HomeMy WebLinkAboutCONCRETE TEST 35 - The Grove at Thomson FarmsFile name:
20001SB06252021HR
274B4AC1-9D1B-4A31-BEC2-91C96F699933 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
22.0
Project Name:
The Grove
Test Location:
North sidewalk of building #6 and West sidewalk of
building # 6 started at about 25 ft from the northwest
coner of building #6, and approximately 175 ft away
from the northeast coner of building # 7 to the end the
east side sidewalk of building 7.
Client:
Stillwater Equity Partners
Admixtures:
Ticket Number:
278068
Contractor:
Headwater's Construction
Supplier:
Walters
Mix Number:
192
Date:
5/28/2021
Cylinder Log #:
267
Field Test Results:
Set #:
1
Slump
(inches):
5.0
Slump
Maximum
(in):
Entrained Air
(%):
5.90
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
63
Ambient
Temperature
(°F):
55
Unit Weight
(PCF):
139.76
Tested By:
Y. Kabwika
Date:
5/28/2021
Picked Up By:
Emma Brown
Date:
5/28/2021
Time:
9:30 AM
Max, Min Temperature
1
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/4/2021 4.00 12.56 41135 3275.08 3,000.00 Type 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 6/25/2021 4.00 12.6 61,050.0 4845.2 3,000.0 Type 4
C 28 6/25/2021 4.00 12.6 61,855.0 4909.1 3,000.0 Type 1
D 28 6/25/2021 4.00 12.6 61,495.0 4880.6 3,000.0 Type 2
Second Break Average:
4882
Date:
06/25/2021
Reviewed By:
E. Vail
Signature: