Loading...
HomeMy WebLinkAboutPLAN ANALYSIS AUG 28, 2000 - 00-00023 - Rexburg Airport - Hanger.f C Project Prof ect Address: CITY OF REXBURG ENGINEERING PO SQA 280 REYBURG, ZD 8344D �208)359-3020 Plan analysis based on the x.994 Uniform Build,ng Cede Nu mbr * D-JLrk Parkinson Rexburg Ai.rport Occupancy* Construction: -L Ranger Date: Contractor.dw Designer: Engineer: Report By: August 28t 2000 Teton West- Mendoza/Harr I' S es Mendoza./Harrig L CHRISTENSEN NOTE* The code items listed in this report are not complete .di t -i ng of all possible. code requirements It is a guide to selected �i. of the code. Report created using plan Portions of the material from the Uniform BUIlding International Conference DIRECTTON NORTH EAST SOUTH WEST Allowable -- Sec., L BOUNDARY Property line Public way Property line Public way area increased 503.1 Analyst software by coma.ned in thi3 program Code with the permission of Bu i officials. SEPARATION AREA INCREASE 0.0 Feet 55.0 Feet 0.0 deet 150.0 Feet 43.75% for open itd to be a in the 1994 USC* a. (719) 599-5622 are reproduced of the FIRE PET ION Feet 27.5 Feet Feet i00-0 Feet area on 2 sides; OCC MAX AREA AL T f� Y�4 sa —r '� �Ff � _. �l.A-e� as � _ as rwr +*T T.F1 � 7�A r� sb �• _ is _ : 4� �f iiia TT® i -L nanger S5 ok 3600 11500 0.31 TOTAL FOR FLOOR 3600 115oo 0.31 ok BUILDING TOTAL 3600 11500 0.31 ok The actual height of this building is 18. feet, The maximum height of the building is 40. feet, -- Tabie 5-B bode review for: gage 2 Project fid.: Dirk Parkinson Ranger Addre8s: Rexburg Airport EXTERIOR WALL FIRE RATINGS AND OPENING pRbTECTTUN Table 5-A NORTH For Bearing Non -Bearing Opening. Construction Parapet Occupancy Wall Wall Protection Material ' red I hour I hour Not Allowed Any Yes EAST For Bearing Non -Bearing Open-ing Construction Parapet Occupancy Wall Wall Protection Mater-lal Required S5 0 hour 0 hour None Any No SOUTH For Bearing Non-Beari'ng Opening, Construction Parapet Occupancy Wall Wall Protect'on Mater'al Required .5 1 hour I hour Not -Allowed Any Yes WEST For Bearing Non -Bearing Open-'Lng Construc-1--ion Parapet Occupancy Wallwall Prouection Material Required S5 0 hour 0 hour None Any No None No fire protection requirements for openings, 3/4 hour Openings are to be protected with r 50% of the area of the wail maximum.- - -ire assembiies. Footnote 5 & Sec. 503-2.2 Table 5-A. Maximum singie window sj-ze is 84 sq.ft. with no dimension greater than 12 feet. -- Sec. 713.8 41 Not Allowed Openings are not perm-itted In this wall. ELEMENT ETHER BUILDING ELEMENTS Table Interior Bearing wall MATERIAL RATING NOTES Interior nonbrg wall Any 0 hr Structurai Frame Any 0 hr Any 0 hr Exterior Struct Frame Any 0 hr See footnote #1 Floor/Ceiling Assembly Any 0 h,r See Footnote #9 Roof/Ceil-1-ng Assembiy Any 0 hr Stairs Any None FOOTNOTES. 1) Elementsiii an exterior email locato,d where openings or where protection of openings is required, against external fire eXposure as required for exterior bearing walls or the structural frame , wh'chever is greater, -- Tle 6 -Ar footnote dent materials, - Sec_ 9) In areas with vehicles or airplanes, the floor shall be of 1 0 sp Page # 3 Code review for,, Project fid.: Dirk Parkinson Hanger Address: Rexburg Airport DRAFT 'T STOPS If there I's Combustible construction in the ` ng assembly, draft stops shall be instalied so that the area of concealed space does not exceed 3,000 square feet and so that the horizontal dimension stops does not exceed 60 feet. -_ S� 708.3.1#,2 EXIT REQUIREMENTS,. L NAME NUMB MIN MIN PANIC RATED occ EXITS WIDTH RDWR CORRIDORSWIG ------------------------------------------- I _-- ---- -_- -- --___ -__-_------------- TOTAL 7 1 0.1, N o N/A N/R, Door swLng 1 Sec. 1004.2 exceptnoted. Occupant load factor is based on Fable 1�* Number of exits is based on Table 10-A except as noted. Exit sl nth is in feet and based on sec. 1003.2. Exit width ' tapproximately dividedl ` -It shown for ail areas 'is basted on other exits. (0.2) Width shown for Ist floor is based on other ex -its. .2) Width shown for other floors & basements is based on stairways. For the Tninimum width of doors, see Sec* 1004 For the minimum width of corridors, see Seg f f 1005.2 For the minimum width of stairways,see Sec . 1006.2 FOOTNOTES: (Q.3) FLUSE AND SURFACE BOLTS., Manuaily operated edge or surface -mounted flush bolts and surface hoits are prohibited. When automatic flush bolts are used, the door leaf having the automatic flush boli shall not have a door knob or surface -mounted hardware. The unlatchiLng P leaf shall not require more than one operationb. Sec. 10043 LOCKS AND LATCHES TA -11 means of egress doors shall be readily openable from the side f rom which egress i5 to be rnade without the use of a key or speciai knowledge or effort, See. 1004.3 Key-iock'ng hardware may be used on the main ex -it when t main exi nsis ts of a single door , doors i there 13 a sign stating THIS DOOR MUST REY--AIN UNLOCKED DURING -BUSINESS HOURS, When unlocked, Page 4 db Code review for. Project "Id.; Dirk Parkinson Ranger Address Rexburg Airport LANDINGS AT DOORS:, 1) A floor or landing shall be proms - ded on each side of doors. When access for persons with disabiltie�iis required. the floor or landing shall not be more than 1/2 inch lower than the threshold. When access i.s not required, the maximum is 1 inch. -- sec. 1004.9 2) Landings shall, have a width not less than the width of the stairWay or width of the doorway, whichever is the greater. The mini'MUM length in the direction of exit travei is 44 inches-, -- Sec. 1004.10 TRAVE L DISTANCE The maximum travel distance in this building is 150 feet, -- Sec. 1003.4 BUTLDTNG ACCESSIBILITY: i) This building includi ng each tenant shall be provided with at least one entrance wh C 11ch compl J' h iea with the accessible route rovisions 0 CABO/ANSI A11761. At least 50 percent of ali entrances shall be - accessible* -- Sec,. 1103.2.3 2) When more that one exit is required from any accessible space, each accessible portion of the space shall be served by not less than two accessible meano of egress. -- Sec* 1104wi.1 3) When an exit stairway is part of an accessible means of egress, the stairway shall have a clear w-ildth of riot less than 48 inches between the handrails. The stairway shall either incorporate an ar-ea of refuge Within an en -larged story -level -landing or shall be accessed from an area of refuge., Sec. 1104.1.2 The area of refuge shall have direct access to the stairway that serves fitly. -- Sec. 1104.2.1 4) Each area of refuge shall be sized to acco=odat-e one wheelchair space not le3s than 30 inches by 48 inches for each 200 occupants, or portion. thereof. -- Sec. 1104.2.3 5) If the area of refuge is not within the stairway, it shad be separated from the rest of the story by a smoke barrier having at least a one- hour fire-registance rating. Smoke barriers shall extend to the roof or floor deck above. Doors shall be smoke and draft control a semblies with a rating not less than 20 minutes, — Secv 1104*2,4 6) Two-way comraunications are required, -- Sec. 1104.2.5 7) Each area must be -identified by a s' tat-ng AREA OF REFUGE and the 3 Ign si international SyMbol of acc-.'4essibility. 8) NOTE: Exit stairways in buildings protected throughout by an approved -F automa-'--ic sprinkier system are NX required to incorporate an area refuge, -- sec. 1104.1.2 exception ft2 Code review for: Project Id.: Dir Virg Parkinson A -i rpo-r ROOFING REQUIREMENTS: 1) The roofing on this -- Table 15-A 2) See section 1504 and AUTOMATIC SPRINKLER If openings are not is floor area more sprinkler system is I a minimum dimers -in opening in every 50 Page 4 5 Hanger I building is requited to be ICAO research reports for Class B or better. requirements. SYSTEMS: P--,,--avided in each 50 feet of exterior wall or there I than �5 feet from an exterior opening, an automatic 0, required. -- Sec. 904.2.2 Note: Openings shall have of 30 inches. There must be at least 20 sq.ft. of lineal feet of wall, STANDPIPE REQUIREMENTS: There is no requirement for a standpipe.,, Table 9-A FOOTNOTES., NETTN: All areas customarily occupied by humans L vent -11ation by means of openable exterior I -Less than 1/20 of the total floor area or mechanically operated ventilation system. 4 L r)f g711 t shall be provided with narural b openings with an area of not shall be prov-1ded with a Such systein sl-iall be capable I M111-17tula Ot 1i cuu-1c ieet per minute of outs-ide air per occupant. sec. 1202.2.1 WALL AND CEILING FINISH: 1) Wall and ceiling finish materials are required Sec. 804,1 and IPable 8,B. 2) Carpeting on the ceiling is required to have a spread rating., -- Sec. 804.2 3) Textile wail coverings shall have Gass flame and shall be protected by automatic sprinklers acceptance criteria of U#B.c. Standard INSULATION NOTES. 1) All insulation material including flame -spread rating of 25 or less unless it Is in a concealed space I to comply with Class I flame spread or meet -- rating. the 80.5 0 acings are requmired to have a and a max Imum smoke density of 450 1 and the facing is 'in contact with a wa J- ul welling* -- sec. 107.3 exc.2 2) Foamplastic * Insulations are zequired to be protected. Sec. 2602 ADDITIONAL REQUIRIEMENTS: For S5 occupancy 40 Code review for: Page # 6 Project Id.: Dirk Parkinson Hanger Address: Rexburg Airport 0 ACCESSTBLE FACTLITIES, NOTE: Except as noteu, section numbers listed below are from CABG/NST A117.1 - 1992 WATER FOUNTAINS AND WATER COOLERS; At least 50 percent of drinking fountains, but not less than one, provided on every floor shall be accessible-. -- OBC Sec. 1105.4.1 Accessible unjL-L-s must comply with the following: 1) Spout J -S to be within 36 inches of the floor, -- sec. 4.15.2.1 2) Spout arranged for parallel approach shall be located 3 inches MaXIMLUTL from the front edge. Spouts of cantilevered units with knee and toe clearances shall be located 15 inches ml'nimum from the vertical support and 5 inches maximum from the front edge.. Sec. 4.15.2.2 3) 1 Spouts shall provide a flow of water 4 inches height minimum., Sec. 4 0 15.2.3 4) Operable parts shall be located at or near the front edge of the unit and shad comply with 4.25.4 -- Sec. 4.15.3 5) A cantilevered unit is required to extend 17 inches minimum f rom the vert-ical support. Clear knee space must provide a clear area of 8 inches in depth at 27 -inches high and 11 inches at 9 j-nches minimum above the floor. -- Sec. 4.15.4.1 6) Forward approach units shall comPly with 4.2. Units in alcoves shall comply with 4.2.4.4. Units not having the necessary knee 0 and toe clearance or clear space under them shail C'mPIV with 4.2.4 and have a clear floor space that allows a person irl a wheelr to make a parallel approach. SecM 4,15.4.2 TOILET FACILTTIES: 1) A 60 inch diameter unobstructed turning space is required in the toilet room ,. -- Sec. 4,,,.16,3, 462*3 2) Water cioset shall be mounted adjacent to a side wall or partition. The distance from the side wall or partition to the centerline of the water closet shall be 18 in. Sec. 4.17.1 3) When the accessible water closet 'is not in a stall: E The clear floor space shall be 48 in mini'mum in front of the water closet and 42 in from the center line of the water closet on the side not adjacerit to the wall., -- Sec, 4.17.2 & Fig. B4.17.2 4) When the acres sibie water closet io in a stali: The stall shall be 60 in wi-de minimum and 56 Jn deep minimum for wall hung water closets and 59 'in deep minimum for floor mounted water closets, -- Sec. 44.18.3.1 If the door Swings into the i stall, the required depth shall P be increased by 36 'Inches minimum, -- Sec. 4.18.3.2 & Fiq. B4 .18 .3. 1 The bars are to be 33 to 36 inches above the floor and shali be provided on the rear wall' de wali closest to the water cl- oset,, - and on the si Sec. 4.24.2.2 and B4.18.3*1 & Figs. IB4.i7.3, -B4.17.4 a) Side grab bar is required, to start within 12 Inches of the backwall and extend to 54 inches from the back wall. �The minimum length of the bar 'is 42 in) — I 9 srs a Code review for: Page 4 Project Id.: Dirk Parkinson Hanger Addressa- Rexburg Airport GLAZING REQUIREMENTS All glazing in hazardous locations is required to be of safety glazing material,, Sec. 240.6,3 & 2406A Locations: 1) Glazing in ingress and egress do,ors except jalousies, 2 F Giazing fixed andslid' .j -ng panels -of sliding door assembiies and panels in swinging doors other than wardrobe do -ors. 3) Glazing in storm doors. 4) Glazing in E111 unframed swingin g doors, 5) Giazqng in doors and enciosures for hot tubsr whiri 001s,, steam rooms, bathtubs and showers. Glazing in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glaz-irng is less than 60 inches above a standing surface and drain 'inlet. 6) Glazing in fixed or Operable panels adjacent to a door where the I nearest exposed edge of the glazing is within a 24 --inch arc of ither vertical edge of the door in a closed pos el L bottom exposed edge of the glazing is ition and where the walking surface. less than 60 inches above the 1 1 7) Glazing in an Individual fixed or operable pane ir other than those locations described in items 5 and 6 above, than meets all of the L foilowing conditions: A- Exposed area of an individual pane greater than 9 square feet. B. Exposed bottom- edge less than 18 inches above the floor. C. Exposed top edge greater than 36 inches above the fio0r. D. One or more walking 5urfaces within 36, inches horizontaily of the plane of the giazing, 8) Glazing in railings regardless of height above a walking surface. Inciuded are structurai baiuster panels and nonstructural panels, 9) Glazing In walls and fences used as the barrier for indoor and OutdOOI swimming pools and SPas when the bottom edges is .1e,ss than 60 inches above the pool side and the glazing is within 5 feet of the pooi or spa deck area. 10) Glazing. then ' In lls enclosing sta* then bottom and top of 3--rway -landings or within 5 feet of Cl CT C19 stairways where the bottom edge is than 60 "nches. above the walking -1 surface. 13 N Page # 7 Code review for. Project Id.. Dirk Parkinson Han i er Riiiresso. exL Airport Figs. B4.17.3 and B4.18.3ol m-- b) The rk"-C.,r bar shall be 24 in long mi'nimumf centered on the water closet. Where space permitsthe bar shall be 36 in long minimu.m., with -'L--he additional length Provided on the transfer sa-de. Sec. 4.17.4.2 & Figsw B4.17*3f B4.17.4 and. B4, 18. 3. 1, 6) The top of the seat on the wa-L:er cioset is required to be 17 N 7) to 19 inches above the floor, -- Sec& 4-17-3 & Fig. B4.17.3 Accessible urinais shall be cf the stali type or wall hung with the r' im at 17 inches maximum above the floor. -- Sec. 4.19.2 8) A clear area of 30 X 48 inche3 ininimum is required in front of the urinal. Privacy shields shall not extend beyond the front edge of the urinal rim, 11 h -- Sec. 4.19.3 unless they are 30 inches apart mini -mum,, 9) Acces5ibie lavatories shail mounted with the rim 34 inches Maximum above the floor and a clearance of 29 inches minimum from the floor to the bottom c)f the front edcje of the apron. 3 Sec. 4.20.2.1 10) It sh,ali extend 17 inches minimum froze the wall. The clear knee SP -ace shall be 8 inches in depth mInImum at 27 inches mlnljmum above the floor and 11 inches in depth minimum at 9 in mi*nimum above -the floor. The dip of the overflow sha-11 be ignored when checking the clearances., -- Sec. 4.20.3,1 & pig* B4420.3.1 11) A clear floor space of 30 X 48 i I nches Inrnimum shall be provi ided n front of the lavatory and shall extend 19 ' inches maximum under the la-vatory, Sec. 4.20.3.2 & Fig- B4.20.3.2 12) Water supply and drain pipes under lavatories shall be 4 insulated or otherwise treated to protect against contact. Sec, 4.20.4 13) The bOttOm of mirror is requ-ired to be within 38 inches of the floor, -- Sec. 4,16.6 & Fi,go B4620*3*i