Loading...
HomeMy WebLinkAboutRESCHECK - 03-00044 - 336 & 340 Eagle Summit - Twin HomeREScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release I d Data filename.- iJntiEled.rck PROJECT TITLE: Sainsbury CITY: Rexburg STATE: Idaho HDD.- 863 CONSTRUCTION TAPE: Single Family DATE: 08125!43 PROJECT DESCRIPTION: lot 15 eaglewoad COAPLIANCE: Passes Maximum. UA = 618 Your Home UA = S IQ 17.5% Better Than Code (UA) Ceiling ], :Flat Ceiling or Scissor Truss Wall I : Wood Frame, 24" a C. Window 1 : Vinyl Frame -Double Pane with Low -E Door I: Solid Door 2: Glass Basement Wali 1: Solid Concrete or Masonry Wall height: 8.4' Depth below grad: 7. 0' Insulation depth-, 8.0' Window 2: Vinyl Frame- Double Pane with Low -E Furnace I : Forced Hot Air, 90 AFLTE Permt Number Checked By/Date Gross Glazing Area or Cavity Cont, or Door Perimeter R -Value R -Value U -Factor UA 3363 40.0 0.0 98 2691 19.0 4.0 140 2*L3 0.340 i2 40 0.350 14 60 0.350 21 2392 11.0 0.0 147 52 0_350 18 COMPLIANCE ST,ATIEMENT: The proposed building design described here is consistent with the budding pians, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2044 IECC requirements in RE.S cheekVersian 3.5 Release I d (formerly ME,C check} and to comply with the mandatory requirements listed in the RES check Iz�spectic�n checklist. Builder/Designer Date pity of Rexburg Building Department Jon Berry 12 North C enter Street Rexburg, Idaho Alan hook Sainsbury Construction 4697 N. Haroldsen Dr. Idaho Falls, Idaho ie: Pian corrections Lot 1 "") Mr. Berry Tharp you for faxing the information, the fallowing corrections are being made: 1. Stock components will supply the details and infQrmation requested. 2. Stack components will redesign the truss system to cor.�ply with the fire walk requirements. 3. The floor system design wi11 be provided per the TH expert from the supplier. 4. We propose to add 4 alternate braced wail panels in the back wall. There will be 5/811 anchor bolts installed an each side of bay with HD5A holddowns bolted to (3) framing members and straps installed at the operfl�ngs. I will brig the truss details and floor detail to 11�an you Alan Don Cook 757-9254 529-4510 you as soon as possible., I REScheck Compliance Certificate 2000 IECC RES eireck5oftware Version.' .5 Releas Ia. �� Data filename: Unto#led.rck TITLE: TOWN -HOME CITY: Idaho Fills STATE: Idaho NIDD: 7918 CONSTRUCTION TYPE; Single Family DATE: 0 8/2 1 /03 DATE OF PLANS: 8/15/03 PROJECT INFORMATION: LOT 15, BLOCK 1, EAGLE WOOD DIVISION #1 COMPANY INFORMATION: SAINSBURY CONSTRUCTION 4697 N. HAROLDSEN DR. IDAHO FALLS, IDAHO 83401 COMPLIANCE: Passes Maximum UA = ?82 Your Home UA = 632 19.2°fa Better Than Code (CTA) Ce*t- Flat i*1 Si'Truss Wall L, Wood Frame, 24" . . Basement Fall I : Solid Concrete or Mason Wall height: 8.01 Depth below grade: Tff Insulation depth: 8,OT Window 1: Vinyl Frame:Dvubfe Pane with Low -E Door I : Solid � Door.): Glass "'� ° Furnace ! : Forced Hai Air 9� XFUE Air Conditioner 1: Electric r SEER Permit Number ,zap Necked By/Date Grass Glazing Area or Cavity Cont- or Dear Perimeter R -Value E -Value L7 -Factor UA 3382 /11L 0. 0..0 3376 19.0 0.0 2800 11.0 0.0 84 132 98 199 141 0.34 119 0.35 29 4.35 46 CQNiPi.,IANCE STATEMENT: The proposed, building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IE C requiretnents in RE'ESeheekVersivn .'3,5 Release la (formerly MEecheek) and to comply with the mandatary requirements listed in the REScheckinspection Checklist. ou &ilder/Designer 6�- REScheck Inspection Checklist 2000, !ECC RES ch-eekSoftware Version 3.5 Release I a DATE: 08121!03 TITLE: TOWNHOME Bldg. J Dept. � Use � Ceilings: L � � I . Ceiling 1; Flat Ceiling or Scissor Truss 5 R-40.0 cavity insulation Comments: � Above -Grade Walls: C � � 1. Wail I : Wood Frame, 24" o .c_, R-19.0 cavity insulation � Comments: � Basement Walls: � ] � i. Basement Wall I: Solid Concrete OrMasonry, 8.0'ht/7_O'bg/8.01 insul, � R- 1 I. 0 cavity in s ulation � Comments: i � Windows: [ ) J 1. Window 1: Vinyl Frame:Double Pane with Low -E, U -factor: 0.340 � For windows without labeled U -factors, describe features: � Y" Panes Frame Type_. Thermal Break? Yes [ j No f Comments: 1 r � Dvors: C � � I. Door L. Solid, U' -factor.- 0.350 � Comments: 2. Door 2: Glass, U' -factor: U.350 � Comments: j Heating and Cooing Equipment: [ j J 1. Furnace l :Forced Hot Air, 9.0 AFUE or higher � Make and Model Number [ � � 2. Air Conditioner 1: electric Central Air, 10 SEER or higher j Make and Model Number i J Air Leakage: [ ] J Joints, penetrations, and all other such openings in the building envelope that are sources of air � leakage must be sealed. E ] j Recessed fights must be J.} Type IC rated, or 2} installed imide an appropriate, air -tight assembly J with a 0.5" clearance from combustible materials, if non -IC rated, the fixture must be installed with a f 3" clearance from insulation. f Vapor Retarder: [ ] { Required on the warm -in -winter side of all non -vented framed ceilings, walls, and Mors,, 1 � Materials Identification: [ ] � Materials and egtaipmen# must he installed in accaraanco with the "Aculuj'dw1ureT's installation instructions. Materials and equipment must be identified so that compliance can be determined. [ ] � Manufacturer manuals for all installed heating and cooling equipment and service water heating � equipment must be provided. g � i Insulation R -values, glazing U -factors and heating equipment Uipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation. [ ] � Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] j A1l joints, seams, and connections Must be securely fastened with welds, gaskets,. mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). � ] � Ducts shall be supported every 10 feet or in accordance with the manufacturer"S [ � � Cooling ducts with exterior insulation, must be covered with a vapor retarder. [ ] j Air filters are required in the return air system. I � The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] � Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] � inlet'Water heaters with vertical pipe risers must have a heat trap on both the and outlet unless, the water heater has an integral heat trap or is part of a circulating system. [ � � Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ � � Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ � { A I I heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulati 9 an: L ] � HVAC piping conveying flu -ids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minhnum Insulation ThjCA-nessf0'r Circulating H ot W a, er P,pes. Insulation Thickness in Inches bv Pine Heated Water Tem erature (F) 170-184 144-1b4 100-130 Non-Cr-culati Runauts Up to 1.25" I.0 0.5 0.5 Table ?: AIanirnuM .Insulation Thickness for HVA C Pipm Fluid Temp, Pi*pingSystem Types Range F Heating Systems Low PressurelTemperatu:re Low Temperature Steam Condensate for deed water) Coling Systems chilled Vater. Refrigerant., and Brine Sizes �ircu�atin� Mains and Runo-uts Insulation Thickness in i Sizes 2" Runouts I" and Less 1.25" 11 � � 4r' 201-250 1.0 1.5 L5 10 120-2200 . 1 ■ 1.0 1.5 Any Lo 1- 1 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 l.5 1.5 NOTES TO FIELD (Building Department Use Only)