Loading...
HomeMy WebLinkAboutFOUNDATIONS - 04-00289 - 450 W Main - GarageR403.2 - TABLE R403.3 R403.2 Footings for wood foundations. Footings for wood foundations shall be in accordance with Figures R403.1(2) and R403.1(3). Gravel shall be washed and well graded. The maxi- mum size stone shall not exceed 3/4 inch (19.1 mm). Gravel shall be free from organic, clayey or silty soils. Sand shall be coarse, not smaller than 1/16 -inch (1.6 mm) grains and shall be free from organic, clayey or silty soils. Crushed stone shall have a maximum size of 1/2 inch (12.7 mm). R403.3 Frost protected shallow foundations. For buildings where the monthly mean temperature of the building is main- tained at a minimum of 64'F (IVC), footings are not required to extend below the frost line when protected from frost by in- sulation in accordance with Figure R403.3(1) and Table R403.3. Exceptions: 1. No foundation not so protected may be attached to frost -protected shallow foundations. 2. Unheated garages, porches, utility rooms and:carports shall not be permitted to be attached to dwelling units with frost -protected shallow foundation. FOUNDATIONS Materials used below grade for the purpose of insulating footings against frost shall be labeled as complying with ASTM C 578. R403.3.1 Protection of horizontal insulation below gound. Horizontal insulation placed less than 12 inches (305 mm) below the ground surface or that portion of hori- zontal insulation extending outward more than 24 inches (610 mm) from the foundation edge shall be protected against damage by use of a concrete slab or asphalt paving on the ground surface directly above the insulation or by ce- mentitious board, plywood rated for below -ground use, or other approved materials placed below ground, directly above the top surface of the insulation. R403.3.2 Drainage. Final grade shall be sloped in accor- dance with Section R401.3. In other than Group I Soils, as detailed in Table R405.1, gravel or crushed stone beneath horizontal insulation below ground shall drain to daylight or into an approved sewer system. R403.3.3 Termite damage. The use of foam plastic in areas of "very heavy" termite infestation probability shall be in accordance with Section R324.4. TABLE R403.3 MINIMUM HJRIH ATION REQUIREMENTS FOR FROST -PROTECTED FOOTINGS IN HEATED BUILDINGSa AIR FREEZING INDEX (OF-days)b VERTICAL INSULATIONR-VALUEo•e R.VALUEc,d HORIZONTAL INSULATION Along walls At corners HORIZONTAL INSULATION DIMENSIONS PER FIGURE R403.3(1) (Inches) A B C 1,500 or less 4.5 NR NR NR NR NR 2,000 5.6 NR NR NR NR NR 2,500 6.7 1.7 4.9 12 24 40>cm, 3,000 7.8 6.5 8.6 12 24 40 3,500 9.0 8.0 11.2 24 30 60 40000 10.1 10.5 13.1 24 36 60 For SI: I inch= 25.4 mm, oC = [(oF)-32]/1.8. a. Insulation requirements are forprotectionagainst frost damage in heated buildings. Greatervaluesmay, be required to meet energy conservation standards. Inter- polation between values is permissible. b. See Figure R403.3(2) for Air Freezing Index values. c. Insulationmaterials shall provide thestated minimmR-values underlong-termexposure to moist, below -ground conditions in freezing climates. The following R -values shall be used to determine insulation thicknesses required forthis application: Type 11 expandedpolystyrene-2ARperinch;Type lVextrudedpolysty- rene--4.5R per inch; Type VI extruded polystyrene -4.5R per inch; Type IX expanded polystyrene -3.2R per inch; Type Xextmded polystyrene -4.5R per inch. NR denotes "not required." d. Vertical insulation shall be expanded polystyrene insulation or extruded polystyrene insulation. e. Horizontal insulation shall be extruded polystyrene insulation. 64 2000 INTERNATIONAL RESIDENTIAL CODE FOUNDATIONS INSULATION DETAIL FLASHING PER SECTION R703.8 INSULATION PROTECTION PER SECTION R403.3. SLOPE FINAL GRADE PER SECTION R403.3.2� 121N. MIN. i NOMINAL 4IN. SCREENED AND' WASHED GRAVEL OR CRUSHED STONE, DRAINED PER SECTION R403.3.2 HORIZONTAL INSULATION PLAN For SI: I inch = 25.4 mm. IN. MAX. 00 -1 a sI o - o� FIGURE R403.3(t) SLAB -ON -GROUND FOUNDATION FLOOR PER SECTIONS R403.1 AND R506 VERTICAL WALL INSULATIONa 40RIZONTAL INSULATIONa a. See Table R403.3 for required dimensions and R -values for vertical and horizontal insulation. I FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST -PROTECTED FOOTINGS IN HEATED BUILDINGS 2000 INTERNATIONAL RESIDENTIAL CODE 65