HomeMy WebLinkAboutENGINEERING CALCS - 03-00079 - The Meadows - Four 4-plexesDesign Intelligence, LLC Engineering Calculations Summary Date: October 1, 2003 Subjects. Lamboreaux Apartments, Madison County, Idaho Customer: Lamboreaux ConstrLictimon Abstract This analysis uses the, Design Criteria required by the local jurisdiction and the M C 2 0 00 as the basis for the calculations. Materials: Dimensional Limber —NDS 1997 design values Concrete: 2500 psi @ 2$ days Reinforcing Steel - #4 and smaller Grady 44, #5 and larger Grade 60 Assumptions: IBC 2000 — Foundations designed for Max Brg Pressure of 1500 psf increased dor depth Design Loads: Roof Live Lead (min) — 20 psf during construction Ground Snow load = 50 psf, Roof Snow load— 35 psf Snow Load importance Factor -- 1 _a Snow Exposure Factor — U.9 Wind — 90 mph, Exposure B Wind Importance Factor — 1. 0 Wind Exposure — B Seismic Desi. Category — D I Se1sM1*c Use Group - I References: HBc 2000 Trus) dist MacMillian Design Guides Summary: All beam sizes and fooling sizes ars noted on the d-raNvings. These calculations and ir�cluded details are for this location and customer only and not to be reused in any manner without the written consent of Design IntelXiaence. Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 Design Parameters Snow Load: Snow Loads rise Run Roof Pitch 3 12 Roof Pitch 4 12 Roof Pitch 6 12 Roof Pitch 7 12 Roof Pitch 8 12 Roof Pitch 10 12 Roof Pitch 12 12 Wind -Design Wind Speed Importance Factor Exposure 35 psf 90 mph 1 B LAMBREAUX APTS MADISON COUNTY IDAHO Reduction - - 0.0',psf 0.0'',psf ......................... Simplified Method Section 1609.6 Applicable loads are shown in bold letters. Horizontal Loads End Zone Transverse 1W all Roof < 512 5.1 2 Longitudinal 12.81 17.8! 14.4 12.8 2.5 psf 3.8 psf 5-1. psf 7.4 .: psf 9.4: psf,._ nwt 35.0 32.5 31.2 29.9 27-6 25.6 �Wtallior851Roof _4�_ 6.7 -4.7 11.9 -2.61 9.911 11.5 7�.9 -6.7, 8.51 -41 i psf psf psf psf psf psf Dsf i _ Vertical Loads - - -- _ � i _ __ :End Zone Interior Zonae Winward Overhang Transverse 'Windward ;Leeward Windward Leeward - ­_ --- I i End Zone Interior Zone Roof Roof 1 -1 Roof Roof 5:1 2 1 5.41 -8.8 -1 0.7 1 -6-8 -21.6 -1 6.9 512 15.4 -10.7! 10.7-1 -8.1 -21.61 16.9 > 5-1 2 5.6;-8.8 � 4.81 -7.5,, -5.1 -5.8 Longitudinal -15.4 -8.81 -10.7 6.8' -21.6 -1fi.9 ­- Maximum Horizontal Wall Loads Transverse 'Zon6 _� - ..-�- 11E 4E 1T - 4; < 5:12 9.8 -7.5- 7.2 -5.8- 5:12 12.1 -10.1 8.8 -7.5 10.7 9.1 -0.6 Page 1 10,11/2003 DeSign Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 LAMBREAUX APTS MADISON COUNTY IDAHO longitudinal 9.8 -7S _ 7.2' 5.81 Component and Cladding Design Wind-Pre'ssure'-s--­T­-ab1e 160-9'--- .6.2.1(2) Roof Zone Area �< 5:12 5:12 > 5:12 1; 201,E 10 -14.10 101 2 1p.: 1� 1 �3I - 113 3 6 13.8 50110! -13-12.51 1012.5 -12.8 1 100'1'10-13.3 10�12.1 12. 1 -12.11 10 -24.41 10 -28.2 2 20 10 _2i 8r 101 -25.6;: -. -- 2 50 10 � -18 4 � 10 -22.1 2 100 10 -35.8, 10. -19.5 3 10 10 -36.8 10 -28.2 3 20 10' 30.5r. 10 -25.6 3 50, 10 -22.1 10 -22.1 3 100' 10 -15.8 70 -19.5 i-- Wall --- 10'; m m 14.6 13.9 13 13.3. 13! 12.5 12.1 13.3 13 12.5 12.1 -17 -16.3 --15.3 -14.6 -17 -16.3 -15.3 -14.6 100' 12.4 13.6' 4 5 10 14.6' -18.5 5' 20;13.9 -18.2 5' S0' 13 -16.5 5! 100 � - 12.4! 15.1 Roof Overhang Component and baddingDesi n Wind Pressures Tab -le 160_-9.Z6.2-. -(3-) - - Zone Area -< 5:12 -- � 5:12 > 5:72 2 161 -21 -2721 -24.7 2, 20 -20.6 -272 41, - = 2 2 50 -20.1 -27 _ 2 - 3 70101 ', -79.8 -27.2 222. � -34.6 -45.7,.-24.71 -- 31 _ 20! -27.1 -40.5 _ -24 3 501 -17.3 -3 3.6 -23 3 100' -10 -28.4 -22.2..... i �) � _1609.6.2.1 4 Height and Exposure Adjustment Coefficient. - 1 -i Page 2 10/1/2003 It Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 Seismic Reference Code 1113C 2000 1615.1.2. (1) 1615.1.2(2) 1615.1 1615.1 Fa FV -- - S5 SI Site Class A - Hard Rock LAMBREAUX APTS MADISON COUNTY IDAHO Values for Ss, S1, Fa and Fv are taken from Code Control GD using Zip Code 0.606 g 0. 193 g 51te Lass b - Dense Soil or Soft R Site Class C - Stiff Soil Site Class D - Soft Soil Fa 0.8 1 1.2 1.32 Fv 1615.1.2 SMS FSite Class 0.4848; 113 C D A -- - 0.606_ 0.7272 0.79992' 1615.1.2 SMI = FvS1 0.15441 0. 193 0.3281 0.39179': Design S.Pectral Resp Accel - - -� F, 615.1.3 SDS = 2/3*SMS 0.3248161 0.40602 0..487224 0.535946 SDI = 213*SM I 0.1034481 0.12931 , 0.219827 0.262499 1616,.2 Seismic Use Group 1616.3 Seismic Design Category! Group f -Non-Essential Table 1-6-16.3- (1) D � Table 1616..3(2) D Seismic Response Coefficient (Table 1617_6 Response Modification Factor R = g 1616.2 (Table 1604.5) Occupancy 1m____ portance Factor I = � Basic Fundamental Period I Ct Steed Moment Resisting Frame 0.(335 Reinforced Concrete Moment Resisting Frame Q.03 All ether Building Systems � 0,42 ouuuing neigrn 3/ ttITable 1617.4.2 Cu = Onnrnvim4n Ci....l.........._i uHua� r iUr i �ctr rei r�c� Ta W Ct*hn"3/4 - - --- --- 0,39 sec I Ri-qid Bldg Site Class Cs = SDSi(R11) = Max Cs =SDI/(R/I)T = Min Cs = 0.044SDS*l Design Seismic Pr_Ls "s 0 0.0541 0.-0677 0.0068.' 0.0143 1.31 0.0144 0.0179- 0.0214 9M re 0.0236 10/1/2003 Design Intelligence, LLC 3.685 W Hwy 33 Rexburg, Idaho 83440 Site Class CS = LAMBREAUX APTS MADISON COUNTY IDAHO B 1 0.01431 C 0.0179 D 0.02.14 1617.4.1 Equiv Lateral Force Method 9-V = CsW 0-0236 W 1617.5.1 Simplified Approach-, --V =--1.2*(SDS/R)*W - 0.10719;W Determine - Method of Seismic Analysis Light Framing Construction Criteria, 2308.2.1, Building stories 2308.2.2 Bearing wall floor to floor height 2308.2.3.1 Average DL 2308-2.3.2 Floor Live Loads 2308.2.3.3 Ground Snow Load 2308.2.4 Wind speed -3 -9 15 40 0.0236 stories YES ft -- YES._ psf YES P'sf IYES psf YES mph XES 2308.2.5 Truss Span 40 ft Cy�S 1 61 6.6.1 Simplified Analysis Requirements 1. Does wilding meet light frame construction crite r! a ? 2. Is building of any other construction with flexible diaphragms at every level as defined in section 1 602 Building may use Simplified Analysis Method am YES YES 10/1 /2003 Design Intelligence, LLC LAMBREAUX APTS 3685 W Hwy 33 MADISON COUNTY Rexburg, Idaho 83440 IDAHO Type Fb psi—Fdpsi E psi LVL 1 2600 2851 19:00000, GL -13 2400 190 18000001 DF 1 1300 95. Annnn Beam I Floor and Wall Support Type Fb psi I GLB 2400 Span = I Tributary A Loads Fv psi IE psi _ IWIj 1800000 OHUVV oo psf Uniform Load = 385Ibs/ft Live Load 40 psf I 440 Ibs/ft Dead Load 15 psf � i 165 Ibs/ft Moment 0 lbs Live Load�Moment= 264001b -ft 316800 lb -in Dead Load Moment Section Modulus Required 5280'ilb-ft = 63360j1b-in .. 158.40 an 3 - ._�� .. Section VVIUM :D.izo in. Section Depth = 15 in -' - Section Modulus Provided Moment of ineri#ia Provided 1 92.2 in3--r 1441.4 in4 - _ Deflection _ _ _ � _. S Live Load = 0.24 in. -i Dead Load = 0-09 in. Total 0.34 in. Horizontal Shear fv = 155 psi ;OK FtI 218.5 psi Allowable U360 TL/24p Use 5.125 10K Reaction = Page 1 15 IGLB 79201 lbs 10/1/2003 Design Intelligence, LLC 3685 W Hwy 33 rn -- -I- - - 6 g I LAMBREAUX APTS MADISON COUNTY Page 2 101112003 Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 Type Fb psi Fv PSI E psi I L LAMBREAUX APTS 10/1/2003 MADISON COUNTY IDAHO LVL 2600! 2$5�9000001 GILB 2400� 190 1800000; DF I 13001 95 1900000. Beam 4 :,Second Floor Headers Type Fb psi Fv psi E psi LVL 2600 285 1900000 Span 4 ft I - Tributary Area 17.5 ft � �I LOaas I Point Load Snow 0 psf Uniform Load - Live Load 40 psf Dead Load 15 psf j , Moment Live Load Moment = 1400 Ib -ft Dead Load Moment= 525,Ib-ft Section Modulus Required Section Width = 3.5 in." Section Depth = 9.5 in. Section Modulus Provided Moment of In ritia Provided - flti _ _ Live Load Dead Load = Total = 0.00 lin. o.00 -in. 8.88 in3 -27.6 in3 250.11 1 in4 Horizontal Shear fV _ � 87 psi OK FV = _ .--285 psi Allowable Use U360 16800 lb -in 6300TIb-in 0 lbs. OIbs/ft 7001bs/ft 262.5 lbs/ft 0.13 lin. 10K L/240 0.2 in. --[—OK (Reaction 1925 lbs 3.5 x 9w5 LVL Design Intelligence, LLC 3685 W Hwy 13 Rexburg, Idaho 83440 Shear Wall Ana (Wind Load Roof Height Wall Heiaht LAMBREAUX APTS MADISON COUNTY IDAHO lysis Short Wall 22 psf 7.ft �� 18ft --i Length of Long Wall = 64 ft Area at Mid Height of Wall = 1024,ft^2 Wind Force 225281 Ibs Shear Wall Length 70 ft Shear/ft in Wall -- @ Mid Height 3221 lbs/ffit .. Provide 112, APA rated sheathing with 8d nails at 4 ox. at pan -el edges and 12" ox. in the field. Blocking is required. Seismic Analysis �, 12 MOO an_=us Long Wall Length Short Wall Length Wall Dead Load --]Seismic MuItiplier 0.107 'Width ;Length iLoad 39 68 24 64 ft ides Snow) 35 ft I � --- Height I Length Load 18 198 15 `. Seismic Force @ Mid Height of Wall Weight 63648,Ibs Weight 26730 lbs 9670IIbs _� � Shear Wall Length 70 ft Shear per. ft in Wall @Mid Height 138 lbs/ft OK Provide 1/2" APA rated sheathing with 8d nails at 4" o4c. at panel edges and 12" o.c. in the field. Blacking is reauired. i � Wage I 10/,1/2003 1 h'ae=r Business TJ-BeamUM) 6.0.E serial Number: User, 1 10/1/2003 3-32:46 PNI Page 1 Engine Version: 1.5.1 Second Floor Joists 9 1/2" TJ1@/Pro(TM)=150 @ 1611 o/c THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED LOADS: Analysis is for a .Joist Member. Primary Load Group - Residential -- Living Areas (p : 40.0 Live at 10 % duration, 1 .0 Dead SUPPORTS. Input Bearing Vertical Reactions I) Detail Other Width Length Live/Dead/u P ift/Tota I I Stud wall 3.50"' 2.25 it 320 196101416 A: Rim Board 1 Ply 1, 1/4" 0.E TJ -Strand Rim Erd Stud wall 3.50" 2.25" 320 / 96 / 01416 AI Rim Board 1 Ply 1/" E TJ -Strand Rim Board -See Tj PE I FI E ' / BUILDERS GUIDE for detail(s): . :Flim Board DESIGN CONTROLS: Shear Obs) Vertical Reaction (lbs) Moment (Ft -Lbs) Lige Load Defl (in) Total Load Deft (ire) TJPr Maximum Design Control Control 402 -396 7120 Passed (35°/a) 402 402 1076 passed (4(3%) 1163 1 183 2839 Passed (41 %) 0-125 0.290 Passed (U999+) 0.162 0.579 Passed {U857} 48 30 Passed Location Int. end Span I under Floor loading Bearing 2 under Floor loading MID Span 1 under Floor loading IIID Span 1 under Floor loading MILS Span I under Floor loading Span 1 -Deflection Criteria: STANU I LL:U480,TL-. . -Allowable moment nt was -increased for repetitive member usage. -Deflection n I i is based on composite action with single layer of 19/32", /" Panels '' PnRating) LUES & NAILED wood decking. r ng (Lu : All compression edges (top and bottom) must be braced at 2'8" o1c unless detailedotherwise. Proper attachment and positioning f 'lateral bracing is required to achieve member stability, TJ -Pro RATING SYSTEM -ThTJ-Pro Rating System value provides ad d itis n al floor performance infrma tionn - �� d � �d n LEC 1`�l.I.LE� � !�'�", �' Panels „ an tin dlln The controlling spar i supported li Additional r�idrat{ � ��n �r this rating include: : �� �n - None. structural analysis of the deck has not been performed by the program. Comparison Value: .36 ADDITIONAL NOTE : -IMPORTANT! The analysis presented is output from software developed Trus J6 t be (TJ). TJ warrants the sizing of it products by this software will accomplished in accordance with Td product din criteria and codeted �d t p dire values.Thspecificproduct ppii�tior�, input design #o ads, d dimensions n have been provided b the mer user. This output has not been revs` a -Not all products are readily available. Check with your supplier r T technical _ . . rprrtti fir prdutilb�l�t. -THIS ANALYSIS FOR TTS JOIST PRODUCTS QALY! PRODUCT SUBSTITUTION VOIDS THIS aiL.I. -Allowable tr Design methodology a useci for Building Code UBC analyzingh TJ Di tribudonr � dut IItd above. PROJECT INFORMATION. it Lamoreaux Apartments CoPyright 0 2002 by Trus Joist, a Weyerhaeuser Business Tj and 'LTJ -Scam are registered trad�marks oz Trus jojSt.. e_1 Joist'"r Prow and TJ -Proms' are trademarks CE Trus joist- OPEFZATOR INFORMATION: TJ-Beam(TM) 6.05 Salol Number, Users 1 1011120 03 3:32: 7 P Second Ffor alt 9 1/2" TJ1@1Pro(TM)=150 @ 16" o/c Paget Engine Version: ,.5.,2 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED Load Groups Primary Load Group Max.ert-ical Reaction Teal Max.rtical Reaction Live Selected Bearing Length (�r Max. UrLbraced Legg th Loading on all spans, Design Shear Ub ) .Max Shear (lbs) Meter Reaction (lbs) Support Reaction Ubs ) moment (Ft -Lbs) Live Deflection (ire) Total Deflection (in) Loading on all Design Shur (1 ) Max Shear (lbs) Member Reaction (lbs) uppert Reaction (lbs) Moment Ft -L]) PROJECT I F i TI N: Lamoreaux Apartments A 11-1 7.00"T lbs) 416 4T6 I ) 320 320 .. () 2.25(W) 32 LIDF _ x,00 a Dead + Floor 396 -396 402 -402 402 402 416 416 1163 0.125 0.162 F Dead only 1 -1 93 -93 93 93 96 96 268 Copyright 0 2002 by Trus joist f a Weyez.-haeuser Business T `ff) alld TJ -Seam's are regi-,�;tet i d trademarks of Trus Joist. e- I Joi t'w, Prol`° and TJ -Pro'" are trademarkf Taus Joist. OPERATOR INFORMATION: