HomeMy WebLinkAboutRESCHECK - 03-00038 - 425 W 5th S - RemodelREScheck- Compliance Certificate
1995 MEC
REQ checkSaftware Version 3.5 Release I c
Data filename.- Untitled.rck
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Multifamily
DATE: 0-6/16/03
COMPLIANCE: Passes
Maximum UA = 152
Your Home UA =X45
4.6% Better Than Code (UA)
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 6.Q'
InsuIation depth: 9.0'
Window 1: Vinyl Frame;Dauble Pane with Low -E
Window 2: Vinyl Frarne:Double Pane with Low -E
Basement Wail 2: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade.- 6.0'
Insulation depth: 9.D'
Basement Wali 3 : Solid concrete or Masonry
Wadi height: 9.0'
Depth below grade: 6.0'
Insulation depth: 9_0'
Window 3: Vinyl, Frame:Double Pane with Low -E
Door 1 Solid
Door : Solid
Basement Wall -. Solid Concrete or Masx)nry
Wall.height: 9.01
Depth below grade:6.01
I Hain .tion depth: 9_0T
Permit Number
Checked By/Date
Gress Glazing.
Area or Cavity Cont. or Door
Perimeter R -Value R Value U- Factor UA
936 13.0
16 0.500 8
16 0.350 6
216 13.0 3.6 11
936 13.0 3-6 47
16 0.500 81
21 11
0.160 11
21 0.160 3
216 13.0 3-6 11
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building pans, specifications,
and other calculations submitted with the permit application. T7�e proposed building has been designed to �anect the 1995 MEC
requirements in REScheckVersion 3.5 Release 1c (formerly -MECclaec� and to comply with the mandatory requirements listed in
the REScheckInspection Checklist.
Builder/Designer
Date
RIEScheck Inspection Checklist
1995 ME�'
��lIVl�l,Ik��l`IUdP� V�Y5�6ii �.� �elease lc
DATE: 06116103
Bldg.
dept. f
Use �
� Basement Walls:
� ) � 1. Basement Wall 1-. Solid Concrete or Masonry, 9.0'ht/6.0'bg/9.0'i,nsu1,
� R-13.0 cavity + R-3.6 continuous insulation
�
Comments:
[ � j 2. Basement Wall 2: Solid Concrete or Masonry, 9.0' htl6.0' bg/9.01 insul,
� R- 13. 0 cavity + R-3.6 continuous insulation
� Comments:
3. Basement. Wall 3: Solid Concrete or Masonry, 9.0'ht/6-O'bg/9.0'insu1,
�
R-1 3.0 cavity + R-3.6 continuous insulation
�
Comments:
[ J � 4. Basement Wall 4-- Solid Concrete or Masonry, 9.0'ht/6.0'bg/9.0'insul,
� R-13.0 cavity + R-3.6 continuous insulation
# Comments:
�
Windows,
I. Window 1: Vtriyi Frame: DoublePane with Low -E, U-faetor: 0.500
� For windows without labeled LJ -factors, describe features:
j #Panes Frame Type- Thermal Break? Yes No
�
Comments:
[ } � 2. Window 2: Vinyl Frame:Double Pane with Law -E, U-faclor: 0.350
� For windows without labeled U -factors-, describe features:
� #Panes Frame Type Thermal Break? [ ] Yes No
Comments:
[ ] � 3. Window 3: Vinyl Frame:Double bane with Low-E,,,U-factor: 0_500
�
For windows without labeled U -factors, describe features:
j #Pangs Frame Type Thermal Break? [ ] 'Y'es No
f Comments:
� Doors:
1- Door 1: Solid, U -factor: 0.X60
J
Comments-.
� ] � 2. Door 2: Solid, U -factor: 0. 160
.I Comments:
! Air Leakage;
[ ] j ]dints, penetrations, and all other such openings in the building envelope that are sources of air
� leakage must be sewed.
[ � J Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
� with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
� 3" clearance from insulation,
Vapor Retarder:
[ � j Required an the warm -in -minter side of all non -vented ftamed ceilings, walls, and floors.
j
Materials Identification;
Materials and equipment must he identified so that compliance can be determined.
[ ] j Manufactures manuals for all installed heating and cooling equipment and service water heating
j equipment must be provided.
] �
Insulation R -values and glazing U -factors must be clearly marked on the building plans or specifications.
Duct Iasulatioa:
] j Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction.
] J All ducts must be scaled with mastic and fibrous backing tape. Pressure -sensitive tape may be used
for fibrous ducts. Duct tape is not permitted,
! ��� ��� �����M M. q - 1 1. 1-f 8VIA �or�alancing air anj water sys ems.,
Temperature Controls.
Therniostats are required for each dwelling unit (non -dwelling areas must have one thermostat for
each system or zone). A manual or automatic means to partially restrict or shut off the heating
andVor cooling input to each room shall be provided -
Electric Systems:
] J Separate electric meters are required for each dwelling unit.
Circulating Hot Water Systems:
� � Insulate circulating hot water pipes to the, levels in Table 1.
0
Swimming Pvvls:
J � All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool. pumps require a time clock.
Heating and Coollong Piping Insulation:
HVAC piping G41nYP&j?�
� �Gve�c i4� '�4kfe 2.
��� �'' pj p4jUPO Ouids below 55 OF must be insulated to the
Table minimum Insulatiot, Thieknessfor Circulating Hot Neater Pipes.
Insulafion Thickness in Inches bv Pipe
Heated Water
Tem
F
17a -iso
140-160
100-1-310
Non-Circulat'Ipg Runouts
up to 1 „
0.5
0.5
0.5
LJ2 to 1.25"
1.0
0.5
0.5
Circulating
1.511 to 2.01,
1.5
1.0
0.5
Sizes
Niains and Runouts
Over 2'0
2.0
1.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches
Piping System T es Ran e F
Heating Systems
Low Pressure/Temperature
Low Temperature
Steam Condensate (for feed water
Cooling Systems
Chilled Water, Refrigerant,
and Brine
" Run outs 1 " and Less
ipe
�.
Sizes
1.2511
to 211 2.511 to. V
201-250
1.0
I.5
1.5
2.0
120-200
0.5
1.0
1.0
1.5
Any
1,0
1.0
1.5
2.43
40-55
0.5
0.5
0.75
1.0
Below 40
1.0
I.0
1.5
1.5