HomeMy WebLinkAboutFIRE DEPT. REVIEW - Newport Investments - 559 S 4th W - Rezone from HDR to HDR2REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1997 Uniform Fire Code Plan Review Plan Date: 6-21-01 Review Date: 6-26-01 Building Name: Apex Apartments, Married Student Housing Building Address: 7th South/6th South and 4th West Stories: U/K Type of Construction: U/K Occupancy Classification: R-1 Existing Floor Area: N/A New Construction Floor Area: U/K 1).Required Fire Flow (Appendix III -A): U/K Comments: Need to know the square footage, dimensions, height, construction type, etc. and whether or not each building is sprinkled to figure fire flow. 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: U/K Fire Hydrant Flows: U/K Fire Flow Test Location: Fire Flow Supplied By: Other Approved Water Source: Water Supply Acceptable: U/K Fire Hydrant Location Acceptable: U/K Water Supply Comments: Unknown at this time, plans incomplete in regard to building size, height, sprinklers, type of construction, etc. 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Complete Road Acceptable: NO Comments: Access roads incomplete. Need to know if 4th West is going to be completed from 6th South to 7th South in addition if 6th South will be completed to east side of property. Access within parking lots needs to be addressed. Twenty-eight foot radius required on all corners, posted R No Parking, Fire Lane within parking lot. 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: U/K Type Provided Acceptable: U/K 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: U/K Type Of System Being Installed: Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: Comments: Need more complete plans 7).Standpipes (Article 10 Section 1004) Required: U/K Type Required: Comments: 8).Ventilating Hood And Duct Fire Extinguishing System (Article 10 Section 1006.2) Required: U/K Type Being Provided: Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4): Portable Fire Extinguisher Shown (Article 10 section 1006.2.7): Comments: 9).Fire Alarm Systems (Article 10 Section 1007)Required: U/K Type Of System Required: Manual: Automatic: Both: Type Of System Being Provided: Manual: Automatic: Both: Components Of System Shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: 10).Other Corrections That Are Required By Special Occupancy Or Conditions: Plans As Submitted Are Acceptable: NO Plans Checked By: Chris Huskinson Date: June 26, 2001 Please furnish comments back to the plan reviewer in the following manner: Written Comments: YES New Plans: YES Need a more complete set of plans for fire department access, water supply, sprinkler system, fire alarm system, construction type, etc. Plans submitted incomplete, especially for access.