HomeMy WebLinkAboutCONCRETE TEST 36 - The Grove at Thomson FarmsFile name:
20001SB06292021EJB
12D1BDAC-43EF-45B6-8272-45F59A8E8E95 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
11.0
Project Name:
The Grove
Test Location:
Left sidewalk across the street of the north side of
building # 7
Client:
Stillwater Equity Partners
Admixtures:
Ticket Number:
278068
Contractor:
Headwater's Construction
Supplier:
Walters
Mix Number:
192
Date:
6/1/2021
Cylinder Log #:
272
Field Test Results:
Set #:
1
Slump
(inches):
5.5
Slump
Maximum
(in):
Entrained Air
(%):
5.60
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
45
Unit Weight
(PCF):
140.64
Tested By:
Y. Kabwika
Date:
6/1/2021
Picked Up By:
Yannick Kabwika
Date:
6/1/2021
Time:
8:45 AM
Max, Min Temperature
N/A
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/8/2021 4.00 12.56 42535 3386.54 3000 Type 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 6/29/2021 4.00 12.6 59,500.0 4722.2 3,000.0 Type 4
C 28 6/29/2021 4.00 12.6 59,055.0 4686.9 3,000.0 Type 4
D 28 6/29/2021 4.00 12.6 61,010.0 4842.1 3,000.0 Type 4
Second Break Average:
4750
Date:
06/29/2021
Reviewed By:
W. Moffat
Signature: