HomeMy WebLinkAboutRESCHECK - 03-00038 - 425 W 5th S - RemodelREScheck- Compliance Certificate 1995 MEC REQ checkSaftware Version 3.5 Release I c Data filename.- Untitled.rck CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Multifamily DATE: 0-6/16/03 COMPLIANCE: Passes Maximum UA = 152 Your Home UA =X45 4.6% Better Than Code (UA) Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 6.Q' InsuIation depth: 9.0' Window 1: Vinyl Frame;Dauble Pane with Low -E Window 2: Vinyl Frarne:Double Pane with Low -E Basement Wail 2: Solid Concrete or Masonry Wall height: 9.0' Depth below grade.- 6.0' Insulation depth: 9.D' Basement Wali 3 : Solid concrete or Masonry Wadi height: 9.0' Depth below grade: 6.0' Insulation depth: 9_0' Window 3: Vinyl, Frame:Double Pane with Low -E Door 1 Solid Door : Solid Basement Wall -. Solid Concrete or Masx)nry Wall.height: 9.01 Depth below grade:6.01 I Hain .tion depth: 9_0T Permit Number Checked By/Date Gress Glazing. Area or Cavity Cont. or Door Perimeter R -Value R ­Value U- Factor UA 936 13.0 16 0.500 8 16 0.350 6 216 13.0 3.6 11 936 13.0 3-6 47 16 0.500 81 21 11 0.160 11 21 0.160 3 216 13.0 3-6 11 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building pans, specifications, and other calculations submitted with the permit application. T7�e proposed building has been designed to �anect the 1995 MEC requirements in REScheckVersion 3.5 Release 1c (formerly -MECclaec� and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer Date RIEScheck Inspection Checklist 1995 ME�' ��lIVl�l,Ik��l`IUdP� V�Y5�6ii �.� �elease lc DATE: 06116103 Bldg. dept. f Use � � Basement Walls: � ) � 1. Basement Wall 1-. Solid Concrete or Masonry, 9.0'ht/6.0'bg/9.0'i,nsu1, � R-13.0 cavity + R-3.6 continuous insulation � Comments: [ � j 2. Basement Wall 2: Solid Concrete or Masonry, 9.0' htl6.0' bg/9.01 insul, � R- 13. 0 cavity + R-3.6 continuous insulation � Comments: 3. Basement. Wall 3: Solid Concrete or Masonry, 9.0'ht/6-O'bg/9.0'insu1, � R-1 3.0 cavity + R-3.6 continuous insulation � Comments: [ J � 4. Basement Wall 4-- Solid Concrete or Masonry, 9.0'ht/6.0'bg/9.0'insul, � R-13.0 cavity + R-3.6 continuous insulation # Comments: � Windows, I. Window 1: Vtriyi Frame: DoublePane with Low -E, U-faetor: 0.500 � For windows without labeled LJ -factors, describe features: j #Panes Frame Type- Thermal Break? Yes No � Comments: [ } � 2. Window 2: Vinyl Frame:Double Pane with Law -E, U-faclor: 0.350 � For windows without labeled U -factors-, describe features: � #Panes Frame Type Thermal Break? [ ] Yes No Comments: [ ] � 3. Window 3: Vinyl Frame:Double bane with Low-E,,,U-factor: 0_500 � For windows without labeled U -factors, describe features: j #Pangs Frame Type Thermal Break? [ ] 'Y'es No f Comments: � Doors: 1- Door 1: Solid, U -factor: 0.X60 J Comments-. � ] � 2. Door 2: Solid, U -factor: 0. 160 .I Comments: ! Air Leakage; [ ] j ]dints, penetrations, and all other such openings in the building envelope that are sources of air � leakage must be sewed. [ � J Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly � with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a � 3" clearance from insulation, Vapor Retarder: [ � j Required an the warm -in -minter side of all non -vented ftamed ceilings, walls, and floors. j Materials Identification; Materials and equipment must he identified so that compliance can be determined. [ ] j Manufactures manuals for all installed heating and cooling equipment and service water heating j equipment must be provided. ] � Insulation R -values and glazing U -factors must be clearly marked on the building plans or specifications. Duct Iasulatioa: ] j Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction. ] J All ducts must be scaled with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous ducts. Duct tape is not permitted, ! ��� ��� �����M M. q - 1 1. 1-f 8VIA �or�alancing air anj water sys ems., Temperature Controls. Therniostats are required for each dwelling unit (non -dwelling areas must have one thermostat for each system or zone). A manual or automatic means to partially restrict or shut off the heating andVor cooling input to each room shall be provided - Electric Systems: ] J Separate electric meters are required for each dwelling unit. Circulating Hot Water Systems: � � Insulate circulating hot water pipes to the, levels in Table 1. 0 Swimming Pvvls: J � All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool. pumps require a time clock. Heating and Coollong Piping Insulation: HVAC piping G41nYP&j?� � �Gve�c i4� '�4kfe 2. ��� �'' pj p4jUPO Ouids below 55 OF must be insulated to the Table minimum Insulatiot, Thieknessfor Circulating Hot Neater Pipes. Insulafion Thickness in Inches bv Pipe Heated Water Tem F 17a -iso 140-160 100-1-310 Non-Circulat'Ipg Runouts up to 1 „ 0.5 0.5 0.5 LJ2 to 1.25" 1.0 0.5 0.5 Circulating 1.511 to 2.01, 1.5 1.0 0.5 Sizes Niains and Runouts Over 2'0 2.0 1.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches Piping System T es Ran e F Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (for feed water Cooling Systems Chilled Water, Refrigerant, and Brine " Run outs 1 " and Less ipe �. Sizes 1.2511 to 211 2.511 to. V 201-250 1.0 I.5 1.5 2.0 120-200 0.5 1.0 1.0 1.5 Any 1,0 1.0 1.5 2.43 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 I.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only),