BUILDING INSPECTION SEQUENCE
Type of Inspections: For on-site construction, from time to time the building official, upon
I holder or his a9pni shill MR A of 8AU 9 to b6 w�ad� ��y �e�essary
Orove aportion oI tk e -construction as completed or shall notify
theerm.11pholder or his agent wherein the same fails to comply with this Code.
1. LAYOUT' L8t C6?66r,s slaked, shaking in place for building, prior to excavation:
2. FOOTING' COMMOMly made offer pales or piers are set or trenches or basement
areas are excavated. Forms and horizontal reinforcing tied in place,
vertical reinforcing cut and on job site or tied in place.
3. FOUNDATION INSPECTION.
The foundation inspection shall included excavations for thickened slabs
intended for the support of bearing wolfs, partitions, structural supports or
equipment and special requirements dor wood foundations. All forms and
reinforcing steel, etc., shah be in place.
4. PLUMBING, MECHANICAL AND ELECTRICAL:
Rough inspection: Commonly made prior to covering or concealment,
before fixtures are sed, and prior to framing inspection.
5. TRUSS INSPECTION:
Inspections of tresses.
6. FRAME INSPECTION.6
Commonly made after the roof, all framing, firestopping, draftstopping and
bracing are in place and after the plumbing, mechanical and electrical
rough inspections are approved. (Electrical inspection performed through
State of Idaho Electrical Bureau)
7. LATH'AND/OR WALLBOARD 1NSr_DECTiQN:
Commonly made after all bathing and/or wallboard interior is in place, but
before any blaster is applied, or before wallboard joints and fasteners are
taped and finished.
S. FINAL PLUMBING ASND HEATING INSPECTION-
All
systems in place, fixtures yet, ready for occupancy
9. SIDEWALK INSPECTIONS:
After forms are set, prior to placing concrete,
0. FINAL INSPECTION:
Commonly rade after the building is completed and ready for occupancy
11. QCC�JPAI�CY PERMIT.
Issued when, on final inspection, building is ready to occupy.
12. OTHER INSPECTI-ONS:
In addition to the tailed inspections above, the building department may
make or require any other inspections to ascertain compliance with this
code and other laws enforced by the building department.
INSPECTION CARD
The permit holder or his agent shall post the inspection record on the job site in an accessible
and conspicuous place to allow the bul , Iding official to mike the required entries. The record
shat be maintained by the Permit holder unt�f the final inspection has been made and approved.
have read the above and will comply in my requests for inspections by giving 24 HOUR
NOTICE prior forinspections to be made.
Electrical: 624-3767 Bulldir�g: 359-3��0 ex 326 or 313
Plumbing: 359-302Q ex 326 o� �1111i 3 or 359-3034
Signature: