HomeMy WebLinkAboutCONCRETE TEST 37 - The Grove at Thomson FarmsFile name: 20001SB06302021EJB 1EF43A11-BBBE-4582-87DF-3D612C105A1A 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20001 Cumulative Test Load Amount: 15.0 Project Name: The Grove Test Location: Entrance Sidewalks of buildings 4, 5, 6, and 7 Client: Stillwater Equity Partners Admixtures: MP 322, MA AE 90 Ticket Number: 278068 Contractor: Headwater's Construction Supplier: Walters Mix Number: 192 Date: 6/2/2021 Cylinder Log #: 276 Field Test Results: Set #: 1 Slump (inches): 5.5 Slump Maximum (in): Entrained Air (%): 5.70 Entrained Air Spec. (%): Concrete Temperature (°F): 66 Ambient Temperature (°F): 45 Unit Weight (PCF): 141.12 Tested By: Y. Kabwika Date: 6/2/2021 Picked Up By: Yannick Kabwika Date: 6/2/2021 Time: 9:00 AM Max, Min Temperature 80,54 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/9/2021 4.00 12.56 45855 3650.88 3,000.00 Type 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/30/2021 4.00 12.6 59,290.0 4705.6 3,000.0 Type 4 C 28 6/30/2021 4.00 12.6 59,460.0 4719.0 3,000.0 Type 1 D 28 6/30/2021 4.00 12.6 60,070.0 4767.5 3,000.0 Type 5 Second Break Average: 4730 Date: 06/30/2021 Reviewed By: W. Moffat Signature: