HomeMy WebLinkAboutCONCRETE TEST 39 - The Grove at Thomson FarmsFile name:
20001SB071321CRC
8D6938DA-5977-44D8-8C1A-9289702F4B03 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
13.5
Project Name:
The Grove
Test Location:
North valley gather of building number 4
Client:
Stillwater Equity Partners
Admixtures:
MP 322, MA AE 90
Ticket Number:
278068
Contractor:
Kevin Virgin Construction
Supplier:
Walters Ready Mix
Mix Number:
192
Date:
6/15/2021
Cylinder Log #:
329
Field Test Results:
Set #:
1
Slump
(inches):
2.2
Slump
Maximum
(in):
Entrained Air
(%):
3.80
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
61
Unit Weight
(PCF):
142.57
Tested By:
Y. Kabwika
Date:
6/15/2021
Picked Up By:
Yannick Kabwika
Date:
6/15/2021
Time:
9:15 AM
Max, Min Temperature
84.2; 49.1
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/22/2021 4.00 12.56 57740 4597.13 3000 Type 3
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 7/13/2021 4.00 12.6 63,725.0 5057.5 3,000.0 Type 6
C 28 7/13/2021 4.00 12.6 74,935.0 5947.2 3,000.0 Type 4
D 28 7/13/2021 4.00 12.6 69,840.0 5542.9 3,000.0 Type 6
Second Break Average:
5515
Date:
07/13/2021
Reviewed By:
E. Vail
Signature: