HomeMy WebLinkAboutINSPECTION SEQUENCE - 01-00046 - Greenbrier Association Apartments - 9 UnitsBUILDING INSPECTION SEQUENCE
Tyke of Inspections-, For on-site construction, frim time to time the building official, upon
notification from the permit holder or his agent, shad rake or cause to be made any necessary
inspections and sham either approve that portion of the construction as comped or shall notify
the permit holder or his agent' wherein the same fails to comply with phis cede.
I . LAYOUT- Loi corners staked, staking ire place f og bun ding, prior to excavation:
2. FOOTING. Commonly made after poles or piers are sed or trenches or basement
areas are excavated. Forms, and horizontal reinforcing tied in place,
vertical reinforcing cut and on jib site or tied in place.
3. FOUNDATION INSPECTION:
The foundation inspection shadl included excavations for thickened slabs
intended for the support of bearing walls, par#�tians, structural suppo�s, or
equipment and special requirements for wood foundations. All forms and
reinforcing steel, etc., shall be in place,
4. PLUMBING, MECHANICAL ASD ELECTRICAL:
Rough inspection: Commonly made prior to covering or concealment,
before fixtures ars set, and prior to framing inspection.
5. TRUSS INSPECTIONS
Inspections of Trusses.
6. FRAME INSPECTION:
Commonly made after the roof, all framing, firestopping, draftstopping and
bracing are in place and after the plumbing, mechanical and electrical
sough inspections are approved. (Electrical inspection performed through
Stade of Idaho electrical Bureau)
7. LATH AND/OR WALLBOARD INSPECTION:
Commonly rade after all lathing and/or wallboard interior is in place, but
before any plaster is, applied, or before wallboard joints and fasteners are
taped and finished.
S. FINAL PLUMBING AND NEATIh�G If��PE���C]N:
Al! systemsin place, fixtures set, ready dor occupancy
9. SIDEWALK INSPECTIONS:
After forms ars set, prier to p�ac�n� rancre�e_
10. FINAL INSPECTION:
Commonly made after the buildina competed eo�l��e� and ready for occupancy .
11. OCCUPANCY PERMIT:
issued when, on final inspection, buvai ng is ready to occupy..
12. OTHER INSPECTIONS:
In addition to the caned inspections above, the building department may
maks or require any other inspections to ascertain compliance with this
cads and ether haws enforced by the building department-
INSPECTION
CARD
The permit holder or his agent shall pos e inspection record on the job site in an accessible
and conspicuous piece to allow the building official to mike the required entries. The record
shall be maintained by the permit holder until the final inspectian his been made and arowed.
I have read the above and will comply ire my requests for inspections by giving 24 HOURpp
NOTICE prior for inspc' cl6t ic�n tobe made.
Electrical.- 624-376.:t
Plumbing.- 359 H2O e
Sigiqature�
or 313 or 359-3034
Building: 359-3020 ex 326 or 313
Date: