HomeMy WebLinkAboutCHECKLIST - 99-00038 - 103 Marianne Dr - Townhomesu FINAL- INSPECTION CHECKLIST 1998 INTERNATIONAL ONS AND TWO FAMILY DWELLING CODE Building Permit Numbers �2�j'q ^�O ,0 / Project: Job Address: �p�3 The following comments based on the 1998 edition of the Intemational One and Two Family Dwelling Code should be resolved before a occupancy permit is issued. This correction and specifications does Intemational regulation., list is not a building permit. The approval not permit the violation of any section One and Two Family Dwelling Code or any federa of plans of the I, stats or local i. OUTSIDE r� Grade (yard is sloped away from foundation) ✓Sidewalk Constructed as per Ordinance (5'mfi 'e� . de & 12" of granular borrow) from the i� Window Bars, hovers and Screens (shalt be releasable or removable inside for egress required windows) Window Wells (clear hon"zontal; dimensivns parallel to foundation wall shall be at leash as wide as the window and wider if needed to fully apes the window and the perpendicular dimension from window to window well is 24" min.) � Exterior Steps (7.75" max . riser & 10 if min. run) Stairway Handrails (required when rise is over 3(]" & 4" sphere €or spacing of uprights) Guardrails (provide for a If walking surfaces over 3(}'p high & �" sph�r� for uprights) Landings 36.11 x 36'$ rein, a landingis nod r�quired at th�t e top of the stair if a door does not swing out over stairs) Threshholds (1 '/4H main above floor or landing except wi�ere door does not swan R g over handing, 7 3/'F max. allowed) � Posts (required to be treated, redwood or cedar if in contact of concrete) � Roofing (no apparent leaks, installed properly, shingle lapped properly and roofing as per pians) Masonry (lintels asper �a�l� 703.x. �) Roof Ventilation (as per plan �tR n! R \p Chimney (built as per pians S) Chimney Crickets (needed when chimney "Is 30 " or wider parallel to ridged Chimney Height (ext -'end mire 2' above any portion of bui1ding be 3' rain higher than point chimney basses through roa� W1 1.0 but shall 0 II. INSIDE Egress Doors (all egress doors must be abbe to open from inside without use of key) Glazing (safety glass shall be provided in the following, in all doors, within 24' from door arc in closed position and below 60" , anyplace where paned is over 9 sq. ft, and boftom edge less than 1811 and top edge greater than 3C" above flava} Fireplaces (built as per plans) --%.Fireplace Hearth Extensions X16" min. front & 8" on sides) Bathroom Ventilation (either operable window or fan that vends directly to outside) Sinks, Bathtubs and Showers (check for caulking, operation and leaks) Stairway Illumination (switch at top and bottoms) I Stairs (? 3�" max. riser, 10"' min_ tread, nosing min. %"' & 1 Y4"' maxo required when treads are less than 10"' wide) Handrails (34 " min,, T 38 Pr max Y2" space min. to wall, and grip size; 1 '1/ " to 2" dia, & use 4" sphere for spicing of uprights when open to belo w triangular spare created by riser, tread and boftom of rail shah use 6"' sphere for spacing) . Guardrails (provide for walking surfaces hio.her than 3Q"� use 3E" mina he'gh# & use 4" sphere for spacing of uprights) Garage (check operation of garage doors, check for firewall penetrations and prooer electrical boxes, dear to house mint be said wood, metal insulated exp. door or 20 min. raked, ducts penetrating firewall must be 26 gauge min. & not open to garage) Egress Windows (check for 20" min, clear with a 24 "min clear height, 5. 7 min. sq. ft. opining and a 44" max. sill height) ME IM n4 Smoke Detectors (required in each sleeping room, outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of dwelling unit - on split levels, detector is required only an upper floor if no doers separate bevels -- all detectors interconnected without a disconnecting switch) Foam Pfastic (meets requirement of Section 317) Water Heater Anchorage {aver 4' with non rigid water connection shad be anchored �r to floor or strapped to, building) k Glothes. dryer ducts (solid metal ducts, no screws extending into duct & vest directly to outside) '� '9 Duch �uppvrts (metal ducts sha�� b� s�rppc��#�d min. � �' spacing& �o� metal as ner 2 manufacture's installation instructions) Duct Insulation. (ductin non conditioned arias shall be insulated} �G Line Supports (10 1 spacing for 314" and under, 12' spactong for 1" and o 6' spacing for tubing I ',��" and under} 13t vee- and