HomeMy WebLinkAboutREVIEW RESPONSE - 99-00023 - Ricks College - Storage ShedHAZARDOUS rarA�rER:.�,s ��rrAG�,MErrr AREA Ass, -a preface to the rensT �o�� cvera v�at �s�, s. 1. The facwty wig consist of: a rove a wad, and a floor. ate facifity v�1� �e open �n t �� sides. There will be no docxrLs, no electricity, and no exit route. 2. The materials stored at this facility will be in the primary containers, ie. &runis or bottles as appropriate. The containers wBI be stored in Factory Mutual Rated storage containers with secondary containment as a part of the storage containers. I previously submitted the brochures to the City of Rexburg Building Department for information. If the brochures are not avaable, I will be gW to provide additional copies, an intemet address, or a contact from the manufacturer. We da not intend oar wig we avow incompa#ible serials to be contained in the same moorage cabinet. The cabinets are on site and ava-flable for inspection if you desi're., Co mment Comment Response Number � e Please. provide details describing the "New complied. See Sheep Titled: Cinder Storage Building"" which has been Cinder Storage Building shown next to the Ha=dous Matefials Storage FoundatiProject #v.. PPLT- Iola,Builonthe plot plan.. 006,F Sheep 1. The buRding is being relocated from the area old to the'Navoo Haase AP artrnents t o the indicate d location., k2, Provide all dimensions for building from. Complied property lines and other buildings on the Plot Plan. 3. Aff pages must be stamped by a licensed Complied engineer or architect per 94 UBC Section 106. �e Kexb�g Fire Departmenthas included a The requested Occupancy is F list of iterns that must be addressed. I have changed from H-3 to H-7. a�ached a copy of the list. They have a�� issued a statement t. says the quantilles provided. on the Ricks CoUege Hazardous Wasle Storage Inventory List would mace a `:S" Occupancy possible as lag. as you do not store any ma.tenal above the revo�C,!!d quantity limits for the life of the structure. I have also attached a copy of that list. The other possib�li ould be an H-7 not and H-3. An H-7 occupancy would require additional requ�rements. Fire Department Review 1. Required Fire Flow No response required 2. Water Supply No response required 3. Fire apparatus access roads No response required 4. Access Roads and water supply, are required to No response required be installed and mads serviceable privy to and during times of construction 5. Installation of portable fire extinguisher A weather-proof cabinet will be provided to house a 10# ABC �xtingu�s�er. 6. Automatic Fire Extinguishing Systems No response required 7. Standpipes No response required S. VcnWatm-g Hood No response required 94- Firs Alarm No response required la-] Hazardous Materials Management Flan This document was submitted with the original pians I year ' ago. A copy is submitted herewith. Please notify Tam. Leman (356-2457) of the n� location. This will allow us 4F to infonn the appropriate person if there are any chanes in the future_ �. 0-21 Hazardous Materials Inventory Stat An inventory was submitted. Is a second one rewired with this package? t � MSDS � � ,t'` ' �The MSDS are managed by Tom Leman. Copies ars; ��� •� _-�- Thereis no location on site to keel the MSDS., 10-4 Isigma Si gnage currently �s placed on the outside of the cabinets defining the contents as acids, bases, or solvents. There are no doors or other enclosures that can be signed, 10-5 No Smoking Signs W� I Comply I0-6 SOUTce of ignition Will Comply 10--7 Fire Department Limon Tarn Deman, 356-245 7 Ries College Safety Officer 10-8 Protection from vehicles. The East} Soutk &rest sides are protected by concrete foundations wall that extend 4` above grade. The north elevation is protected by the same foundations walls plus the 4" steel cal. Supporting, the roof. Each cabinet i's constructed from 1/40T steel. 10-9 Sof i�acoatible materials Will Co ly. The four cabinets are labeled for acids, bases,r and solvents. They are avaiable for i«sp+ection at the site. 10-1Q Outdoor Control Areas Will Comply. weeds will be controlled with appropriate spraya and manual removal.. Stockpfflng or storage of materials will be cantrofled. Spfll Control Each storage cabinet has the sgifl control as an. integral _ pill of the desi V Monitor* wffl })e incoTarated. 10-12 � Tt--Nmperatue Control No temperature control is � required to prevent reactions. EmergencyAlarrm An approved emergency UFS 8003.. I , 10 sates that al= system shall be provided in buildings, the akrrms wiH be year each grooms, or areas used for starn.ge of bazardous interior exit. The facility has materials. Emergency alam-inrtiatmg devises none. The warm is shall be mstaffed outside of each interior exit or desigmted to alert accupauts. exit access door of storage buildings, rooms, or There are no occupants areas. Activation of an emergency alarm- assigned to the facility to be initiating device ShaU SDartd a local alarm to alerted. What is the best way alert occupants of an emergency situation to address this? involving hazardous materials-, 10-14 Superwsion At this point, we do not intend to have emergency alarms, detection or automatic fire-,extinguishng sys~tem& 1X1--15 Clearance from Combustible Agree and will camEply.