While reviewing your plans for the Rvc�£I.a,�d Aparimen�s weight room addition' I have
identified the following items that need your attention.
1, The carridar created on
the 2"d
level balcony
will have to be of one hour dire
resistive construction as
per 94
SBC Section
1005.7.
2. The windows inside the coz7idox crea#gid will have to conform to 94 UBC Section
1005, 8. Windows shall be 45 minute rated.
3. The swimming pool area must have one exit that either opens directly outdoors or
passes through one additional adjoining roam anly. The exit that currcni:Iy opens
to the outside vi11 now open to the Freight raon� w��tch Qper�s tg office, herefore
that dace can not be counted. as an exit. The swimming area was Iocked and no
one answered at the office when we Icnocked. We da not know if the other exit
from the swimrn.ing area passes through more than one adjoining room. The
maximum travel distance from the farthest corner of the pool area to the outside is
154 feet. Please address these issues when you resubmit your plwisfi
4. Identify designs loads as applicable.
Provide TH structural information.
f. Provide electrical and mechanical plans.
ri I IF T
leasc.., address these ilems and I Will IMMlately Continue Vne rQ vleN. Thank YOU fol
voul-i" consideration in these matters.-
can be reach 14
ed at'