HomeMy WebLinkAboutCONCRETE TEST 36 - The Grove at Thomson FarmsFile name: 20001SB06292021EJB 12D1BDAC-43EF-45B6-8272-45F59A8E8E95 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20001 Cumulative Test Load Amount: 11.0 Project Name: The Grove Test Location: Left sidewalk across the street of the north side of building # 7 Client: Stillwater Equity Partners Admixtures: Ticket Number: 278068 Contractor: Headwater's Construction Supplier: Walters Mix Number: 192 Date: 6/1/2021 Cylinder Log #: 272 Field Test Results: Set #: 1 Slump (inches): 5.5 Slump Maximum (in): Entrained Air (%): 5.60 Entrained Air Spec. (%): Concrete Temperature (°F): 65 Ambient Temperature (°F): 45 Unit Weight (PCF): 140.64 Tested By: Y. Kabwika Date: 6/1/2021 Picked Up By: Yannick Kabwika Date: 6/1/2021 Time: 8:45 AM Max, Min Temperature N/A Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/8/2021 4.00 12.56 42535 3386.54 3000 Type 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/29/2021 4.00 12.6 59,500.0 4722.2 3,000.0 Type 4 C 28 6/29/2021 4.00 12.6 59,055.0 4686.9 3,000.0 Type 4 D 28 6/29/2021 4.00 12.6 61,010.0 4842.1 3,000.0 Type 4 Second Break Average: 4750 Date: 06/29/2021 Reviewed By: W. Moffat Signature: