HomeMy WebLinkAboutRESCHECK - 03-00065 - Hyde Park II - Eleven 4-Plexes Bldg 16-18, 30-37a REScheck Comphance Certificate 1995 SEC RES checkSoflware Version 3.5 Release 1 c Data filename: Untitled.rck TITLE: Hyde 'ark CITY: Rexburg STATE: Idaho HDD -0, 8+93 CONSTRUCTION TYPE: Single Family DATE: 05 / 131 03 PROJECT INFORMATION: Phase #2 COMPANY INFORMATION: Futures of Idaho, Inc. COMPLIANCE: Passes Maximum UA. = 122 Your Home UA = 112 8.2% Better, Than Cade (UA) Ceiling 1: Flat Ceiling or Scissor Truss Wali I.: W -0.0d Frame, 16" O.C. Window 1: Vinyl Frame:Double Pane with Low -E Door l : Solid Bailer 1: Gas-fired Steam, 80 AFUE Permit Number Checked By/Date Gross Glazbig Area or C.ty Cont. or Door qtr -Value -Value -Factor UA 720 44.0 0.0 864 23.0 0.0 57 240 19 31 0.340 19 0.]80 43 COMPLIANCE STATEMENT: The proposed building design described here i*s consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed buildmg has been designed to meet the 1995 MEQ requirements in RE5checkVersian 3.5 Release I c (formerly MECchec� and to comply with the mandatary requirements listed in the RES check Inspection Checklist. _ /? / I / BuilderfDesigner. Date 5�/3 D 3 RIEScheck Inspection Checklist 1995 MEC RES checkSoftware Version 3.5 Release 1 DATE: 05/13ro3 TITLE: Hyde Park Bldg. I Dept. j Use Ceilings: 1. Ceiling i Flat Ceiling or Scissor Truss, R-44.0 cavity insulation Comments: f � Above -Grade Wails: [ ] � 1. Wali 1: Wood Frame, 16" o,c., R-23.4 cavity insulation E Comments: � Windows: j ] j 1. Window 1-.'V* nyl Frame:Double Pane with Low -E, U -factor: x.340 j For windows without labeled U -factors, describe features: j # Panes— Frame Type Thermal Break? Yes [ } No � Comments: � Doers: 1. Doer 1: Solid, U -factor: 0.180 j Comments: � Heating and Goofing Equipment: 1. Boner 1: Gas -Fired Steam, 80 AFUE or higher � Make and Model Number fi � Air Leakage: [ ] ! points, penetrations, and all other such openings i.n the building envelope that are sources of air � leakage must be sealed. [ ] � Recessed lights must be 1) Type IC raked, or 2} installed imide an appropriate air -tight assembly � with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must beinstalled with a � 3" clearance From insulation, � Vapor Retarder: [ � j Required on the warm -in -winter side of all non -vented framed ceilings, wails, and floors. � Materials Identification: � ] � Materials and equipment must be identified so that compliance can be determined. [ � � Manufacturer manuals for all installed heating and cvolmg equipment and service water heating � equipment mush be pravided. ] J Insulation R -values, glazing U -factors, and heating equipment efficiency must be clearly marked an l the building plans or specifications. Duct Insulation: [ ] � Ducts in unconditioned spaces must be insulated to R-5. � Ducts outside the building must be insulated to R-8.0. } � Duct Construction., � ] � All duds must be sealed with mastic and fibrous backing tape_ Pressure -sensitive tape may he used � for fibrous ducts. Duet tape is not permitted. The HVAC system must PrOvIde a rneans fog- balancing air and water systems. Temperature Cantrols: Thermast,ats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut offthe heating and/Or coolincy inpui to each zone or floor shall be provided. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swfil"ing pools must have an oiVoff heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 120 T or chilled fluids below 55 T must be insulated to the I levels in Table 2. Table I.- Minimum Insulation Thicknessfor Circulating Hut Water Wipes. Insulation Thkkness 1"n Inches by Pipe Sizes Heatnd water Non -Circulating Runouts Circulating Mains and Runouts Temperature 170-184 140-160 1+DU-130 Table 2: Minorum Nping system T es Heating systems Low Pressure/Temperature Low Temperature Steam Condensate (for feed wafer) Cooing Systems chilled Water, Refrigerant, and Brine 1.5" to .0" Over " 1.5 2.0 1.0 1.. 5 0.5 1.0 ess for "C Pipes. Fluid Temp. Insulation Thickness Inchesbj Size Lan .2e ( F) 2 " Runouts V and Less 1.25" to 2" 2.5" to 4?T 201-250 1.0 1.5 1.5 2.0 120-200 0.5 I.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.s 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Z'