HomeMy WebLinkAboutCHECKLIST - 03-00038 - 425 W 5th S - RemodelDate:
Project: :5,ogaal4i%4- 14
r
NSPECTION CHECKLIST
Job Addre��W: t�SZ W. S� S.
Building Permit Number: t2p3—oZ-bZ
Q
The following comments based on the 200D dition of the International Residential Cade should
resolved before an Occupancy be
p Y permit is issued. This correction list is -not a building permit. the aaQrova�
of plansAnH specific�tians dogs not permit ihe violation of any section a
Code or any federal, state or focal I tion,
r
f the Intemational Residential
3-12-03
•
rb
1
OUTSI_DE
House Numbers (visible from the street)
Grade {yard is
sloped away from foundation)
1
.4
�Sidewalk & Landscape Strip 5' wide (W/ 6fl of granular borro
Front Setback coverage 60% - min green
Windows - Carvers and Screens ('shall be rale
zlo� 1
w (hill 1231)) --7' LS strip
arable or removable from the inside for egress
Window Wells min. 24.1) tear (out and above well
Z. -.Exterior Steps (? X14 " max. rise & 1011 min. tread)
Stairway Handrails 4 or more risers or over 3011 (<4" max. spacingo� uprights)
T- Guardrails (provide if over 30" above floor/grade & 411 max
{
�Landings X35" x 3G" min.,(not r� . �at the topaq f the star if
Thresholds 1 1/2)y max_ ahn�rP
�osts r
■
sphere spacing for uprightar). \
a door does not swig over stairs}
fl I ding (7:3/43) max if door
fives not swing over landing}
equired to be treated, redwood or cedar if in con#act of roncre#e f ear#h\!�, }
Roofing ono apparent leaks, installed pro
.�asonry (fintels as per table 7Q3.7, 1
�RRoaf Ventilation(asper plans}
perly and roofing as per plans)
INSIDE
Egress Doom Via!l egress doors mush beable fa a e
p n from �nsrde W1 out use of key,:s or tools)
Mmmmh�
Window Energy talc's: match actual �nrind+ov�v
_�aafe'�y Glazing provid8d in all doors, within 24" r f door arc and below �0" & ire tib e
------- hnclosvre
/.'O'Bathroom Ventilation(either,operable window or fan that vents directly to outside)
/eiSilnks, Bathtubs and Showers check heck for cau�king, operation and beaks}
�Stairway Illumination (switch at top and bottom)
Stairs (7 3/4 max. riser, 10"' m€n. triad, (nosing 314" tO '� 114" with sol[ risers
,,�Har�draiis Cant (34°' to 38", 'I 1/21, to wadi, aid gnp-� 114" to 2" dna. gpngrn � 4"Ariangular��_ space, � max)
" hand continuous, Rev'd 30" ar more above grade o� f�oar�, uprights 4'; sphere max
spacing, tnangular space 6" sphere marc spacing}
i� Garage (Dry walled and taped, firewall penetrations and electrical boxes, door to house 20 min. rated,
ducts penetrating firewall must be 26 gauge min. & not open to garage)
"Egress Windows (clear 2a" width and 24" height, 5..7.sf min. opening with 4451 max. sill height).
Smoke Detectors din each sleeping room, outside in immediate vicinity and an each story/basement-
split levels (who days}, only on upper floor --ail En#e�connected wis�thout a disconnecting switch)
foam Plastic (meets requirement of R318)
AWater Heater Anchorage over 4' with flex water conn. shallbe anchored or strapped to building)
'i�'ater Header Vent (check air flow with return in finished 'basement)
Clothes Dryer Ducts (solid metal ducts, no screws in duct & vest directly to outside)
0 ODuct Supports'(metal ductssupported 10' min spacing & nonmetal as per manus. installation instr.)
.,)<�[Duct Insulation educt in non conditioned areas shah be insulated)
Gas Line Supports spa r 10'for up #0 314„, 12' far over 1” and 6' for tubing up to 1. 1!Z'
0
El