HomeMy WebLinkAboutRESCHECK - 03-00065 - Hyde Park II - Eleven 4-Plexes Bldg 16-18, 30-37a
REScheck Comphance Certificate
1995 SEC
RES checkSoflware Version 3.5 Release 1 c
Data filename: Untitled.rck
TITLE: Hyde 'ark
CITY: Rexburg
STATE: Idaho
HDD -0, 8+93
CONSTRUCTION TYPE: Single Family
DATE: 05 / 131 03
PROJECT INFORMATION:
Phase #2
COMPANY INFORMATION:
Futures of Idaho, Inc.
COMPLIANCE: Passes
Maximum UA. = 122
Your Home UA = 112
8.2% Better, Than Cade (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
Wali I.: W -0.0d Frame, 16" O.C.
Window 1: Vinyl Frame:Double Pane with Low -E
Door l : Solid
Bailer 1: Gas-fired Steam, 80 AFUE
Permit Number
Checked By/Date
Gross Glazbig
Area or C.ty Cont. or Door
qtr -Value -Value -Factor UA
720 44.0 0.0
864 23.0 0.0
57
240
19
31
0.340 19
0.]80 43
COMPLIANCE STATEMENT: The proposed building design described here i*s consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed buildmg has been designed to meet the 1995 MEQ
requirements in RE5checkVersian 3.5 Release I c (formerly MECchec� and to comply with the mandatary requirements listed in
the RES check Inspection Checklist. _ /? / I /
BuilderfDesigner.
Date
5�/3 D 3
RIEScheck Inspection Checklist
1995 MEC
RES checkSoftware Version 3.5 Release 1
DATE: 05/13ro3
TITLE: Hyde Park
Bldg. I
Dept. j
Use
Ceilings:
1. Ceiling i Flat Ceiling or Scissor Truss, R-44.0 cavity insulation
Comments:
f
� Above -Grade Wails:
[ ] �
1. Wali 1: Wood Frame, 16" o,c., R-23.4 cavity insulation
E Comments:
� Windows:
j ] j 1. Window 1-.'V* nyl Frame:Double Pane with Low -E, U -factor: x.340
j For windows without labeled U -factors, describe features:
j # Panes— Frame Type Thermal Break? Yes [ } No
� Comments:
� Doers:
1. Doer 1: Solid, U -factor: 0.180
j Comments:
� Heating and Goofing Equipment:
1. Boner 1: Gas -Fired Steam, 80 AFUE or higher
� Make and Model Number
fi
� Air Leakage:
[ ] ! points, penetrations, and all other such openings i.n the building envelope that are sources of air
�
leakage must be sealed.
[ ] � Recessed lights must be 1) Type IC raked, or 2} installed imide an appropriate air -tight assembly
� with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must beinstalled with a
� 3" clearance From insulation,
� Vapor Retarder:
[ � j Required on the warm -in -winter side of all non -vented framed ceilings, wails, and floors.
� Materials Identification:
� ] � Materials and equipment must be identified so that compliance can be determined.
[ � � Manufacturer manuals for all installed heating and cvolmg equipment and service water heating
� equipment mush be pravided.
] J Insulation R -values, glazing U -factors, and heating equipment efficiency must be clearly marked an
l the building plans or specifications.
Duct Insulation:
[ ] � Ducts in unconditioned spaces must be insulated to R-5.
� Ducts outside the building must be insulated to R-8.0.
}
� Duct Construction.,
� ] �
All duds must be sealed with mastic and fibrous backing tape_ Pressure -sensitive tape may he used
�
for fibrous ducts. Duet tape is not permitted.
The HVAC system must PrOvIde a rneans fog- balancing air and water systems.
Temperature Cantrols:
Thermast,ats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut offthe heating and/Or coolincy inpui to each zone or floor shall be provided.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools: All heated swfil"ing pools must have an oiVoff heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 120 T or chilled fluids below 55 T must be insulated to the
I levels in Table 2.
Table I.- Minimum Insulation Thicknessfor Circulating Hut Water Wipes.
Insulation Thkkness 1"n Inches by Pipe Sizes
Heatnd water Non -Circulating Runouts Circulating Mains and Runouts
Temperature
170-184
140-160
1+DU-130
Table 2: Minorum
Nping system
T es
Heating systems
Low Pressure/Temperature
Low Temperature
Steam Condensate (for feed wafer)
Cooing Systems
chilled Water, Refrigerant,
and Brine
1.5" to .0" Over "
1.5 2.0
1.0 1..
5
0.5 1.0
ess for "C Pipes.
Fluid Temp. Insulation Thickness Inchesbj Size
Lan
.2e ( F) 2 " Runouts V and Less 1.25" to 2" 2.5" to 4?T
201-250
1.0
1.5
1.5
2.0
120-200
0.5
I.0
1.0
1.5
Any
1.0
1.0
1.5
2.0
40-55
0.5
0.s
0.75
1.0
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Z'