HomeMy WebLinkAboutCOMCHECK - 03-00058 - The Village Apartments - Buildings #1-7Envelope Comp
2000 IECC
Hance Certificate
Pcmt Number
Checked By/Date
COMcheck-.�L 5ari�var�e u er��ul� �.�+ ����v��4 �U
Data filename; C:\DOc,=ents and SettingslWelisl+Rexburg-cam checklTheVillage-Rexburg, ID Bldg-l.cc
Section 1.: Project Information
Project dame:
DesigneriContractm:
Document Author:
Nates:
The V*11arge Apartments
Building # 1
Glenn Wells, ,AIA, Architect
JMfLVV
Submitted to City of Rexburg, Idaho
Section 2*0 general Information
BuildinaLocation (for weather data):
Climate Zone;
Heating Degree Days (bass 65 degrees F):
Coaling Degree Days (base, GS degrees F).6
Building Tv
Multifamily
A
Q
Rexburg, Idaho
16
8693
143
Floor Area
Project Description (check ane):
New Construction � addition � AhUati011 , Uiconditioned Shell (File Affidavit)F�
Section 3: Requirements Checklist
Bldg.
Dept.
Use
Air Leakage, Component Certification, and Vapor Retarder Requirements
1. All joints and penetrations are caulked, g
asketed weather -shipped, or otherwise seated,
Z, Windows, doors, and skylights certified as meeting leakage requirements,.
3. C'nmponent R -values & U-faCtOTS labeled as certified'.
4. Vapor retarder installed.
Co.RAmflremeents
m anent NainelDes��� tion�'
Roof 1: All -Wood Joist'Rafter/Truss
Exterior Wall 1: Wood Frame, Any Spacing
Window 1: Vinyl Frame, Double Pane with Low -E
Ctear, 4
Donr 2, Solid
]Floor 1: Unheated Slab -On -Grade, Vertical 3 ft.
Gross Cavity dont. Proposed DU get
Area R. -Value RaValueU.Factor U -Factor
3668 30.0 30.0 0.01! 0.047
7,632 19.0 19.0 0.030 0.067
ivy
0.460 0.520
0,400 0.11
2 53 •-• ---
328 ---
(a) Budget U -factors areused for -
sc)ftxare baseline, calculations ONLY, yard are not code rear
Envelope PASSES-: Design 29% better than code
Sectioia 46 Compiian�� S"'tatement
The proposed envelope design represented "in this document is consistent with the building plans, specifications and
other calculations subrrutted with this permit application, The proposed envelope system has been designed t -o meet
the 20()o JECC requirements in COMcheck-PLVersion �.4 Rebase 2baYl� to comply �xrith the mandatory
requirements in the Requirements Checklist.
principal Envelope Designer -Name
ignature
date
Envelope Compliance Certificate
2000 IECC
Pelt Number
Checked BY/Date
CO [I Ailea5e zb
Data filename: CADocuments and Settings\Wells'\4-Re-xburg-cic)m check\TheVillage-Rexburg, [D Bldg-2.cck
Section 1:,Project Information
t
Project Name
Designer/ContTactor:
Document author:
Nates:
The Village Apartments
Building # 2
Glenn Wells, AIA, Architect
J�14lrLN1F
Submitted to City of Rexburg, Idaho
Section 2:6 General Information
Building Location (for weather data) -..3,
Climate Zone:
Heating Degree Days abase 65 degrees F):
Cooling Degree Days abase 65 degrees F):
Bw'lding T�
Multifamily
W,
Rexburg, Idaho
16
86-93
143
Floor Area
Project Description (check one):
New Construction � Addition � AlteTation. � Unconditioned Shell (File Affidavit)
Section 3,*, Requirements Checklist
Bldg.
Dept.
Use
Agar Leakage, Component Certification., and Vapor Retarder Requirements
All joints and penetrations are caulked, Basketed, weather-stripped., or otherwise sealed.
windows, doors, and skylights certified as meeting leakage requirements.
Component R -values & U -factors labeled as certlffliEd.
Vapor retarder installed.
I.
2.
.
4
11r.Sr M a t
P %�O%�XXAMk _MLV6%0%j'hF&JLx , * X & %For & & %o %..r
-
`..o=onent a.MC)Bescript10_n_
Roof I: ASI -Wood Joist/Rafter/Truss
Exterior Wali 1: Wood Frame, Any Spacing
Window l.: Vinyl Frame, Double Pane with Low -F,
Clear, SHGC 0.37, PF 0,37
Door 2: Solid
Floor 1: Unheated Slab -fin -Grade, Vertical 3 ft:
Grass Cavity Cont. Proposed Budget
Area 'I-Va�ue �-Value aclor t - f I+
6435 30.0
30.0
0.017
0.047
11122 19.0
19.0
0.030
0.067
1128 ---
---
0.500
0.520
378 --_
__
0.200
0.112
522 ---
10.0
---
---
(a) Budget U -factors ars used for soffivare bu5ehnc ca[QuiatM5 ONLY, and are i7vt G4de requirements.
Envelope PASSES: Design 28% better than. cads
2
Section 4: Compliance Statement
The proposed envelope design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this pemut application. The proposed envelope system has been designed to meet
the 2040 1ECC requirements in COMcheck-.E.Z Version. 2.4 Release 2b and to comply with the mandatory
requirements in the Requirements Checklist.
Principal Envelope Designer -Name Signature Date
Permit Number
Envelope Compliance Certificate Checked By/Date
2000 IECC
VMf'MI...4
Data filename: C:\Documents and Settings\We11s\+Rexburz-ccm checklTheVillage-Rexburg, ID Bldg-3.cck
Section 1: Project Information
Protect Name,: The Village Apartments
Building # 3
Designer/Contractor: Glenn Fells, AIA., Architect
Document Author. ,iMlLW
Notes: Submitted to City of Rexburg, Idaho
Section 2: General Informatioll
Building Location (for weather dada):
Climate Zany:
Heating degree days abase 65 degrees. F)-,
Cooling Degree Dais (base 65 degrees fl:
Rexburgjdaho
16
8693
143
BU1'1dM',o.r Tvpe___ Floor Area
Multifamffly 94b8
Pro'F
ject Description (check one):
New Construction Addition � Alteration � Unconditioned Shell (File Affidavit)
Section 3: Requirements Checklist
Bld&
Dept,. �
Use �
� Air Leakage, Component Certification, and Vapor Retarder Requirements
[ � �
1. All joints and penetrations are caulked, Basketed, weather-stripped, or otherwise sewed.
[ ] � 2. Windows, doors, and skylzahts certified as meeting leakage requirements.
[ ] � 3. Component R -values & U -factors labeled as certified.
[ 1 � 4. Vapor retarder, installed.
�f..fRequirements
Com�onent Name/Descripti011
Roof 1: All -Wood Joist/Rafter/Truss
Exterior Wail }: Wood Frame, Any Spacing
Window I -, Vinyl Frame, Double Pane with Low -E
eleAr, 9ECC Q.179 PF 0.1i
Door 2: Solid
Floor 1: Unheated Slab -fin -Grade, Veztical 3 ft.
Gross
Cavity
Cont.
Proposed
Area
R -Value
R -Value
U -Factor
3668
30.0
30.0
0.017
7632
19.0
19.0
0.03-0
Budget
U -Factor
0.047
0.067
16,0 --. �i3 0.460 0.110
252 --- --- 0.400 0.112
328 --- 10.0 --- ---
(a) Bud t U - factors are used for software baseline calculatio, and are not code requirements.
ns ONLv,
Envelope PASSES: Design 29% better than code
Section 4: Cornpfianu-,; Statement
The proposed envelope design represented in this document is consistent with the building plans, specif cations and
other calculations submitted with this perniit application. The proposed envelops system has been designed to meet
the 2�Q0 �ECaC requirements in COMcheek-EZ Version 2.4 Release 2b and to comply with the mandatory
requirements in the Requirements Checklist.
Principal Envelops Designer -Name Signature Date
Envelope Compliance Certificate
200-0 IECC
Penrr�t Number
Checked By/Date
COMcheck-EZ 8dtware Version 1.4 Release lb
Data filename; C:1Documents and SettingslWellsl+Rexburg-cora checklTheVillage-Rexburg, ID Mdg-4.cck
Section 1: Project Information
Project Name F
DesignerlCantracfor:
The Village Apartments
Building # 4
Glenn Wells, AIA, Architect
Document Author: PAIME701
Notes: Submitted to City of Rexburg, Idaho
Section 2: General hiformation
Building Location (dor weather data); Rexburg, Idaho
Climate done: 16
Heading Degree Days abase 55 degrees F)o 9693
Cooling Degree Days abase 65 degrees F): 143
Building Type Floor Area
Multifamily 13348
Project Description (chick one):
New Construction Addition � Alteration _ Unconditioned Shell (Fide Affidavit)
Section 3: Requirements Checklist
Bldg. j
Dept..
Use �
� Air Leakage,. Component Certiffeation, 2nd Vapor Retarder Requirements
[ � � 1. All joints and penetrations are caulked, gasketed, Breather-stripped, or otherwise sealed,
� ] �
2. Windows, doors, and skylights certified as meeting leakage requirements.
[ ] � 3, Component R -values & U -factors labeled as certified.
[ ] �
4. Vapor retarder installed.
natatil-s"Oviffle 'Poniiiremenfq
Component_ Name/Description
Roof 1: All -Wood Jolst/Rafter/Truss
Exterior Wall I; Woad Frame, Any Spacing
Window 1: Vinyl Frame, Double Pane with Law -E
Clear, SHGC 0.37, PF x.37
Doer 2: Solid
Floor 1 : unheated Slab -On -Grade, Vertical 3 ft.
Cross
Cavl'ty
Cont.
Proposed
Budget
Area
R -Value
R-ValueU-Factor
CJ -Factor
6435
30.0
30,0
.0.017
0.047
11122
19.0
19.0
0.030.
0.067
1128
---
---
0.500
0.520
379
---
___
0.200
0.112
522
10.0
---
Budget U -factors are used for sours baseline calculations ONLY, andare not code requirements.
Envelope PASSES: Design 2$%better than code
SAa-A- - 4 -
Section 4: CompfiallCe t' Lt'P':'MIEIRL
The proposed envelope design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this permit application. The proposed envelope system has been designed to meet
the 2000 IECC requirements in COMcheck-EZ Version 2.4 Release 2b and to comply with the mandatary
requirements in the Requirements Checklist,,
Principal Envelope Designer -Name
Si*gnatue
Envelope Compliance Certificate
2000 IECC
Perrmt Number
Checked By/Date
COMcheck-EZ Sofmare Version 2.4 Release 2b
Data filename: C:\Documents and SettingslWe11sl+Rexbuxg-tarn checklTheVillage- Rexburg, ID Bldg-5.cck
Section 1: Project Information
Project Name:
The Village Apartments
Building # 5
Glenn Wells, AIS, Architeci
Document .�iu�i.ar: JWJfl..W
Notes: Subn-iitted to pity of Rexburg, Idaho
Section �: General Information
Building Location (for weather data): Rexburg, Idaho
Climate Zone: 16
Heating Degree Days (base 65 degrees F): $b93
Cooling Degree Days (bass 65 degrees F}: 143
Buil&&Type Floor Area
Multifanu-1y 13488
Project Description ;check one);
New Construction _Addition � Alteration � Unconditioned Shell (File Affidavit)
Section 3: Requirements Checklist
Bldg.
Dept.
Use
Air Leakage, Component Certification, and Vapor Retarder Requirements
1, All joints and penetrations are Gawked, gasketed, wether. -stripped, or otherwise sealed,
2. Windows, doors, and skylights certified as meeting leakage requirements,
3, Component R -values & U --factors labeled as certified.
4. Vapor retarder installed.
%—,o A ILL I" ,,. spec;ric equirilmp.rjtS
CoMponent Name/Description
Roof I-, All -Woad Joist/Rafter/Truss
Exterior Waft I : Wood Frame, any 'pacing
Window 1: Vinyl Frame, Double Pane with Low -E
Clear, SHGC Q.37, PF 0.37
Door 2: Solid
Floor 1: Unheated Slab -On -Grad, Vertical 3 ft.
Gross
Cavity
Cont,
Proposed
Budget
Area
R. -Value
0.067
1608 ---
R -Value
U -Factor
0.520
U
-Factor
0.200
7130 30.0
30.0
0.017
0.047
12083 19.0
19.0
0.030
0.067
1608 ---
---
0.500
0.520
335 ---
---
0.200
0.112
531 ---
10.0
---
---
(a) Budget -factors are used. for software baseline calculations ONLY, and are not code requirements.
Envelope PASSES: Desip 26% better than code
-M o
Section : mpiian
The proposed envelope design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this perrm't application. The proposed envelope system his been designed to meed
the 2000 IECC requirements in COMcheck-EZ Version 2.4 Release 2b and to comply with the mandatary
requirements in the Requirements Checklist,,
Principal Em7elope Designer-NameSignature Date
Envelope C ompliance Certificate
2000 IECC
Permit dumber
Checked By/Date
COMcheck-EZ Software Verson 2.4 Release 2b
data filename: C:\Documents and Setdngs\We11s\+Rexburg-c.om checklTheVi11age-Rexburg, ID 131dg-6.cck
Section 1,:;, Project Information
Project Name:
Designer/Contractor'.
The Village Apartments
Building # 6
Glenn Wells, AIA, Architect
Document Author; WLW
Notes: Submitted to City
Section 2; General Information
wilding Location (for weather data):
Climate Zane:
Heating Degree Days abase GS degrees F):
Cooling Degree Days (base 65 degrees F):
Buil4ajz Type
Multifarnffly
of Rexburs, T .an,
Project Description (check ons):
New Construction Addition Alteration
Section 3,* Requirements Checklist
Bldg.
Dept.
Use
Rexburg, Idaho
16
8693
143
1 or A rp
]1794
.� Unconditioned Shell (File ,Affidavit)
Air Leakage, Component Certifleaflon,and Vapor retarder .Requirements
1 , All faints and penetrations are caulked, gasketed, weather-stripped, or otherwise sealed.,
2. Windows, doors, and skylights certified as meeting leakage requirements.
3. Component R -values & U -factors labeled as certified.
4. Vapor retarder installed,
Climate-Specificuirem nt
Component Name/Description
Roof I.- All -Wood Joist/Rafter/Truss
Exterior Wall 1: Woad Frame, Any Spacing
Window I - Vinyl Frame, Double Pane with Low -E
Clear, SHGC 0.37y PF x,37
Door 1: Solid
Floor I.-, Unhealed Slab -fin -Grade, Vertical 3 fit.
Gross
Cavity
Cont,,
Proposed
Budget
Area
R -Value
R -Value
U -Factor
U -Factor
X979
30.0
30.0
4.417
0.04?
9G84
19.0
19,E
4.430
0.067
851
420
416
m_�
rf f
0,460
0.2(3b
(a) B -factors are used for software bascl'necalculations ONLY and are not code r it nts.
Envelope PASSES: Design 29% better than cede
Sect-l'ou" r:CotIIPXAan%,,,TStatemmei"I'Ll
_-Irw
The proposed envelope design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this pernut application. The proposed envelope system has been designed to meet
the 2000 T T- 4' CC requirernMts in COMcheck-EZ Version2.4 Release Zb and to comply with the mandatory
requirements in the Requirements Checklist..
Principal Envelope Designer -Name Sianature
Date
Envelope Compliance Certificate
2000 IECC
COMcheck-EZ Software Version 2.4 Release 2b.
Pemait Number
CheckeylDate
Data filename: CADocurnents and SeWngs\We11s\+Rexbur9-com checklTheV1'11age-Rexburg, ID BldgwTcck
Section 1: Project Information
Pro Ja
Name:
Des igner/Contractor'-,
l-cent� thor
Notes.
The Village Apartments
Building # 7
Glenn Wells, AIA., Architect
JM/LW
Submitted to City of Rexburg, Idaho
Section 2: General Information
Building Location {fog weather data}:
Climate done:
Heating Degree days (base 65 degrees F):
Gaoling Degree Days (base 65 degrees F):
Rexburg, Idaho
16
8693
143
Buildin&Type Floor Area
Multifarm'IY 94G8
traject Description (check ane):
New Construction � Addition, � Alteration � Unconditioned Shell (File Affidavit)
Section 3: Requ0
irements Checklist
Bldg.
Dept.
Use
Air Leakage, Component Certification, and Vapor,Retarder Requirements
J.. All points and penetrations are caulked, Basketed, weather-stripped, or otherwise sealed.
2, Windows, doors, and skylights certified as meting leakage requirements.
3. Component R -values & U -factors labeled as certified.
4. Vapor retarder installed.
19 11� ,7 Op
Climate -Specific Requirements
Component Name/Description
Rauf 1: All -Wood Joist/Rafter/Truss
Extei-ior Wall 1: Wood Frame, Any Spacing
window I .- VinylFrame, Double Pane with Low -E
Clear,
SHGC D.37, PF 0.3?
Door 2: Solid
Floor 1: Unheated Slab -On -Grade, Vertical 3 ft.
Grass
cavity
Cont.
Proposed
Budget
Area
R -Value
R -Value
U -Factor
U -Factor
3668
30.0
30,0
0.0I7
0.047
7632
19.0
19.0
0,430
0.067
560
252
32$
0.460
0.400
�.M`M
(a) Budget U -factors are used for soffivare baseline calculations ONLY,and are not code requirements.
Envelope PASSES: Design 29% better than code
Section4ve xSt a 'Ll ri I a e, n tv
0.520
0,112
__w
The proposed envelope design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this penmlt application. The proposed envelope system has been designed to meet
e 2000 IIECC requirements in COMcheek-EZ Version 2.4 Release 2b and to comply with the mandatary
requirements in the Requirements Checklist*
Principal Envelope Designer -Name
Signature
Date