CITY OF REXBURG
ENGINEERING
20 BOX 280
REXBURG, ID 83440
�208) 359-3x20
Plan analysis based on
the 1994 Uniform Building Code
Number: R-Skat ing
Name: R -Skating
255 West 4th South
Occupancy: A2,S1
Construction: V-1hr
Date:
Contractor -
Architect:
Engineer:
P
Report Dy.
June
ff-IMM
NOTE. - The code items listed in this Icepart are not
complete listing of all possible code requirements
It is a guide to selected sections of the code.
Report created using Plan
Portions of the mater.1"al
from the Uniform Building
InternatlLonal Conference
DIRECTION
NORTH
EAST
SOUTH
WEST
Allowable
-- Sec.
BOUNDARY
Public way
Property line
Property line
Property Line
area increased
505.1
12r
CHRISTENSEN
intended to be a
in the 1994 UBC.
Analyst software by b w & a.
contained in this program are
Code with the permission of
of Building officials.
SEPTATION
AREA INCREASE
160.0 Feet
10.0 Feet
36.0 Feet
10.0 Feet
(719) 599-5622
reproduced
the
FIRE PROTECTION
110.0 Feet
10.0 Feet
36.0 Feet
10.0 Feet
zv-6 for open area on
2 s -Ides.
FL NAME OCC
---------------------------------
MAX FLR AREA
ALLOWED
RATIO
STATUS
I Gymnasium A2
1 Storage/Stock Poom S1
TOTAL FOR FLOOR
BUILDING TOTAL
-------
ok 10500
ok 0-22
11122
11122
12600
12600
12600
12600
0.83
0.05
0.88
0,80
ok
ok
ok
ok
The allowed area for
NOTE: Accessory area
-- Sec. 504.3
the major use
cannot exceed
x C
was used for minor accessory areas.
the ail owed area 'in Table 5-B.
Page # 2
Code review for;
Project I.. * .-Skating
Address: 255 West 4th South
The actual height of this building is 20. feet.
The maximum i the building 1S 50. feet,
Code review
Pro_'tect Id.,
Address: 255
for:
ing
West 4th
South
Page # 3
EXTERIOR WAIL FIRE RATINGS AND OPENING PROTECTION
Table S --A
NORTH
For
Occupancy
S1
EASE
For
Occupancy
SOUTH
For
Occupancy
1
WEST
For
Occupancy.
1
None
3/4 hour
Bearing
Wall
1 hour
I hour
Bearing
Wali
I hour
hour
Bearing
Wall
I hour
1 hour
Bearing
Wali
I hour
hour
Not Allowed
Non -Bearing
Wall
hour
I hour
Non -Bearing
Wall
I hour
hour
Non -Bearing
Wall
I hour
1 hour
Non -Bearing
Wall
hour
1 our
Opening Cors t ruction Parapet
Protection Material Required
Norge Any No
None Any N
Opening COnstruction Parapet
Protection Material Required
None Any No
None Any No
Opening Construction Parapet
Protection Material Required
None AnV No
None Any No
Opening Construction Parapet
Protection Material Required
None Any No
None Any No
--No fire t requirements for -i
Openings are to be protected with fir
f the area of the wall maximum. -- Table
Footnote 5 & Sec* 503.2.2
Maximum single window size is 84 sq.ft. with
greater than 12 feet. -- Sec. 713.8
-� Openings are not permitted in this wall.
lei. enob P116
ELEMENT
Interio-r Bearing wali
Interior nonbrg wail
Structural Frame
Exterior rust Frame
Fl ili mb1
Roof/ceiling Assembly
Stairs
FOOTNOTES.
BUILDING ELEMENTS
MATERIAL
Any
Any
Any
Any
Any
Any
Any
Table 5-A
RATING
1 hr
I hr
1 hr
hr
Z hr
i hr
None
OTE
assemblies.
-A f
no dimension
See footnote #1
See Footnote #$
u
_Ln an exterior
waii located where
openings
permitted
or where
protection of
o-Qeninas is rui
against external fire exposure as
or the structural framef whichever
If the entire roof structure is 25
the fire rating may be allowed to
requirements, Sec. 606.5
F
required for eater-ir bearing
D greater, -- Table 6-A, footnote
feet or more above any floor,
oe eliminated. See limitations and
l
Code review
Frolect Id.:
Address; 255
fay:
R!=Sk2tinu
West 4th South
DRAFT STOPS:
If there is combustible
stops shall be installed
exceed 3,000 square feed
sops does not exceed 5€7
construction in the roof/ceiling assembly, draft
so that the area of concealed space does not
and so that the horizontal dimension between
feed. ,-- Sec. 708.3.1.2.2
OCCUPANCY SEPARATIONS Table 3-B
1 1
HEATING EQT ME T SEPARATION,41
1 hr. OcCUPancy'is required around room
boiler or central beating unit greater than 400,000 BTU input.
-- Sect 302.5
FOR S1 OCCUPANCY:
A I hr. occupancy separation is required around rooms containing a
boiler or central heating unit neater than 400,000 BTU input.,
-- Sec. 302.5
ADDITIONAL SEPAPATIONS:
refrigeLation machinery room shall be separated from the remainder
of the building as required for an H7 occupancy
horizontal occupancy separation may be limited to the actual floor
area of the machinery room. Structural supporting
Protected for the type of construction only. -- Sec. 2802
hour separation is required from an A2 occupancy.
EXIT .REQUIREMENTS
FL NAME NUMB MINIPAN IC RATED DOOR NOTES
occ EXITS DT CORRIDOR SWING
Gymnasium 700 3 11.7 Yes N/A 0
Storage/Stock Room 2 1 0.0
Code review
Project I ;
Address: 255
for:
.
-Skating
West 4th
South
Page # S
Exit signs are r' red from ali areas where 2 or exits
-- sec_ 1013.1
Main exterior exit doors which obviously
as exits need not be signedwhen approved. -- exc. I
Door swing Is based on Sec. 1004.2 except as noted
Occupant load factor based on Tabie10-A.
are required..
are identifiable
�� -LL)aseu on Tai)ie i ,A x noted.
Exit
width t.
is
in
feet
and based on Serf 1003.2.
I V r iy equaily among exi-ts.
Width shown for all areas I's basedon other exits. (0.2)
Width shown for Ist rigor is basedother exits. (0.2)
I shown for other floors basementsi based on �r
For the minimum width of doors, see Sec. 1004.6
For the J-. width of corridor3, see Sec. 1005.2
For the minimum width of stairways, see Sec. 1006.2
FT's
4) Panic hardware
See exception
M based on Sec. 1016.4.
for main exit in A-3 occupancies and churches,
FLUSH AND SURFACEBOLTS:
Manually operated edge or surface -mounted flush bQits
bolts are rl.. When automatic flush bolts are
leaf having the automatl"c flush bolt shall not have a
surface -mounted hardware* The unlatching of any lea:
require more than one operation. -- Sec. 100.3
LOCKS AND LATCHES:
All mases of egress
from which egress is
knowledge or effort.,
doors shall be readily
to be made without the
-- Sec,, 1004
and
door
shall
(d.3)
surface
the door
knob or
not
openable from the side
use of a key or special
L Air AT I i M CS 1 T Ld Vii' O
floor or landing shall be Providedeach
side of doors. When
access for persons with disabilitie3 is required. the floor or landing
steep not be more than 112 inch lower than
is not riff the maximum Is I inch. -` Sec. 1004.9
2) Landings hail have a width not less than the widtil
r width of the doorways whichever is ther.
The minimum
l n t � ice. the direction exit travel i t - Sec. 1004.10
-
TRAVEL DISTANCE:
The travel distance in this build,ing
"S 150 feet.
,pec. 1.4
Code Page # 6
Pro]ect Id.. -S tiro
Address: 255 West 4th South
B�7TLDING ACCESSIBILITY:
1) This building including each tenant shall be provided with at least
one entrance which complies with the accessible route provisions of
CABG/ANSI A117.1. At least 50 Percent- of all entrances shall be
accessible. -- Sec. 1103.2.3
2) When more that one exit. is required from any accessible space, eacli
accessible portion of the space shall be served by not iess than two
accessible means of egress,. -- Sec. 1104.1.1
3) When an exit stairway 'is part of an accessible means of egress, the
stairway shall have a clear width of not less than 48 inches between
the handrails. The stairway shall either incorporate an area of refuge
within an 47 enlarged story -level ianding or shall be accessed from
an area o -L refuge. -- Sec, 1104.1.2
The area of refuge shall have direct access to the stairway that serves
it& -- Sec. 1104.2.1
4) Each area of refuge shall be sized to acco=odate one wheelchair space
not less than 30 inches by 48 inches for each 200 occupants, or
portion thereof, -- Sec. 1104 .2
5) Tf the area of refuge 'is not within the :3tairway, it shail be separated
from the rest of the story by a smoke barrier having at least a one-
hour fire -resistance rating. Smoke barriers shall extend to the roof or
floor deck above. Doors shall be smoke and draft control assemblies
with a rating not less than 20 minutes. -- Sec,, 1104.2.4
6) Two-way communications are required. -- Sec. 11 04.2.5
7) Each area must be identified by a sign stat.ing AREA OF REFUGE and the
international symbol of accessibility..
8) NOTE: Exit stairways "in buildings protected throughout by an approved
automatic sprinkler system are NOT requi. 'incorporate an area of
refuge. -- Sec, 1104.1.2 exception #2
ROOFING REQUIREMENTS:
1) The roofing on this building is required to be Class B or better.
�_ Table 15-A
2) See section 1504 and ICBG research reports for requirements.
AUTOK_I�TIC SPRINKLER SYSTEMS
If openings are not provided in each 50 feet of exterior wall or there
is floor area more than 75 feet from an exterior opening, an automatic
lir system is required, Sec. 904.2.2 Note: Ope
M n-ings shali have
a minimum dimension of 30 inches. There must be at least 20 sq.ft. of
open3_ng in every 50 lineal feet of wall.
Code review for; Page 4 i
Project Id.: R -Skating
Address: 255 West 4th. South
STANDPIPE REQUIREMENTS:
There is no requirement for a standpipe. -- Table 9-A
0
fOOTNOTE'Ja
4} Tf the total occupant lead for the building is greater than 1000, then a
class II standpipe with a hose is required.. --- Table 9-A
FIRE ALARM SYSTEM:
fire alarm system is required. -- Sec. 303.9
The alarm system is to be as set forth in the Fire Code.
VENTILATION:
All areas customarily occupied by humans shall be provided with
ventilation means enable exterior oneninas with an ArPA
less than 1/20 the total floor
mechanically operated ventiiation
f supplyinq ami -nim -um -of 15 cubic
occupant. -- sec. 1 2 2.2 # 1
area or
system,.
shall be provided with
natural
of not
a
such system shail be capable
zeez per minute of out i
WALL AND CEILING FINISH:
1 Wall and ceiling finish materials are required
Sec. 804.1 and Table 8-B.
2)
Carpeting on the ceiling i s required to have
spread rating, -- Sec. 804.2
3) Textile wall coverings shall have Class I flame
and shall be protected by automati-csprinklers
acceptance criteria of U.B.C. Standard No. 8-2
to comply with
Class I flame
spread
r meet
-- Sec.
I -TI NOTES:
1) Ail insulation material including facings are1ped
flame -spread rating f 25 or iess anda maximum smoke
unless It in a concealed space and the facing is in
wall or ceiiing, -- Sec. 707.3 exc.2
rating.
the
805
to have
density
contact
a
of 450
with
UCLA 1 1 .re requa-rect to be protected., Sec. 2602
Page # 8
Code review for:
P
6 roject Id. 4 .-Skating
Address: 255 West 4th South
ADDITIONAL REQUIREMENTS..
For A2 occupancy
STAGES:
1 .) The minimum type of construction for stages shall be as required
for the building except that the finished floor, 'in all types of
construction, may be of wood. -- Sec. 405.3.1
2) If the stage height is 50 feet or more
r it shall be separated from
the rest of the buildi-ng by not less than a two-hour occupancy
separation. If the height is less than 50 feet separation may be
one-hour, -- Sec. 405.3.1
3) Dressing roomsf workshops storerooms, and other accessory spaces
shall be separated from each other and the other building areas by
a one-hour occupancy separation, -- Sec. 405.3.2
4) Emergency ventiiati-on shall be provided for ail stage areas greater
than 1000 sq.ft. for having a height greater than 50 feet to provide
a means of remov,119 smand combustion gases directly to the outside.
Ventilation shall be by one or a combination of the following.
a) Smoke Control - A means shall be provided to maintain smoke ievel
not less than 6 feet above the highest level of assembly seating
or above the top of the proscenium opening. It shall be connected
to both normai and standby power, -- Sec. 405,3.3.1
b) Roof Vents - Two or more vents all be located near the center
of and above the highest part of the stage. The net free vent area
must be at least 5 percent of the:, stage area-,, -- Sec. 405.3.3.2
5) The pros centum opening shall be protected by an approved fire curtain
or an approved water curtain. The fire curtain shall be designed to
close automaticaily and resist flame and smoke for 20 minutes.
Sec. 405.3.4
6) Grida-rons, fly galleries, and pinrais. s shall be constructed of
materials cons-istent with the building type of construction.
�_ Sec. 405-3.5
For S1 occupancy
F100 -r -1st Occupancy -Gymnasium
When seats are not fixed, the capacity of th-is area is required to
be posted at700 occupants 'in a conspicuous place on an approved
sign near the main exit. Ser- inn? �
Code review
Project Id.:
Address* 255
f Or
R - Skating
West 4th
South
,.E1 FACILITIES ,
NOTE.- Except as notedr section numbers
listed below are from
CABG ANST A117.1 - 1992
WATERFOUNTAINS AND WATER COOLERS
At least 50 percent of drinking fountains, but not less than one
provided on every floor shall be accessible. -- UBC Sec_ 1105.4.
Accessible omits must comply with the following:
1 ) Spout -is to be within 36 inches of the floor. -- Sec. 4.15.2.1
) Spout arranged for parallel approach shall be located 3 inches
maximum from the front edge. Spouts of cantilevered units wl
t
knee and toe clearances shall be located 15 inches minimum from
the vertical SUPPOrt and 5 inches maximum from the front edge.
-- Sec. 4.15.2*2
3) Spouts shall provide a flow of water 4 'aches height mini
-- Sec. 4015.2.3
4) Operable part shall be 1c)cated at or near the front edge of the
unit and shall comply with 4.25.4- Sec. 4.15.3
5) A cantilevered unit is required to extend 17 inch -es minimumfrom
the verticai support. Clear knee space must provide a clear area
of 8 'inches in depth at 27 inches high and 11 ladies at 9 inches
minimum above the floor. - Sec. 4.15.4.1
6) Forward approach units shall compiy with 4.2. Units in alcoves.
shall comply with 4.2-4.4. Units not having the necessary
and toe clearance or clear space under them shall comply with
4.2.4 and have a clear floor spice that allows a person in a
wheelchair to make a parallel approach., Sec_ 4,15.4.
TOILET FACILITIES
1 inch diameter unobstructed turning space is required
the toilet room. ---- Sec. 4.16.3. .2* Fig. B4.2.3
2) Water closet shall be mounted adjacent to a side wall or
partition. The distance from the side wali or partition
centerline of the water closet .shall be 18 in. Sec. 4.17.1
3) When the accessible water closet is not in a stall:
The clear floor space shall be 48 in minimum in front
of the water closet and 42 in from the center line of the
water closet on the side not adjacent to the wall
-- Sec. 4.17.2 & Fig. B4.17.2
4) When the accessible water closet 'I's in a stall:
The stall shall be 60 in wide minimum and 56 in deep minimum
for wall hung water closets and 59 in deep minim
um for floor
mounted water closets. Sec. 4.18.3.1
If the door swings into the stall the required depth
shall
be 'increased inches ini ,, -- Sec. .1
iw .1..1
The bars are to be 33 to 36 inches the fly
or and shall
e provided on the rear wail and on the sidewal
the water closet. -- Sec. .2. Figs.
and .1t.1
a) Side grab bar is requirecl to start within 12 inches of -
the
backw.1i and extend to, 54 inches from the back wa-11-0 (The
minimum length of the bar is 42 i --
Code review
Project Id.:
Address: 255
for:
R - Skating
West tai South
Figso B4.17.3 and B.4.18.3.1
b) The rear bar shall be 24 in long i
m -"n
iraum, centered on the
water i t . Where space permits, the bar shall be 36 in
long minimum, with the additional -length prov]Lded on the
transfer side. -- Sec. 4.17.4.2 & Figs. B4.17.3. B4..1-7.4
and B4.18.3.1
6) The tou, of the seat on the water closet is required to be 17
to 19 inches above the floor, -- Sec. 4.17.3 & Fig. B4.17.3
7)
Accessible urinals shall be of the stall type or wall hung with
the rim at 17 inches maximum above the floor. oec. AL.19.2
8) A clear area of 30 X 48 inches minimum is required in front
of I Che
the I nal. Privacy shields eids shall not extend beyond t
front edge of the urinal rim, unless they are 30 inchesapart
2 1
rein -I& -- Sec. 4.19.3
9) AccessIbie lavatories shall be mounted with the rim 34 inches
maximum above the floor and a clearance of 29 inches mini'MUM
from the floor to the bottom of the front edge of the apron'.
-- Sec. 4.20.2.1 & Fig. B4,20.3.1
10) It shall extend 17 -inches minimum from the wall. The clear knee
space shall be 8 inches in depth minimum at 27 inches m,_Lnimum
above the floor and 11 inches in depth minimum at 9 in minimum
above the l r, The dip of the overflow shail be ignored when
checking the -clearances. -- Sec. 4.20.3.1 & Fig. B4.20.3.1
1 ) A clear floor space of 30 X 48 inches minimum shall be provided
in front of the lavatory and shall extend 19 inches maximum
under the lavatory. -- sec. 4.20.3,P12 & Fig. B4.2063.2
12) Water 3UPPly and drain pipe3 under lavatories shall be
insulated or otherwise treated to protect against contact,
-- Sec. 4.20.4
13) The bottom of mirror is required to be within 38 inches of
the floorf -- Sec. 4.16.6 & Fig. B4.20.3.1
Code review f or: Page # I I
PrO3 est Id - R-Skat wing
Address: 255 West 4th South
GLAZING REQUIREMENTS
All glazing 'in hazardous locations is required to be of safety
Vazing Material, Seco 2406.3 & 2406.4
Locations:
1) Glazing in ingress and egress doors exceptJ_ous'-
les.
2) Glazing in fixed and sliding panels of slidi'ng door assemblies
I i
and panels in swin in do -ors other than wardrobe doors.
3) Glazing in storm Coors.
4) Giazing in ail unframed sw"ng"
i ing doors.
5) Glazing in doors and enclosures for hot tubs, whirlpools, saunclL:),
I i
steam ro-omst, bathtubs and showers. Glazing n any portion of a
building wail enclosing these compartments where the bottom exposed
edge of the glazing is less than 60 inches above a standing 3urface
and drain inlet.
6) Glazing in fixed or operable panels adjacent to a door where the
nearest exposed edge of the glazing is within a 24 -inch arc of '
either vertical edge of the door in a closed Position and where the
bottom exposed edge of the gJazing J I
walking surface. is le3s than 60 inches above the
7) Glazing ' V * P
in an individual fixed or operable panelf other than those
locations described in items 5 and 6 above, tkian meets all of the
11
foliowing conditions
A. Exposed area of an individual pane greater than 9 square feet.
B. Exposed hottom edge less than 18 inches above the floor.
C. Exposed top edge greater than 36 inches above the fioor.
D. One or more walking surfaces within 36 -inches horizontally of
the plane of the glazing.
8) Glazing in railings regardless of helght above a Ing surface.
Included are structural baluster panels and nonstructural in -fill
panels,
Glazing in walls and tences used as the barrier for rndoor and
I
Outdoor swimming pools and spas when the bottorn edgels 'S less than
60 inches above the pool side and the glazing is within 5 feet
of the pool or spa deck area.
10) Glazing in walls endosing stairway landings or within b -
bot t om and top of sta,
irways where the bottom edge is less
than 60 'Inches above the walking surface.