HomeMy WebLinkAboutCODE REVIEW SEC 2B - 99-00010 - Upper Valley Industries - AdditionCode review far:
Project Id,, jp Dev . Workshop w/ other proposed addition
Address... 15 North end East St.
SECTION 4 2 U;e� 42J
C.C.0v 5 :r
DzRECTToN
K-912=1
BOUNDARY
Sen-aration wall
EAST Property line
SOUTH Separation wall
Tn]EST Public wdv
Allowable area increased
-- Sec. 505. 1
FL NAME
Y -Ir -
SEPARATION
AREA. INCREASE
0. 0 Fejt
120. 0 Feet
0. 0 Feet
114. 0 Feet
50.% for open
OCC MAX FLR
FIRE PRQTECTION
0. 0 Feet
12 0. 0 Feet
0.0 Feet
X4, 5 Feet
area on 2 sides .
AREA ALLOWED RATIO STATUS
2 Office
2 Apartment or Condo
TOTAL FOR FLOOR
1 Woodworking Area
1 Storage/Stock Room
B
R1
F1
S1
ok
ok
ok
ok
2640
1800
4440
4238
2640
12000
3000
5415
12000
12000
0.22
'0.6
0.82
0.35
0.22
ok
ok
ok
ok
ok
1 Storage/Stock Room
1 Office
TOTAL FOR FLOOR
BUILDING TOTAL
S1
B
ok
ok
3000
1800
11678
16118
12000
12000
12000
17
9 77
6.25
0.
0.97
0.9
15
ok
ok
ok
ok
The maximum allowed R1 area on the 2nd floor is 3004 sq.ft. unless the
building is of 1 hour fire -resistance con.structian, -- Sec. 3.10.2.2
Rooms for kindergarten, 1st and 2nd grade children are not permitted
an any f loor otherthin the 1st f loor , --- Sec. 305.2.3 Nate : They
may be on the end floor if there are at least 2 emits directly to.
the exterior for the exclusive use: of such occupants. -- enc. 2
The actual height of this building is 28. feet.
The maximum height of the building is 40. feed. -- Tables 5-B
Caere review far:.
Project Ic1.. DeV,
7�ddress: 15 North
Workshop w/ other proposed addition
end East St,
EXTERIOR WALL FIRE RATINGS AND OPENING PROTECTION
Table 5-A
NORTH
AREA SE?A.RATION WALL - See requirements listed. later in this report.
EAST
For
Occupancy
S1
N
F1
R1
SOUTH
Bearing
ing
mall
0
hour
0
hour
0
hour
a
hour
Non-Sear
ing
Wal I
Wall
0
hour
D
hour
0
hour
0
hour
Opening Construction
Protection Material
None
None
None
None
Any
Any
Any
Any
Parapet
Required
No
AREA SEPARATION WALL - See requirements listed later in this report.
WEST
For
Occupancy
S1
B
F1
R1
Bearing
--Bearing
Wal I
D
hour
0
hour
0
hour
0
hour
Ton
--Bearing
mall
4
hour
0
dour
a
hour
D
hour
Opening Construction
Protection Material
None
None
None
None
Any
Any
Any
Any
Parapet
Required
No
No
No
No
None -- No fire protection requirements for openings..
Code review
Project Id.;
Address: 15
for:
Dev.
North
Page # 17
Workshop w/ other proposed addition
2nd East St .
3 /4 hour --- Openirigs are to be protected with 3/4 hr fire assemblies.
50o of the area of the wall maximum. -- Table 5-A,
Footnote 5 & Seg. 5Q3.2.2
Maximum single window size is 84 sq.ft, with no dimension
greater than 12 feet. -- Sec. 713.8
Not Allowed -- Openings are not permitted in this wall.
(]THEA BUILDING ELEMENTS Table 6-A
ELEMENT MATERIAL RATIi1TG NOTES
Interior fearing wall Any Q hr
Interior nonbrg wall Any D hr See Footnote #5
Structural Frame Any 0 hr
Exterior Strutt Frame Any D hr See footnote #1
Shaft Enclosure ,Any 1 h r
Floor/Ceiling Assembly Any p hr
Roof /Ceiling Assembly any p hr
Stairs
Any Ione
NOTE.- dee Section 711 for shaft enclosure exceptions.
FOOTNOTES -
1} Elements in an exterior wall located where openings are not permitted
or whereprotection of openings is required, shall be protected
against external dire exposure as required tor exterior bearing walls
or the structural frame, whichever is greater. -- Table 6-A, footnote 1
DRAFT STOPS:
If there is
stops shall
exceed 1, x00
stops does n
If there is
stops shah
exceed 3, 000
stops does n
combustible
be installed
square fejt
cat exceed 60
combustible
be installed
square f eet
of exceed 60
construction in the floor/ceiling assembly, draft
so that the area of concealed space does not
and so that the horizontal dimension between
feet. -- Sic. 708,.3.1-1.3
construction in the roof/ceiling assembly, draft
so that the area of concealed space does not
and so thatthe horizontal dimension between
feet. -- Sec. 7U8.3.1.2.2
Code --L- e v ' e
I%A
Project Id.
Address: 15
f or:
Dev.
North
Page # 1�3
Workshop Jnr/ other proposed addition
end East St.
OCCUPANCY SEPARATIONS — Table 3-B
SI -B Ohr
S1 -F1 Ohr
S1 -R1 3hr
B -F1 Ohr
B -R1 1hr
F1 -R1 1hr
HEATING EQUIPMENT SEPARATIC]N
FOR 51 OCCUPANCY
qh
A 1 hr. occupancy
boiler or central
-- Sec* 302.5
FOR B
OCCUPANCYO
A I hr,
occupancy
boiler
or central
--- Sec.
302.5
FOR Fl
OCCUPANCY:
A 1 hr.
occupancy
boiler
or central
-- Sec.
3Q2.5
FOR R1
OCCUPANCY
A I hr.
0
occupancy
]oiler
or central.
-- Sec.
302.5 exc.
separation is
heating unit
separation is
heating unit
separationis
heating unit
separation is
heating unit
z
ADDITIONAL SEPARATIONS:
required around roomy containing a
greater than 400,000 BTU input..
required around rooms containing a
greater than 400,000 BTU input.
required around roams containing a
greater than 4 4 0, 0 0 0 BTU input.
required around
serving more than
A refrigeration machinery room shall b
of the building as required for an H7
horizontal occupancy separation may be
area of the machinery room. Structural
protected for the type of construction
A 1 hour separation is required from a
FOR Fl OCCUPANCY*
Woodworking areas with a f loor
separated from other areas by
-- 'fable 3-B, footnote #6
rooms containing
one unit .
e separated from tie remainder
occupancy regardless of area. A
limited to the actual f loor
supporting elements shall be
manly. -- Sec. 2802
n S1 occupancy.
area greater than 2,500 sq . f t . must be
one hour occupancy separation construction.
Code review
Project Id.:
Address: 15
far.
-Dear.
North
Page 4 19
Workshop w/ other proposed addition
end East St.
FSR R1 OCCUPANCyo
A 1 hr, accupancy separation is required around common storage and
laundry rooms. -- Sec. 310.x.2
A 1 hr. fire separation 'is required between dwelling units.
-- Sec. 310.2.2
SEC'T'ION # 2
EXIT REQUIREMENTS:
FL NAME NUMB MIN MIN PANIC RATED TJJC}OR NOTES
occ EXITS WIDTH HDWR CORRIDOR SWING
2 Office 26 1 0.4 � No No NIR ~92 �_��_`_
Apartment or Condo 9 1 0.2 No IVo NIR
TOTAL 35 2 0.9No Yes I
1 Woodworking Area 21 1. 0.4 Na N� N/F�
1 Storage/Stock Room 9 1 0.2 No No NIR
1 storage/Stock Roam 10 1 U.2 N� No �fR
I Office 18 1 0.3 Na No NIR 9
TOTAL 58 2 1.0 �'�io Yes Out
Ratted corridors are to have 1 hr, fi
and ceiling. -- Sec. 1Q05.7 re protection on both sides of walls
Door Q�enings are required to be protected
with 20 minute assemblies. -- Sec. 1005.8.1 Window openings are required
to be protected with labeled 3/4 hour assemblies. -- Sec. 1005.8.2
Elevator opening into a rated corridor shall be provided with an
elevator lobby at each floor containing a rated corridor. -- Sec. 1005.1.0
Walls and openings between the corridor and the elevator lobby are
required to be per Sections 10p5.7 and 1005.8 above.
In areas where 2 exits are required,
the maximum diagonal of the area or
When 2 exits are
to go in either
except for dead
1
required, exits
f-� 11 1
the minimum separation is 1/2 of
floor. -- pec. 1003.3
TilLl. 5 t be a r r a n r� r� c.--, f- 7-,r-
�-j--L t -n,: L--Luaj srom any
ends not exceeding
CL L -
point i
n a Corridor to
20 feet in length,,
it is possible
a separate emit,
Sec. 1005.5
Code review
Project Id.
Address: 15
for&
D.
Nom 'L---- h
Workshop wI other proposed addition
end East St.
Exit signs are required from all areas where 2 or exits
-- Sec. 1013.1
Mann exterior exit doors which obviously and clearly
as exits need not be signed when apgroved. -- exc. 1
Door swing is based on Sec. 1004.2 except as noted.
Occupant load factor is based on Table 10-A.
are required.
are identifiable
i•...«;,u�..-� �.•.- nZ) ..,_Z> aSE;,u on '.L'c1o1e 1 V -A 2XC2pt as noted.
Exit
width is
in feet
and
based on Sec. 1003.2.
Wzri
+-
r.» rq +- -�,
4 r.
+-.. L..-. tea;
___ a_
� _------ - � - -
Lr� lYY ILAL1i �,� �.�, ,.�� u�u�ueu dpproxlmately equally among exits.
Width shown for all areas is based an other emits. (0.2)
Width shown for 1st floor is based on other exits. (0.2)
Width shown for other flours & basements is based an stairways.
For the minimum width of doors, see Sec. 1004.6
For the minimum width of corridors, see Sec, 1005,2
For the minimum width of stairways, see Sec, 1006.2
(0.3)
FOOTNOTES:
9 } If this entire story has an automatic sprinkler system and an
automatic smoke -detection system is installed within the corridor,
and actuation of any detector shall activate warms is all areas
served by the corridor,, the corridor need not be rated if the
occupant load i,s less than 1�0. -- Sec. 1aa5.7 exc. 5
FLUSH AND SURFACE BOLTS:
Manually operated edge or surface -mounted flush bolts and surface
halts are prohibited. When automatic flush bolts are used, the door
leaf having the automatic flush bolt shall not have a door knob or
surfaces --mounted hardware,. The unlatching of any leaf shall not
require more than one Qpmration. -- Sec. 10Q4.3
LOCKS AND LATCHES:
All means of egress doors shall be readily
from which egress is to be made without the
knowledge or effort. -- Sec, 1004.3
apenable from the side
use of a key or special
-
�GY- oL_Lny ndraware may be used on the main exit when the maim exit
consists of a single door or pair of doors if there is a sign. stating
THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS. When urt 1 nrkimr�
aQor(s) must swing without operation of any latching device. exc,
Code review
Project Idl, 4P
Address: 15
far:
Dev.
North
Page ik 21
Workshop w/ other Proposed addition
2nd East St.
STAIR NOTES :
Public stairways
1) The rise of steps shall not be less than 4 inches or greater than 7
inches. The minimum run is 11 inches. The maximum variation is 3/8
inch in a flight of stars. -- Sec. J-006.3
2) The minimum width of a stairway is 36 inches, 44 inches if the
occupant load is greater than 49. -- Sec, 1006.2
Also see exit table above to see if minimum width is greater than
44 inches.
3) Provide a handrail on both sides of stairway 34 to 38 'Inches above
nosing. May be on one side of stairways less than 44 inches wide.
-- Sec. 1006.9 & exception 1
4) Provide a guard rail where drop off is greater than 30 inches.
-- Sec. 509.1
5) The minimum height is. 42 inches. Sec. 509.2
6) Open guardrails shall .ave intermediate rails or ornamental pattern
such that a sphere 4 inches in diameter cannot pass through.
-- Sec. 509.3 The triangular opening formed. at the riser, tread and
guardrail may be 6 inches, -- 509.3 exc. 2
7 1 Th p rn 1 n 4 mi i in A
the
�.JAL -LUUM -J-� 0 L-Ee- 6 incnes. Such clearance shall be
measured vertically from a plane parallel and tangent to the stairway
tread nosing to the soffit above at all points, -- Sec. 1006.15
8) Enclosed usable space under the stairs is required to be protected
as required for I hr. fire -resistive construction, -- Sec. 1006.12
ELEVATOR REQUIREMENTS:
1) When the elevator vertical travel is 25 feet or more, each associated
elevator lobby or entrance area and associated machine rooms ci-ated
shall be
provided with an approved listed smoke detector for elevator recall
purposes only, -- Sec. 3003.2
2 ) in building three or more stories in height, at least one elevator
serving all floors shall accommodate a wheelchair. See the complete
list of requirements in code book. -- Sec., 3003-4.1
3 Shafts (hoistways) haus ung elevators extending through more than two
floor levels shall be vented to the outside. The area of the vent
shall not be less than 3 1/2 percent of the area of the elevator
shaftf provided a minimum of 3 square feet per elevator is provided.
-- sec • 3004. Vents shall be capable of manual oner;zo-inn nl--)] tT
Cade review
Project Id.;
Address.: 15
fir:
rev.
North
Page # 2 2
Workshop w/ other proposed addition
.end East ,5t .
RAMP REQLTIREMEN'TS
1) The minimum width is 44 inches. If a ramp serves an occupant load of
49 or less, it may be 36 inches wide. If the ramp is serving a high
occupant load, check exit table above for required width.
__ Sec., 1007.2
2) Tf the ramp is part of the accessible route, the maximum slope is
1 : 12, A11 other ramps may have a slope of 1: 8 or less.
-- ,Sec. 107.3
37 When the slope is greater than 1:15, landings shall be provided at
the top, bottom and for each 5 feet of rise. Top landings and
inter -mediate landings shall be at least 5 feet in the direction of
travel. Landings at the bot-L,---om of ramps shall be at least 5 feet in
the direction of travel, -- Sec. 1007.4
4) Handrails shall be per stair requirements. -- Seg, 1007.5
5) The surface shall be roughened or shall be of Slip -resistant
materials. -- Sec. 1007.7
LANDINGS AT DOORS:
1} A floor or landing shall be provided on each side of doors, When
access for persons with disabilities is required. the floor or landing
shall not be more than 1I2 inch lower than the threshold. When access
is not required, the maximum is 1 inch. --- Sec 0 4 .9
2) Landings shall have a width not less than the W1h of the stairway
or width of the doorway, whichever is the greater, The minimum
length in the direction of exit travel is 44 inches. -- Sec. 10Q4.10
TRAVEL DISTANCE
The maximum travel distance in this building is 15Q feet. -- Sec. 1003.4
Cede review
Project Id.
Address: 15
for:
Dev.
North
Workshop W/ other proposed addition
2nd East St.
BUILDING ACCESSIBILITY:
1 ) This building including each tenant
one entrance which complies with the
2}
shad be provided with at least
accessible route provisions of
J - 1 . �L 1ec3SL bu percent
accessible. -- Sec, 11Q3.2.3
of all entrances shall be
vuuen more treat one exit is required from any accessible space, each
accessible portion of the space shall be served hy not less than two
accessible means of egress. -- Sec. 1104.3.1
3 } When an exit stairway is part of an accessible means of egress, the
stairway shall have a dear width of not legs than 48 inches between
the handrails. The stairway shall either incorporate an area of refuge
within an enlarged story -level landing or shall be accessed from
an area of refuge . -- Sec. 1104.1.2
The area of refuge shall have direct access to the stairway that serves
ito -- Sec. 1104.2.1
4} Each area of refuge shall be, sized to accommodate one wheelchair space
not less than 30 inches by 4$ inches for each 200 occupants, or
portion thereof. -- Sec. 11Q4,2,3
5} If the area of refuge is not within the stairway, it shall be separated
from the rest of the story by a smoke barrier having at least a one-
hour fire -resistance rating. Smoke barriers shall extend to the roof or
floor deck above. Doors shall be smoke and draft control assemblies
with a rating not less than 20 minutes. -- Sec. 1104.2.4
5} Two-way communications are required. -i Sec. 11Q ,2.5
7} Each area must be identified by a sign stating AREA OF REFUGE and the
international symbol of acces-I I s'b'l
g) NOTE: Exit stairways in buildings protected throughout by an approved
automatic sprinkler system are NST required to incorporate an area of
refuge. -- Sec. 1104.x,2 exception #2
ROOFING REQUIRENtENTS:
1} The roofing o� this building is required to be Class C. -- Table 15-A
2} See section 15Q4 and ICSH research reports for requirements.
Cade review
project Id. .
Address: 15
for:
Dev.
North
Workshop w/ other proposed addition
2nd East St.
AREA SEPARATION WALL REQUIREMENTS:
1) The area separation wall is required to be a 2 hr fire assembly.
Openings are limited to 25 percent of the length of the wa11 and
protected with a 1 1l2 hour assembly. -- Sec. 504.6-.2
2} If the building has a projection., 1 hr. protection is required on
the exterior wall each side of the area separation wall equal to
the depth of the projection . --� Sec. 504.6.3/ exceptionsIf the projection has a concealed space at the area separation,
wall, the area separation wall must extend through the projection.
3) If the area separation wall terminates at an inside corner, see
the article in 'Building Standards' Sep/Oct 1982 for requireme�.ts.
4} A 30 inch high parapet wall is required above the roofing,
-- Sec.504.6.4
See exceptions for alternate protection at roof_
The faces shall be momcombustible for the uppermost 18 inches
including counterflashing and coping materials. -- Sec. 504.G.5
AUTOMATIC SPRINKLER SYSTEMS
If openings are not
is floor area more
sprinkler system is
� minimum dimension
opening in every 5 4
provided in each 50 feet of exterior wall or there
than 75 feet from an exterior opening, an automatic
required. -- Sec. 904.2.E Nate: openings shall have
of 30 inches. There must be at least 20 sq.ft, of
lineal feet of wall.
An automatic Sprinkler
floor area greater than
If the building
sprinkler system
Residential or
units and guest
system is required in woodworking areas when the
2,500 sq.ft. -- Sec. 306.8
contains 16 or more dwelling
is required. -- Sec. 9x4.2.$
quick -response
room portions
snits, an automatic
standard sprinklers shall be used in dwelliong
of the build-ing,
STANDPIPE REQUIREMENTS
4
There is no requirement for a standpipe_
FOOTNOTES:
-- Table 9-A
Code review
Project Id.:
Address: 15
VENTILATION:
for:
Dev.
North
Page # 2 5
Workshop w/ other proposed addi�i�n
2nd East St.
x11 arias Customarily occupied by humans shall be provided with
ventilation by meaner of openabl e exterior openings with an area
less than 1f20 of the dotal floor area or shall be provided with
mechanically operated �r�r�fi; 1 a�; �n c, +______�riti
natural
of not
a
- --,Y,4G11L. ,DuCll �y�em sall be capable
Of supplying a minimum of l5 cubic 7fejt per minute of outside air per
occupant. -- Sec. 12a2.2. 1
WALL AND CEIL3NG FINISH
1) Tn3al1 and ceiling finish materials are required
Sec, 8Q4.1 and Tale 8-B.
2) Carpeting on the ceiling is required to have a
spread rating. --- Sec. 8D4.2
3} Textile wall coverings shall have Class I flame
and shall be protected by automatic sprinklers
acceptance criteria of U,B.C. Standard No, g,2
to cam,Ply with
Class I
spread.
or meet
-- Sec.
INSULATION NOTES:
1) All insulation material including facings are required
flame -spread rating of 25 or less and a maximum smoke
unless it is in a concealed spare and the facing is in
a wall or ceiling. -- Sec. 707.3 exc.2
2} Foam plastic insulations are required to be protected,
ADDITIUNAL REQUIREMENTS:
flame
rating.
the
805
to have
density
contact
�- Sec.
a
of 450
with
For S1 occupancy
For B occupancy
For F1 occupancy
Equipment, machinery or appliances which generate finely divided
combustibles waste or which use finely divided. comhustible materia!shal1 be equipped withan approved rnetho� of cflll�ction and
removal. -- Sec. 345.$
2602
Code review
Project Id.:
Address: 15
for:
Dev.
North
Workshop w/ other proposed addition
2nd East St .
For RI occupancy
1) Provide a window or door tc
sleeping, -- Sec. 1204. The
the exterior from every xoom used
window must provide a clear
u -L D.i sq. =t. , a clear height of 24 inches minimum), and
of 2 0 inches (min I'MUM) Sec. 3 10. 4
for
open area
a clear width
nil aua;ji-E� LoUlcis require exterior glazed openings equal to 1/10
or more of the flour area. Amin 10 sq, f t ,) --� sec. 12 03.2
3) All habitable rooms require an operable exterior openings equal
1/20 or more of the floor area. Amin 5 sq.ft.) -- Sec. 1203,3
4= Apartments - Provide a smoke detector in all sleeping rooms and
having access to sleeping rooms. -- Sic. 31Q,9,1.4
5} Hotel/Model - Provide a smoke detector in the main room or each
seeping roam. --- Sec. 310.9.1.5
6} The minimum ceiling in a habitable space is 7
kitchens, halls, and baths may have a ceiling
-- Sec. 31Q.6.1
to
feet 6 inches except
height of 7 feet.
Code review
Project Id,
Address: 15
for: Page # 2 7
Devo Workshop w/ other proposed addition
North end East St .
ACCESSIBLE FACILITIES:
NOTE.- Except as noted, section numbers listed below are from
CABD/ANSI A117.1 - 199Z
WATER FOUNTAINS AND WATER COOLERS:
At least 50 percent of drinking fountains, but not less than one,
provided on every floor shall be accessible_ -- UBS Sec. 1105,4.1
Accessible units must coMply with the fallowing:
1 } Shout is to be within 36 inches of the floor, -- Sec, 4,15.2,1
2 } Spout arranged dor parallel approach sfiall be located 3 inc�-ies
maximum from the front edge. Spouts of cantilevered units with
knees and tom clearances shall be located 15 inches minimum from
the vertical subpart and S inches maximum from the front edge.
-- Sec. 4.15,2.2
3} Spouts shall provide a flow of water 4 inches height minimum.
-- Sec. 4.15.x.3
4} Operable parts shall be located at or near the front edge of the
unit and shall caMply with 4.25.4 -- Sec. 4.15.3
5} A cantilevered unit is required to extend 17 inches minimum from
the vertical support. Clear knee space must provide a Clear area
of 8 inches in depth at 27 inches high and 11 inches at 9 inches
minimum above the floor. -- Sec. 4.15.4.1
6) Forward approach units shall comply with 4.2, Units in alcoves
shall comply with 4.x.4.4. Units not having the necessary knee
Cade review far :
Project Id .: Dev. . Workshop w/
Address: 15 North 2nd fast St.
is F -M nemg!�
other proposed additian
and toe clearance or clear space under them shall comply with
4.2.4 and have a clear floor space that allows a person in a
wheelchair to make a parallel approach. -- Sec. 4.15,4.E
TOILET FACILITIES
l} A 64 inch diameter unobstructed turning space is required in
the toiiet room. -- pec. 4.16.3. 4.2,3 & Fig. 84.2.3
2 } Water closet shall be mounted adjacent to a side wall or
partition. The distances from the side wall or partition to the
centerline of the water closet shall. be 18 in. Sec. 4.17.1
3 } tieVhen the accessible water closet is not in a stall
The clear floor space shall be 48 in minimum in front
of the water closet and 42 in from the center line of the
water closet on the side not adjacent to the wall,
-- Sec. 4.17.2 & Fig. X4.17.2
4} When theaccessible water closet is in a stall:
The stall shall be 50 in wide minimum and 56 in deep minimum
for wall hung water closets and 59 in deep minimum for floor
mounted water closets,, --- Sec. 4.18.3.1
If the doter swings into the Mall, the required depth shall
be increased. hy 3 6 inches minimum . -- Sec . 4.18.3o2
&
Fig. B4. 18.3. 1
5 } The bars are to be 33 to 36 inches above the t1oor and shall
he provided an the rear wall and on the side wall closest to
Code review
Project Id .
Address: 15
for:
Dev.
North
Page # 2 9
Workshop w/ other proposed addition
2nd East St.
the water closet. -- Sec. 4. 24. 2.2 & Figs. 84. 17. 3, 84. 17 . 4
and B4.18.3. 1
ai side grab bar is required to start within 12 inches of the
backwall and extend to 54 inches from the back wail. (The
minimum length of the bar is 42 in) -- Sec.. 4_1'7,4,1 &
Figs. B4.17.3 and B4.18.3.1
b} The rear bar shall be 24 in long minimum, centered on the
water closet. Where spare permits, the bar shall be 36 in
long minimum,with the additional length provided an the
transfer side. -- ,Sec. 4.17,4.2 & Figs, B4.17.3, B4.17.4
and X4. 18.3, 1
6 j The tap of the seat on the water claret is required to be 17
to 19 inches above the floor, -- SSG. 4.17.3 & Fig. B4.17.3
7 ) Accessible urinals shall be of the Mall type or wall hung with
the rim at 17 inches maximum above the floor. -- Sec. 4.19.2
8} A clew area of 30 X 48 inches minimum is required in front
of the urinal. Privacy shields shall not extend beyond the
front edge of the urinal rim, unless they are 30 inches apart
minimum_ -- ,Sec. 4.19.3
9} Accessible lavatories shall he mounted with the rim 34 inches
IP
maximum above the floor and a clearance of 29 inches minimum
from the floor to the bottom of the front edge of the apron..
-- Sec. 4.20.2-.1 & Fig. B4.20.3.1
l0} It shall extend 17 inches minimum from the wall. The clear knee
space shall be 8 inches in depth minimum at 27 inches minimum
above the floor and 11 inches in depth minimum at 9 in minimum
above the f loor . The dip of the overf low shall be ignored when
checking the clearances. -- Sec. 4.20.3.1 & Fig. 84.20.3.1
11) A clear floor spaces of 30 X 48 inches minimum shall be provided
in front of the lavatory and shall extend 19 inches maximum
under the lavatory-, -- Sec. 4.20.3.2 � Fig. B4.20.3.2
12} Water supply and drain pipes under lavatories shall be
insulated or otherwise treated to protect against contact.
-- Sec. 4.20.4
13) the bottom of mirror is required to be within 38 inches of
the floor. --- Seg, 4.16,6 & Fig. B4.20.3.1