e Comments: Tom, About the reinforcing in the concrete, as I pointed out in the review, the 1997
Uniform Building Code Section 1914.3.5 requires smaller spacing than what you are showing. I have
attached a copy of that section. Lets not hold up the building permit process with this, but get me an
addendum back before the contractor needs to place concrete.
Thanks, Val
1997 UNIFORM BUILDING CODE
permitted to reduce the resulting computed moments in such pro-
portion that the absolute sum of the positive and average negative
moments used in the design need not exceed the value obtained
t from Formula (13-3).
1913.7.7.5 Distribution of moments at critical sections across the
slab -beam strip of each frame to column strips, beams and middle
strips as provided in Sections 1913.6.4, 1913.6.5 and 1913.6.6
shall be permitted if the requirement of Section 1913.6.1.6 is satis-
fied.
SECTION 1914 -WALLS
C_
1914.0 Notations.
Ag = gross area of section, square inches (mm2).
f c = specified compressive strength of concrete, pounds per
square inch (MPa).
h = overall thickness of member, inches (mm).
k = effective length factor.
k = vertical distance between supports, inches (mm).
Me, = cracking moment 5 VfJ 'C19/y, (For SI: 0.42 f '-Ig/yd
for regular concrete.
M„ = nominal moment strength at section, inch pound (N -m).
M„ = factored moment at section, inch pound (N -m). See Sec-
tion 1914.8.3.
Pnw = nominal axial load strength of wall designed by Section
1914.4.
P„ factored axial load at midheight of wall including tribu-
tary wall weight.
P ratio of nonprestressed tension reinforcement.
pb = reinforcement ratio producing balanced strain condi-
tions. See Formula (8-I).
= strength -reduction factor. See Section 1909.3.
1914.1 Scope.
1914.1.1 Provisions of Section 1914 shall apply for design of
walls subjected to axial load, with or without flexure.
1914.1.2 Cantilever retaining walls are designed according to
flexural design provisions of Section 1910 with minimum hori-
zontal reinforcement according to Section 1914.3.3.
1914.2 General.
1914.2.1 Walls shall be designed for eccentric loads and any lat-
eral or other loads to which they are subjected.
1914.2.2 Walls subject to axial loads shall be designed in accor-
dance with Sections 1914.2, 1914.3 and either Section 1914.4 or
1914.5.
1914.2.3 Design for shear shall be in accordance with Section
1911.10.
1914.2.4 Unless demonstrated by a detailed analysis, horizontal
length of wall to be considered as effective for each concentrated
load shall not exceed center -to -center distance between loads, or
width of bearing plus four times the wall thickness.
1914.2.5 Compression members built integrally with walls shall
conform to Section 1910.8.2.
1914.2.6 Walls shall be anchored to intersecting elements such as
floors or roofs or to columns, pilasters, buttresses, and intersecting
walls and footings.
CHAP. 19, DIV. II
1913.7.7.4
1914.4
1914.2.7 Quantity of reinforcement and limits of thickness re-
quired by Sections 1914.3 and 1914.5 shall be permitted to be
waived where structural analysis shows adequate strength and sta-
bility.
1914.2.8 Transfer of force to footing at base of wall shall be in ac-
cordance with Section 1915.8.
1914.3 Minimum Reinforcement.
1914.3.1 Minimum vertical and horizontal reinforcement shall
be in accordance with Sections 1914.3.2 and 1914.3.3 unless a
greater amount is required for shear by Sections 1911.10.8 and
1911.10.9.
1914.3.2 Minimum ratio of vertical reinforcement area to gross
concrete area shall be:
1. 0.0012 for deformed bars not larger than No. 5 with a speci-
fied yield strength not less than 60,000 psi (413.7 MPa), or
2. 0.0015 for other deformed bars, or
3. 0.0012 for welded wire fabric (plain or deformed) not larger
than W31 or D31.
1914.3.3 Minimum ratio of horizontal reinforcement area to
gross concrete area shall be:
1. 0.0020 for deformed bars not larger than No. 5 with a speci-
fied yield strength not less than 60,000 psi (413.7 MPa), or
2. 0.0025 for other deformed bars, or
3. 0.0020 for welded wire fabric (plain or deformed) not larger
than W31 or D31.
1914.3.4 Walls more than 10 inches (254 mm) thick, except base-
ment walls, shall have reinforcement for each direction placed in
two layers parallel with faces of wall in accordance with the fol-
lowing:
1. One layer consisting of not less than one half and not more
than two thirds of total reinforcement required for each direction
shall be placed not less than 2 inches (51 mm) or more than one
third the thickness of wall from exterior surface. _
2. The other layer, consisting of the balance of required re-
inforcement in that direction, shall be placed not less than 3/4 inch
(19 mm) or more than one third the thickness of wall from interior
surface.
1914.3.5 Vertical and horizontal reinforcement shall not be
spaced farther apart than three times the wall thickness, nor
18 inches (457 mm). Unless otherwise required by the engineer, I
the upper- and lowermost horizontal reinforcement shall be
placed within one half of the specified spacing at the top and bot-
tom of the wall.
1Y14,J.b vertical reinforcement need not be enclosed by lateral
ties if vertical reinforcement area is not greater than 0.01 times
gross concrete area, or where vertical reinforcement is not re-
quired as compression reinforcement.
1914.3.7 In addition to the minimum reinforcement required by
Section 1914.3.1, not less than two No. 5 bars shall be provided
around all window and door openings. Such bars shall be extended
to develop the bar beyond the comers of the openings but not less
than 24 inches (610 mm).
1914.3.8 The minimum requirements for horizontal and vertical
steel of Sections 1914.3.2 and 1914.3.3 may be interchanged for
precast panels which are not restrained along vertical edges to in-
hibit temperature expansion or contraction.
1914.4 Walls Designed as Compression Members. Except as
provided in Section 1914.5, walls subject to axial load or com-
2-141
P• 1
Transmission Result Revort(MemorvTX) ( Jun•12. 2002 11:45AM) '
1)
2)
Date/Time: Jun.] 2, 2002 11:43AM
File Page
No -.Mode Destination Pg(s) Result Not Sent
-------------------------------------------------------------------------------'---------------------
4064 Memory TX 912083447203 P• 2 OK
----------------------------------------------------------------------------------------------------
Reason for a ror -
E.1) Hans u or line fail E.2) Busv
E.3) No answer E.4) No facsimile connection
IM
M
m TmMw vadum n
c:bevuanymr
en.:. Mte Nrzrnm
Ilw um. SbM BTatiai w )CRrk Msa:e ype mmy
oawne ❑IWllatiav ow.,.eeweerrt :I:laaaahTgT omlazaaac, :a
•aaawu T.. IlEo--f. v:9e m9¢Ie. alpard taab[e rtviaw. Na tWl
UnSdm awa,o Cafe 6etlw:lot/.35:alarte matergny'g TnMl:a y�x: m dKKN:q. I iwe
a5aawpa cyy Atlii ae6wf Uia m[MaWe:e atibry Panne pux�wlT my EUlPa ma an
eJlaWm ledhSaiellwmta�rmatlemµ mom.
ThNo Vel