied. The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Location on plans/spec: E2.0 C405.2.1. 3 [EL20]1 Occupant sensor control function in open plan office areas: Occupant sensor controls in open office spaces >= 300 sq.ft. have controls 1) configured so that general lighting can be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each control zone is reduced by >= 80% of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0 C405.2.2, C405.2.2. 1, C405.2.2. 2 [EL21]2 Each area not served by occupancy sensors (per C405.2.1) have time- switch controls and functions detailed in sections C405.2.2.1 and C405.2.2.2. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0, E3.0, E4.0 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Just4Kids Urgent Care K:\Urgent Care\Just4Kids\Projects\Rexburg ID 2100882\CDs\Calcs\Electrical\2100882 Lighting Energy Calcs.cck 07/27/21Report date: 74 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL23]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. See code section C405.2.3 Daylight-responsive controls for applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0 C405.2.4 [EL26]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0 C405.2.4 [EL27]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0 C405.2.5 [EL28]null Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time-of-day, or reduce connected lighting > 30%. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E3.0, E4.0, E5.0 C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0, E4.1 C405.6 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Location on plans/spec: E3.0, E4.0 C405.7 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E3.0, E4.0 C405.8.2, C405.8.2. 1 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Location on plans/spec: E3.0 C405.9 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E4.1 Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Just4Kids Urgent Care K:\Urgent Care\Just4Kids\Projects\Rexburg ID 2100882\CDs\Calcs\Electrical\2100882 Lighting Energy Calcs.cck 07/27/21Report date: 75 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C405.5.1 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. C408.1.1 [FI57]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E2.0, E4.1 Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Just4Kids Urgent Care K:\Urgent Care\Just4Kids\Projects\Rexburg ID 2100882\CDs\Calcs\Electrical\2100882 Lighting Energy Calcs.cck 07/27/21Report date: 76 ofPage Project Title: Data filename: Just4Kids Urgent Care K:\Urgent Care\Just4Kids\Projects\Rexburg ID 2100882\CDs\Calcs\Electrical\2100882 Lighting Energy Calcs.cck 07/27/21Report date: 77 ofPage