HomeMy WebLinkAboutDOCS - 02-00025 - BYUI Hart Bldg - RemodelCITY OF REXBURG
BUILDING INSPECTION SEQUENCE
Type of Inspections: For on-site construction, from time to time the building official, upon
notification from the permit holder or his agent, shall make or cause to be made any necessary
inspections and shall either approve that portion of the construction as completed or shall notify
the permit holder or his agent wherein the same fails to Comply with this code.
1. LAYOUT: Lot corners staked, staking in place for building, Pr ior to excavation:
2. FOOTING,. Commonly made after poles or piers are set or trenches or basement
areas are excavated. Forms and horizontal reinforcing tied in place,
vertical reinforcing cut and on job site or tied in place.
3. FOUNDATION INSPECTION:
The foundation inspection snail included excavations dor thickened slab
intended for the support of fearing wads, partitions, structural supports, or
equipment and special requirements for wand foundations. All forams and
reinforcing steel, etc., shall be in place.
4. PLUMBING, MECHANICAL AND ELECTRICAL:
Rough inspection: Commonly made prior to covering or concealment,
before fixtures are set, and prior to framing inspection.
5. TRUSS INSPECTION:
Inspections of trusses.
6. FRAME INSPECTION:
Commonly made after the roof, all framing, firestopping, draftstopping and
bracing are in place and after the plumbing, mechanical and electrical
rough inspections are approved, (Electrical inspection performed through
State of Idaho Electrical Bureau)
7. LATH AND/OR WALLBOARD INSPECTION:
Commonly made after all lathing and/or wallboard interior is in place, but
before any plaster is applied, or before wallboard joints and fasteners are
taped and finished,
8. FINAL PLUMBING AND HEATING INSPECTION:
All systems in place, fixtures set, ready for occupancy
9. SIDEWALK INSPECTIONS:
After forms are sea, prior to placing concrete.
10. FINAL INSPECTION:
Commonly made after the building is completed and ready for occupancy.
11. OCCUPANCY PERMIT:
Issued when, on final inspection, building is ready to occupy.
12. OTHER INSPECTIONS:
In addition to the called inspections above, the building department may
make or require any other inspections to ascertain compliance with this
code and other laws enforced by the building department.
INSPECTION CARD
The permit holder or his agent snail past the inspection record on the job site in an accessible
and conspicuous place to allow the building official to make the required entries. The record
shatl be maintained by the permit holder unfi! the final inspection his been made and approved.
i have read the above and will comply in my requests for inspections by giving 24 HOUR
NOTICE prior for inspections to be made.
Electrical: 624-3767 RHil d i n n _- iqc) -.q, n 9 n Px 39 6 n .11:'4
Plumbing: 359-3020 ex 326 or 313 or 359-30334 4 11
�Y
Signature:
0 . Inc.
0'rmond Bulidersir
General Contractom - Construct -ion Management n Project Development
To: Date: Jul 30, 2002
City of Rexburg Subject:
P.O. Box 280 BYU Idaho
Rexburg, Idaho 83440-0280 Hart Fitness Center
Rexburg, Idaho
Attention: Bill Hamlin, Mechanical Ins tor
Attached
Via:
[I Under Separate Coyer
1084 N. Skyline Dave
Idaho FPI, 183402-1 76,E
Mailing A dr:
P.O. Box 1814
Idaho Falls, ID 83403-1814
Ph'8) 524-1422
Fax: (208) 524-7488
These are transmitted as checked below:
Remarks:
Response Date.
Submitted per Baur July 29r X002 request.
Copies t:
P
I A_jswo
9-1
Signed: �
Resubmit copes for approval
Submit copies for distribution
Returned
John Norton
abject Manager
Arizona 111161 -Idaho 11936 AAA 1,Montan 34498 -Oregon 66688 -Utah 93 263697 5501 -Washington ORMONBI088GL Myornin
For ApprovaI
For your use
For review and comment
X As Requested
For Pricing
For Signature &Return
x
Remarks:
Response Date.
Submitted per Baur July 29r X002 request.
Copies t:
P
I A_jswo
9-1
Signed: �
Resubmit copes for approval
Submit copies for distribution
Returned
John Norton
abject Manager
Arizona 111161 -Idaho 11936 AAA 1,Montan 34498 -Oregon 66688 -Utah 93 263697 5501 -Washington ORMONBI088GL Myornin
go