Plan analysis based on
the 1994 TYni f corm Building Code
I
Number: DevWk #5
Name : Dev. . Workshop w/
15 forth 2nd East fit .
Date: March 22, 1999
other proposed additions
Contractor :
Occupancy: F11B-SI,B,Fi,Rl-E1,S1,R1 Architect:
Construction: V�NoV-N:V-N Engineer
Report By
None
None
Nance
JOE
NOTE: the code items listed in this report are not
complete listing of all possibly code requirements
It is a guide to selected sections of the code.
Report created using plan Analyst software by b w
Portions, of the material contained in. this program
from. the Uniform Building Code with the permission
International Conference of wilding Offica-als.,
SECTION # L4
- A0
SEPARATION
DIRECTIQN BOUNDARY AREA INCREASE
NORTH Separation wall D.0 Feet
EAST Property line
SOUTH Public way
WEST Pub t i c way
Allowable area 'increased
W - Sec,, 505,, 1
120. 0 Feet
135. 0 Feet
114. 0 Feet
100.$ for
LAIRD
intended to be a
A
n the 1994 UBC,
a. (719) 599-5622
are reproduced
of the
FIRE PROTECTION
0 - 0 Feet
124. 0 Feet
X9. 0 Feet
64.5 Feet
open area on 3 sides .
i
take review
Project Id.:
Address: 15
FL
for:
Dev. Workshop w/
North 2nd East St.
Page #F 2
other proposed addition
OCC MAX FLR AREA ALLOWED RATIO STATUS
-------------------------------------------------------------------
2 Conference Room B ok 300 16000 0.02 ok
2 Office B ok 1750 1b000 0.11 ok
TOTAL FOR FLOOR 2050 16000 0.13 ok
1 Woodworking Area F1 ok 14 6 0 4 116000 0.91 OVER
1 Office B ok 3080 16000 0.19, OVER
TOTAL FOR FLOOR 17684 1600E 1. 11 OVER
WARNING -- This floor i s over the allowed area.
BUILDING TOTAL 19734 32000 0. 62 ok
The maximum allowed R1 area on the end floor is 3000 sq,ft, unless the
building is of 1 hour fire-res-istance construction., Sec. 310.2.2
he actual height of this building is 28. feet,
The maximum height of the building is 400 deet. -- Table 5-B
EXTERIOR WALL FIRE RATINGS AND OPENING PROTECTION
NORTH
AREA SEPARATION WALL - See requirements li'sted later in this report.
EAST
For
Occupancy
Fl
B
SOUTH
For
Occupancy
F1
13
WAST
For
Occupancy
F 1
D
None
3 /4 hazer
Bearing
Wal I
0 hour
0 hour
Bearing
Wall
0 hour
D hour
fearing
Wall
0 hour
D hour
Nan -Bearing
Wall
0 hour
0 homer
Non -fearing
Wal_1
0 hour
D hour
,Non -Bearing
Wall
0 hour
0 hour
Opening
Protection
None
None
Opening
Protection
None
None
Opening
Protection
Nome
1rlane
Construction Parapet
Material Required
Any No
Any No
Construction Parapet
Material Required
Any No
Any No
Construction Parapet
Material Required
Any No
Any No
-- No fire protection requirements for openings*
---� Openings are to be protected with 3/4 hr fire assemblies .
Ir
Code review
Project Id.:
Address: 15
f or:
Dev.
North
Not Allowed --
ELEMENT
Workshop w/ -other proposed addition
2nd East St IV
50% of the areaofthe wall maximum, __ Table 5-A.
Footnote 5 & Sec. S03. 2 .2
Maximum single window sire is
greater than 12 feet V - Sec.,
Openings are not permitted in
OTHER BUILDING ELEMENTS
Interior Bearing wall
Interior nonbrg wall
Structural Frame
Exterior Struct Frame
Shaf t Enclosure
Floor/Ceiling Assembly
loaf/Ceiling Assembly
Stairs
MATERIAL
Any
Any
Any
Any
Any
Any
Any
Any
84 sq.ft.
713.8
this wa11.
ME
with no
NOTES
See Footnote
See footnote
dimension
#5
NOTE: See Section 711 for shaft enclosure exceptisorls.
FOOTNOTES:
1) Elements in an exterior wall located.v,rhere openings are not permitted
or where protection of openings is required, shall be protected
against external f 'ire exposure as required for exterior bearing walls
or the structural frame, whi
hic
ever s greater., -- Table 6-A, footnote 1
DRAF'-':L'-' STOPS *
f t
_7L here is
stops ops shall
exceed 1p0OD
stops does n
If there is
stops shall
exceed 3,ODD
Mops does n
combustible
be installed
square feet
of exceed 60
combust.ible
be installed
square feet
of exceed 6 0
6
OCCUPANCY SEPARATIONS
Fl -B Ohr
construction ice. the floor/ceiling assembly, draft
so that the area of concealed spaces 0 no
and so that the harizontal dimension between
feet., -- Sec. 708.3-1.1.3
Construction in the roof/ceiling assembly, draft
so that the area of concealed space does not
l.
and so that the horizontal dimension between
feet, -- Sec. 708-3.1.2,2
Table 3-B
Table
RATING
0
hr
0
hr
0
hr
0
hr
1
hr
0
hr
0
hr
None
ME
with no
NOTES
See Footnote
See footnote
dimension
#5
NOTE: See Section 711 for shaft enclosure exceptisorls.
FOOTNOTES:
1) Elements in an exterior wall located.v,rhere openings are not permitted
or where protection of openings is required, shall be protected
against external f 'ire exposure as required for exterior bearing walls
or the structural frame, whi
hic
ever s greater., -- Table 6-A, footnote 1
DRAF'-':L'-' STOPS *
f t
_7L here is
stops ops shall
exceed 1p0OD
stops does n
If there is
stops shall
exceed 3,ODD
Mops does n
combustible
be installed
square feet
of exceed 60
combust.ible
be installed
square feet
of exceed 6 0
6
OCCUPANCY SEPARATIONS
Fl -B Ohr
construction ice. the floor/ceiling assembly, draft
so that the area of concealed spaces 0 no
and so that the harizontal dimension between
feet., -- Sec. 708.3-1.1.3
Construction in the roof/ceiling assembly, draft
so that the area of concealed space does not
l.
and so that the horizontal dimension between
feet, -- Sec. 708-3.1.2,2
Table 3-B
K
Code review
Project Id.:
Addr e s s.: 15
for:
Dev.
North.
Workshop vel other proposed addition
2nd East St ,
HEATING EQUIPMENT SEPARATION:
FOR F1 OCCUPANCY:
A 2 hr.
boiler
--- Sec ,
occupancy
or central
302.5
FOR B OCCUPANCY*
A 1 hr,
bailer
-- Sec.
occupancy
or antral
302.5
separation is
heating unit
separation is
heating unit
ADDITIONAL SEPARATTONS:
required around moms cantazninQ a
greater than 400�Q�O BTU input.
required around rooms containing a
greater than 400 , 000 BTL input.
A refrigerationmachinery roam shall b
of the building as requzred for an H7
horizontal OCCUpaT1cy separation may be
area of the machinery room. Structural
protected for the type of construction
A 1 /'111 Y' C!Orin +- -i
e separated from the remainder
occupancy regardless of area. A
limited to the artiiai firirt-r-
& -I-c:;L on _Ls
, Erom an
FOR F1 OCCUPANCy:
Woodworking areas with a
separated from
--- `able 3-B,
SECTION # 1
floor
atner areas ny
footnotes #5
supporting elements shall be
only. --- Sec. 2802
F1 occupancy.
area greater than
one hour occupancy
EXIT REQUIREMENTS:
FL NAME NUMB
UCC
2 Conference Room 20
2 office 18
TOTAL 38
1 WOOdworking Azea 73
1 office 31
TOTAL 104
x, 500 sq. ft. must be
separation construction.
MIN
MIN
MANIC
RATED
DOOR NATES
EXITS
WIDTH
HDWR
CORRIDOR
SWING
1
0.3
No
No
N/R
1
0.3
No
No
N/R
2
1.0
No
Yes
N/R
2
1.2
No
Yes
Out
2
0.5
No
Yes
N/R
2
1.7
No
Yes
Out
�7
0
Code reV1aV+T
Project Id.�
Address: 15
Workshop w/ other proposed addition
2nd fast St
Rated corridors are to have 1 hr. fire protection on bath sides of walls
and ceiling. �-- Sec. 1005.7 Door o��nings are required to be pra�ected
with 20 minute assemblies. -- Sec. 1005.8.1 Window openings are required
to be protected with labeled 3/4 hour assemblies. -- Sic. 1p05.$.2
Elevators opening into a rated corridor shall be provided with an
elevator lobby at each floor containing a rated corridor, -- Sec. 100-5.10
Walls and openings between the corridor and the elevator lobby are
required to be per sections 1U05,7 and 10Q5.8 above.
In
areas where 2 exits
are
required,
the
maximum diagonal of
the
area or
When 2
to go
except
exits are
in either
for dead
the minimum separation is 1/2 of
f loor Sec, 1D03. 3
required, exits must be arranged so that
direction from any point in a corridor to
ends not exceeding 20 feet in length, ---
Exit signs are required from all areas where 2 or exits
-- Sec. 101361
Main exterior exit doors which obviously and clearly
as ex%ts need not be sign�c� when approved, -- exc� �.
Door swing is based on Sec. 1D04.2 except as noted.
Occupant lead factor is based on Table 1a -A.
it is possible
a separate exit,
Sec. 1005. 5
are required,
are identifiable
except as noted.
Exit width is .in feet and based on Sem. 1003.2.
Exit width is to be divided approximately equally among exits.
Width shown f or all areas is based on other exits. (0-2)
Width shown for 1st floor is based on other exits9' (0.2),
Width shown for other floors & basements is based on stairways. (0,3)
For the minimum width of doors, see pec. 1004.6
For the minimum width of corridors, see pec, 1p05,2
For the minimum width of stairways, see Sec. 1Q06.2
FOOTNOTES:
9} If this entire story has an automatic sprinkler system and an
automatic smoke -detection system is installed. within the corridor,
and actuation of any detector shall activate alarms is all areas
served by the corridor, the corridor need not be rated if the
nCcupant load is less than 100., -- Sec. 1005.7 exc. 5
a
Code reviewreview for;
Page # 6
Project Id. Dev. . Workshop w,/ other proposed addition
Address*.. 15 North 2nd East St.
FLUSH AND SURFACE BOLTS:
Manually operated edge or surface -mounted flush bolts and
bolts are prohibited. When automatic flush bolts are used,
leaf having the automatic flush bolt shall not have a door
surface -mounted, hardware, The unlatching of any leaf shall
require more than one operation. -- Sec. 1004.3
LOCKS AND LATCHES:
All means of egress
from which egress is
knowledge or effort.
Key -locking hardware
consists of a single
doors
shall
be readily
apenable
to
be
made
without
the
use of
-- Sec. 1004.3
may be used on the main
door or fair of doors if
f mom
a key
surface
the door
knob or
not
the s ide
or special
exit when the main exit
there is a sian s ta fi_ i ncT
THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS
door(s) must swing without operation of any latching
When unlocked,
deviced.. -- enc.
STAIR NOTES:
Public stairways o
1} The rise of steps shall not be less than 4 inches or greater than 7
F
nches. The minimum run zs 11 inches. the maximum variation is 3/8
�.nch in a flight of stairs., -- Sec. 1006.3
2) The minimum width of a stairway is 36 inches, 44 inches if the
occupant load is greater than 4.9. -- Sec. 10Q5.2
Also see exit tahle above to see if minimum width, is greater than
44 Triches.
3} Provide a handrail on :path sides of stairway 34 to 38 inches above
nosing. May be on one amide Q� stairways less than 44 inches wide.
-- pec. 1Q06.9 & excerption l
4 ) Provide a guard rail where drop off is greater than 30 inches S.
--_
Sec. 509.1
5) The minimum height is 42 inches., -- Sec, 5Q9,2
6} open guardrails shall have intermediates rails or ornamental pattern,
such that a sphere 4 inches in diameter cannot pass through,
--
Sec,, 509.3 The triangular opening formed at the riser, tread and
guardrail may be 6 inches. -- 5Q9,3 exc. 2
7} The mznimum headroom is 0 fit. -8 inches. Such clearance
measured vertically from a plane parallel and tangent to
tread nosing to the soffit above at all paints. Sec,
8} Enclosed usable space under the stairs is required to be
shall be
the stairway
1006.,,15
protected
M
Code review
Project Td.:
Andress: 15
f or:
Div.
North
Workshop w/ other proposed addition.
ion
2nd East oto
t
as required for I hr 4 fire -resistive construction, Sec,,. 1006.12
40
ELEVATOR REQUIREMENTS .
1) When the elevator vertical travel is 25 feet or more, each associated
elevator lobby or entrance area and associated machine rooms shall be
provided with an approved listed smoke detect -or for elevator recall
purposes only., -- . Sec. 3003 .2
Z 3 In building three or more stories in height, at least one elevator
L
serving all floors shall accommodate a wheelchai-r See the complete
list of requirements in code hook. -- Sec. 3003.4.1
3) Shafts (hoistways} housing elevators extending through more than two
floor levels shall be vented to the outside. The area of the vent
shall not be less than 3 1/2 percent of the area of the elevator
shaft, provided a minim= of 3 square feet per elevator is provided.
-- Sec. 3004. Vents shall be capable of manual operation only.
RAMP REQUIREMENTS:
1) The -minimum width is 44 Inches. If a ramp serves an occupant load of
49 or less, it may be 36 inches wide. If the ramp is serving a high
occupant load, check exit table above for required width.
-- Sec. 1D07.2
2) If the ramp is part of the accessible routtie axiC.mum s ope is
1:12. e1
All other ramps may have a slope of 1:8 or leis.
-- Sec. 1007 .3
3) When the slope is greater than 1;15, landings shall be provided at
the top bottom and for each .5 deet of rise. Top landings and
intermediate landings shall be at least 5 feet in the direction of
travel* Landings at the bottom of ramps shall be at least 6 feet in
the direction of travel, -- Sec. 1007.4
4) Handrails shall requirements. be'�er stairirements, -- sec. 1007.5
5 ) The surface shall be roughened or shad 1 be of slip -resistant
materials., -- Sec. 1007.7
I"
Code review
Project Id.,
Address: 15
for:
Dev.
North
Workshop w/ other proposed addition
2nd East Sto
LANDINGS AT DOORS
1) A floor or landing shall be provided on each side of doors.. When
access for persons with disabilities is required. the floor or landing
inch
shall not be more than 1/2 lower than the threshold. When access
is not required, the maximum is I inch. Sec. 1004. 9
2 ) Landings shall have a width not less th
an the width of the stairway
or width of the dQorway, whichever 'is the greater. The minimum
length In the direction of exit travel 1'.s 44 inches. -- Sec. 1004.10
TRAVEL D I S TANC E
The maximum travel distance in this building is 150 feet, -- Sec. 1003.4
BUILDING ACCESSIBILITY:
1 } This building
one entrance
CABQ/ANS I All
01
including each tenant
which complies waLth the
shall he provided with at least
accessible route -provisions of
� . 1. Ac least tU percent
accessible
a Sec. 1103. 2. 3
of all entrances shall be
wnen more that one exit is required from any accessible space, each
portion of the spare shall b�e' by accessi'ble paserved not less than twa
accessible means of egress.. -- Sec. 1104.1.1
3) When an exit stairway is part of an accessible means of egress, the
stairway shall have a clear width of not less than 48 inches between
the handrails. The stairway shall either incorporate an area of refuge
within an enlarged story -level landing or shall be accessed from
an area of refuge, -- Sec, 1104.1.2
The area of refuge shall have direct access to the stairway that serves
its Sec. 1104.2.1
4) Each area of refuge shall be sized to accommodate one wheelchair space
not less than 30 inches by 48 inches for each 200 occupants, or
portion thereof. Sec. 1104.x.3
5) If the area of refuge is not within the stairway, it shall be separated
from the rest of the story by a smoke barrier having at least a one�
hour fire -resistance rating. Smoke barriers shall extend to the roof or
floor deck above. Doors shall be smoke and draft' control assemblies
with a raking not less than 20 minutes* Sec. 1104,2,4
Codi review
Project Id. :
Address: 15
for.
North
Page # 5
Workshop W/ other proposed addition
2nd East St .
G } Two -- war cammunications are required. --- Sec.
i} Each area must be identified by a sign satin
international symbol of accessibility.
8) NOTE: Exit stairwaysin buildings protested
automatic sprinkler system are NOT required
refuge,, ---- Sec, 1104.1.2 exception #2
ROOFING REQUIREMENTS
1)
�'he
roofing
on this building is required to
2}
See
section
1504 and ICBQ research reports
AREA SEPARATION WALL REQUIREMENTS:
1104.2.5
g AREA OF REFUGE and the
throughout by an approved
to incorporate an area of
be Class C., -- Table 15-A
fir requirements.
l) The area separation wall is required to be a 2 hr Fire assembly.
Openings are limited to 25 percent of the length of the wall and
protected wish a 1 1/2 hour assembly, -- Sec. 50405.2
2} If the buildin-g has a projection, 1 hr. protection is required on
the exterior wall each side of the area separation walk equal to
the depth of the projection., --- Sec. 504.6.3, exceptions
If the projection has a concealed space at the area separation,
wall, the area separation. wall mush expend through the projection.
3) If the area separation wall terminates at an inside corner, see
the article in 'Building Standards' Sep/pct 1982 for requirements.
4 ) .A 30 inch high parapet wall is required above the roofing ,
---
Sec.504.6.4
,dee exceptions for alternate protection at roof.
The faces shall be momcombustible for the uppermost 18 inches
including caunterflashing and coping materials, -- Sem. 504.6,5
AU'I'4MATIC SPRINI{LER SYSTEMS.0
If Openings are not provided in each 50 feet. of exterior wall or there
is floor area more ,than 75 feet from an exterior opening, an automatic
sprinkler system is required. -- Sec. 904..2.2 Note: ��e�,�.ngs shall have
a minimum dimension of 30 inches. There mint be at last 20 sq.�t, of
opening in every �0 lineal fejt of wall.
An automatic sprinkler system is requixed in woodworking areas when the
floor area greater than 2,500 sq.ft. -- sc:!�rll4 3 0Go8
r-11
k,ode review
IV
Project
I P .0
Address: 15
for
:
Dev.
North
Page 10
Workshop w/ other proposed addition
2nd East St.
STANDPIPE REQUIREMENTS
There -is no requirement f or a standpipe.
FOOTNOTES:
VENT I LAT I ON
All areas customarily Occupied by humans
ventilation by means of openable exterior
less than 1/20 of the total flaor
mechanically operated ventilation
of supplying a minimum of 15 cubic
occupant, -- Sec. 1202.2.1
area or
system,
Table 9 -A
shall be provided with
th natural
openings with an area of not
shall be provided with a
Such system shall be capable
9 If
Lee,c per minute or outside air per
WALL AND CEILING FINISH:
F
1 ) Wall and ceiling f ina'sh materials are required,
Sec,. .804. 1 and Table 8--B.
2 ) Carpetingis on the ceiling required to have a
,spread rating-, -- Sec. 804.2
3) Textile wall coverings shall have Class If lame
and shall be protected by automatic sprinklers
acceptance criteria of U.13.C. Standard No. 8-2
INSULATION NOTES.0
l } All insulation material including
flame --spread rating of 25 or less
unless it is in a concealed space
to comply with
Class I
spread
or meet
-_ Sec.
facings are required
and a maximum smoke
and the facing is in
a wa-L-L oL cei-Al-ing. a-- 6ec,, '/ 0'/. 3 exc,2
2) Foam plastic 'insulations are required to be protected.,
I
ADDITIONAL REQUIREMENTS
For F1 occupancy
I
f lame
rating.
the
805
to have
density
contact
.___F ra..w Sem
.
equipment, machinery or appliances which aenerate f inel-u rllir3�=rq
r3 % 7
combustible waste or which
shall be equipped with an
removal, -- Sec. 306.8
For B occupancy
use finely divided combustible material
approved method of' collectionand
04ly'd
Code review
Project Id.:
Address; 15
Dev. Workshop v,r] other proposed addition
North end East ,fit ,
ACCESSIBLE FACILITIES:
NOTE.- Except as noted, section numbers 'listed below, are from
CABC7/ANS I A117.1 -- 1992
WATER FOUN'T'AINS AND WATER COC]LERS
At least 50 percent of drinking fountains, but not less than one,
provided on every floor shall be accessible. -- UBC Sec. 1105.4.1
Accessible units mint comply with the following"
1 ) Spout is to be within 36 inches of the floor..o
--- Sec, 4.15.2al
2} Spout arranged for parallel approach shall be located 3 inches
maximum from the front edgeoSpouts of cantilevered units with
knee and the clearances shall be located 15 inches minimum from
the vertical -I --support and 5 inches maximum from h.e front Pdc7e
3)
5}
-- Sec. 4.15.2.2
Spouts shall provide a
-- Sec.. 4.15.2.3
flow of water 4 inch -es Height minimum.
vperaDle parrs shall be located at or near the front
unit and shall comply with 4,25.4 -- Sec. 4,15.3
A cantilevered unit is required to extend 17 inches
the vertical support. Clear knee spice must provide
of 8 inches in depth at 27 inches high and 11 inches
minimum above the f loor, -- q�� a 1 � n I
Ji
edge o £ the
mminimufrom
a c1ear area
at 9 inches
6} Forward approach units shill comply with 4. 2. Units in alcoves
shad comply with 4.20 4. 4v Units. not having the necessary knee
Codes review
Project Id.:
Address: 15
Jff 0 r :
Dev.
North
Workshop w/ other proposed addition
end East Sts
and toy clearance or char space under them shall comply with
4.2.4 and have a clear floor space that allows a person in. a
wheelchair to make a parallel approcacll.. --- Sec. 4. 15.4.2
TOILET yAczLTTzFs:
1} A 60 inch diameter unobstructed turning space is required
the toilet room_ --- Sec. 4.15.3, 4.2.3 & Fig, B4.2.3
2 } Water closet shall be mounted adjacent to a szde wall or
partition. she distance from the side wall or partition to
centerline of the ,rater closet shad be 28 in. Sec. x.17.1
3) When the accessible mater closet is not in a stall:
The clear floor space shall be 48 in minimum in front
in
the
VL �-;G WQ L1Obt::�L- dl-lu 4z in zrom the center line of the
water closet on the side not adjacent to the wall.
-- Sec. 4.17.2 & Fig. B4.17.2
4} When the accessible water closet is in a stall:
The stall shall be 60 ire wide minimum and 56 in dee minimum
for gall hung water closets and 59 in deep minimum for floor
mounted water closets. -- Sec, 4.28.3.E
If the door swings into the stall, the required depth shall
be increased by 36 inches minimum, -- Sec. 4.18-3.2
Fid . B4 .18.3. 1
5 ) The bars are to be 33 to 36 inches above the floor and shall
be provided an the rear wall and on the side wall closest to
Code review
Project fid. :
Address: 15
for*
Dev.
forth
Page # 13
Workshop w/ pother proposed addition
2nd East St.
the water closet. -- Sec. 4.24.2.2 & Figs. B4.17.3, B4.17.4
and B4. 18. 3. 1
a} Side grafi bar is required to start within 12 inches of the
backwall and extend t0 54 .inches from the back wall. (The
minimum length of the bar is 42 in) -- Sec . 4. 17.4. 1 &
Figs. B4.17.3 and B4.18.3.1
b} The rear bar shall be 24 in long minimum, centered on the
water closet. there space permits, the bar shall be 36 in
fang minimum, with the additional length provided an the
transfer side, --- Sec. 4,17.4.2 & Figs. B4.17.3, 84 .17 .4
and B4.18.3. 1
6} The dap of the seat on the water closet is required to be 17
to 19 inches above the floor.. --- Sec. 4,17.3 & Fig* B4ol7a3
7 } Accessible urinals shall be of the stall type or wall hunk withthe aim at 17 inches maximum above the floor, -- Sec. 4.19.E
8) A dear area of 30 X 48 inches minimum, is required in front
of the urinal. Privacy shields shall not extend beyond the
front edge of the urinal rim, unless they are 30 inches apart
minimum. -- Sec. 4.19.3
9 } Accessible lavatories shall be mounted with the rim 3 4 inches
maximum above the floor and a clearance of 29 inches minimum
from the floor to the bottom of the front edge of the apron
,,
__ sec, 4.2a.2.1 Fig. B4.20o3al
10} Tt shall extend 17 inches minimum from the wail, The dear knee
space shall be 8 inches in depth minimum at 27 inches minimum
above the door and 11 inches in depth minimum at 9 in minimum
move the floor. The dip of the overflow shall be ignored when
Checking the clearances. -- Sec. 4.20.3.1 & Fig, B4.20,3.1
11} A clear floor space of 30 X 48 inches minimum shall be provided
in front of the lavatory and shall extend 19iLnc hes maximum
under the lavatory, -- See. 4.20.3,2 & Fig. B4o20*3*2
WE 12) dater supply and drain pipes under lavator
les shah be
insulated or% otherwise treated �o Protec�. against contact.
-_
Sec. 4.20A
13) The bottom of mirror 15 required to be within 38 inches of
the floor. -- Sec. 4.16,6 & Fig. B4.20-3.1